{"title":"GE Multilin UR Series Relays","description":"\u003cp\u003e\u003cspan\u003eGE Multilin UR Series relays deliver advanced protection and control for critical power systems. These robust devices combine precise monitoring, customizable logic, and reliable fault detection to safeguard motors, transformers, and distribution networks. Engineered for durability and ease of integration, the UR family ensures enhanced safety and uptime across industrial and utility applications.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"ur600ir-flame-scanner-abb-ur600-ir","title":"UR600IR Flame Scanner ABB UR600 IR","description":"\u003ch2 style=\"color: #003366; font-weight: bold; font-family: 'Arial Black', sans-serif;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: #f0f8ff;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #003366; color: white;\"\u003e\n\u003cth style=\"border: 1px solid #003366; padding: 8px; text-align: left;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #003366; padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e🌈 Spectrum Sensitivity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eOperates effectively within a range of 0.6 to 3 µm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e🔋 Power Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eRequires 300 mW DC, powered by Uvisor series control units.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e🌡 Operating Temperature Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e-10 to 80°C (14 to 176°F) for general operation.\u003cbr\u003eMaximum of 60°C (140°F) in T6 classified areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e🌡 Storage Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eCan withstand temperatures from -40 to 100°C (-40 to 212°F).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e🔒 Enclosure Rating\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eIP66 (NEMA 4X), ensuring protection against dust and water.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e⚠️ ATEX Classification\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eEEx-d IIC T6, suitable for use in hazardous areas (ATEX category G-D).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e📜 Certification\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eCE type examination certificate number CESI 03 ATEX 151.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; font-family: 'Arial Black', sans-serif;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: #f0f8ff;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #003366; color: white;\"\u003e\n\u003cth style=\"border: 1px solid #003366; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #003366; padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e📏 Dimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e94 x 94 x 172 mm (3.7 x 3.7 x 6.8 inches).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e⚖ Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e1 kg (2.2 lbs).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e💨 Lens Cleaning Air Requirements\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eDirect View: 115 l\/min (4 SCFM) for cleaning.\u003c\/li\u003e\n\u003cli\u003eExcessive Contaminant Fuels: May require up to 400 l\/min (14 SCFM).\u003c\/li\u003e\n\u003cli\u003eExtended Probe: Requires 400 l\/min (14 SCFM) for cleaning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e💧 Minimum Cleaning Air Pressure\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eDirect View: 20 mm H2O (1\" W.C.) above the maximum wind box pressure at the \"y\" connection inlet.\u003c\/li\u003e\n\u003cli\u003eExtended Probe: 300 mm H2O (12\" W.C.) above the maximum wind box pressure at the \"y\" connection inlet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e🌡 Maximum Fiber Optic Continuous Operating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e350°C (662°F).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e🔧 Mounting Connection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e1\" NPT male thread.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e🔌 Cable Entry for Electrical Connection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e1\/2\" NPT female thread.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px; font-weight: bold;\"\u003e⚡ Electrical Connections\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eStandard 4 x 0.55 sq.mm (20 AWG) shielded cable.\u003cbr\u003eRecommended maximum length: 300 meters (1000 feet).\u003cbr\u003eFeatures screw type termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45616714580226,"sku":"UR600-IR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR6001R_7.jpg?v=1730791465"},{"product_id":"ur8lm-ge-multilin-ct-vt-ur-8lm-module","title":"UR8LM GE Multilin CT\/VT UR-8LM Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR8LM Module\u003c\/strong\u003e from GE Multilin is designed to provide precise current and voltage measurement for protective relay applications. This module integrates multiple current transformers (CTs) and voltage transformers (VTs) into a single unit, offering reliable performance and enhanced system protection capabilities. It is suitable for a variety of industrial and utility applications, ensuring effective monitoring and control of electrical systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type\u003c\/strong\u003e: CT\/VT \u003cstrong\u003eUR-8LM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase CT Ratings\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Configuration\u003c\/strong\u003e: 3 Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current\u003c\/strong\u003e: 1A \/ 5A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround CT Ratings\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Configuration\u003c\/strong\u003e: 1 Ground CT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current\u003c\/strong\u003e: 1A \/ 5A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: Up to 720V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e: Class 0.2S or better\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: Approximately 0.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 150 mm x 150 mm x 75 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45617055662338,"sku":"UR-8LM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR8LV.jpg?v=1730791399"},{"product_id":"ur-rhv-ge-multilin-urrhv-power-supply-module","title":"UR-RHV GE Multilin URRHV Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eManufacturer: GE Multilin\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eModel: URRHV\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription: \u003c\/strong\u003ePower Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\u003c\/strong\u003e: 100-240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC\u003c\/strong\u003e: 125-250 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVA\u003c\/strong\u003e: 35 VA (AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eW\u003c\/strong\u003e: 35 W (DC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 2.16 lbs (approx. 0.98 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eLength: 6.5 inches\u003c\/li\u003e\n\u003cli\u003eWidth: 6.5 inches\u003c\/li\u003e\n\u003cli\u003eHeight: 1.75 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45617093247234,"sku":"UR-RHV","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR-RHV.jpg?v=1730791753"},{"product_id":"ur-rhh-ge-multilin-urrhh-power-module","title":"UR RHH GE Multilin URRHH Power Module","description":"\u003cdiv style=\"background-color: #e0f0ff; padding: 20px;\"\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold;\"\u003e🔧 \u003cstrong\u003eFeatures\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul style=\"list-style-type: disc; padding-left: 20px;\"\u003e\n\u003cli style=\"padding: 5px 0;\"\u003e\n\u003cstrong\u003eDual Voltage Ranges:\u003c\/strong\u003e\n\u003cul style=\"list-style-type: circle; padding-left: 20px;\"\u003e\n\u003cli\u003eLow Range (LO): 24 to 48 V nominal (DC only)\u003c\/li\u003e\n\u003cli\u003eHigh Range (HI): 125 to 250 V nominal (AC and DC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0;\"\u003e\n\u003cstrong\u003eRedundant Power Option:\u003c\/strong\u003e\n\u003cp\u003eAvailable with or without redundant power options for enhanced reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0;\"\u003e\n\u003cstrong\u003eDry Contact Input Connections:\u003c\/strong\u003e\n\u003cp\u003eSupplies power not only to the relay but also to external dry contact input connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0;\"\u003e\n\u003cstrong\u003eAutomatic Health Assessment:\u003c\/strong\u003e\n\u003cp\u003eThe relay’s self-testing features automatically evaluate the health of the power supply module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0;\"\u003e\n\u003cstrong\u003eFailure Detection:\u003c\/strong\u003e\n\u003cp\u003eMajor and minor tests to assess hardware function and de-energize the module in case of critical failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0;\"\u003e\n\u003cstrong\u003eUser Notification:\u003c\/strong\u003e\n\u003cp\u003eFaceplate LEDs provide immediate status updates:\u003c\/p\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eCONTINUOUS ON: Normal operation\u003c\/li\u003e\n\u003cli\u003eON\/OFF CYCLING: Indicates a problem\u003c\/li\u003e\n\u003cli\u003eOFF: No power or failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold;\"\u003e📊 \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #0066cc; color: white;\"\u003e\n\u003cth style=\"border: 1px solid #003366; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #003366; padding: 10px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px; font-weight: bold;\"\u003eInternal Fuse Rating\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px;\"\u003e4A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px; font-weight: bold;\"\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px;\"\u003e\n\u003cstrong\u003eLow Range:\u003c\/strong\u003e 24 to 48 V DC nominal\u003cbr\u003e\u003cstrong\u003eHigh Range:\u003c\/strong\u003e 125 to 250 V AC\/DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px; font-weight: bold;\"\u003eTesting and Diagnostics\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px;\"\u003eBuilt-in self-testing for integrity checks and failure response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px; font-weight: bold;\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px;\"\u003eProvides visual feedback on power supply status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px; font-weight: bold;\"\u003eInstallation Compatibility\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #003366; padding: 10px;\"\u003eDesigned for seamless installation in the Universal Relays series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45617122148610,"sku":"UR-RHH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR9NH_2_77fa36bd-ca97-4cd6-ac18-5352a342da0d.jpg?v=1730791984"},{"product_id":"ur-8lv-ge-multilin-ur8lv-ct-vt-module","title":"UR-8LV GE Multilin UR8LV CT\/VT Module","description":"\u003cdiv style=\"background-color: #eef3f6; padding: 20px; font-family: Arial, sans-serif;\"\u003e\n\u003c!-- Overview Section --\u003e\n\u003ch3 style=\"border-bottom: 2px solid #cce; color: #333;\"\u003e\u003cstrong\u003eOverview 🌟\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"margin: 10px 0;\"\u003eThe General Electric Multilin \u003cstrong\u003eUR-8LV\u003c\/strong\u003e is part of the Universal Relays series and is designed as a CT\/VT module, offering a standard configuration of 4 current transformers (CT) and 4 voltage transformers (VT). It incorporates advanced diagnostic capabilities that ensure the integrity of analog signals through a sophisticated algorithm. This ensures reliable operation and enhances the module's ability to detect hardware failures, automatically triggering a trip to remove the relay from service until the issue is resolved.\u003c\/p\u003e\n\u003c!-- Technical Specifications Section --\u003e\n\u003ch3 style=\"border-bottom: 2px solid #cce; color: #333;\"\u003e\u003cstrong\u003e📊 Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; background-color: #ffffff; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eUniversal Relay (\u003cstrong\u003eUR-8LV\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCT Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e4 CT inputs for current measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eVT Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e4 VT inputs for voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eRS232 port for serial communication\u003cbr\u003eEthernet capabilities for digital communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eUser Interface\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eKeypad and LCD for local configuration\u003cbr\u003eEnerVista software for advanced configuration and monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e0.87kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45617172840706,"sku":"UR-8LV","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR-RHV_b78f9888-1990-4272-8342-0c5dfb179a44.jpg?v=1730791815"},{"product_id":"ur6dh-ge-multilin-ur-6dh-digital-i-o-module","title":"UR6DH GE Multilin UR-6DH Digital I\/O Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Contacts:\u003c\/strong\u003e 16 Digital Inputs (Form-C only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Type:\u003c\/strong\u003e Form-C (SPDT); no Form-A or fast Form-C support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Compatibility:\u003c\/strong\u003e Compatible with \u003cstrong\u003eEnerVista UR Software\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 6 cm x 20 cm x 17.2 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.86 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24V DC (nominal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 0V to 250V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e Dry contacts (no voltage supplied)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN Rail or screw-mounted installation options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e Modbus RTU (RS-485), Ethernet (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e Max. 50 mA at 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Current:\u003c\/strong\u003e 10 mA per input\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45622437478658,"sku":"UR-6DH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/URSHB2.jpg?v=1730791984"},{"product_id":"ur6th-ge-multilin-ur-6th-digital-i-o-module","title":"UR6TH GE Multilin UR-6TH Digital I\/O Module","description":"\u003ch2 style=\"background: linear-gradient(to right, #a6a6a6, #d9d9d9); color: black; font-weight: bold; padding: 10px; border-radius: 5px;\"\u003e🌐 \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cdiv style=\"background-color: #f7f7f7; padding: 20px; border-radius: 5px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid rgb(51, 51, 51); background: linear-gradient(rgb(230, 230, 230), rgb(249, 249, 249)); height: 862.126px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: rgb(192, 192, 192); height: 19.5938px;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; text-align: left; height: 19.5938px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; text-align: left; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🔢 Digital Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e📏 Number of Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🔌 Input Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003eContact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e⚡ Input Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e24-250V DC or AC (depending on relay configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e⏱️ Input Response Time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e\u0026lt; 10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e🔄 Digital Outputs (Form-A)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🔢 Number of Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e📡 Output Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003eForm-A (non-monitoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e⏰ Activation Speed\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e\u0026lt; 4ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e⚙️ Output Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e30V DC, 1A per output (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🔋 Contact Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e250V AC, 5A (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e⚡ Electrical Power Requirements\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🔋 Operating Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e24V DC, 48V DC (depending on relay model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e⚡ Maximum Power Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e10W (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🔌 Current\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e500mA max per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🏗️ Installation\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🛠️ Mounting Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e19-inch rack, horizontal mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e📏 Form Factor\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e1U height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e🔔 Relay Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003eGE Universal Relays (e.g., T60, UR-6TH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e🌡️ Environmental Conditions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e🌡️ Operating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e-40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e🌡️ Storage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 19.5938px;\"\u003e💧 Humidity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 19.5938px;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e🔄 Relay System Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e🔗 Compatible Relays\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003eCompatible with various GE Universal Relays (e.g., T60, UR-6TH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 58.7812px;\"\u003e🔌 Configurations\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 58.7812px;\"\u003eCan be combined with power supply, CPU, CT\/VT input modules, and transducer input\/output modules.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 58.7812px;\"\u003e⚙️ Module Limitations\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 58.7812px;\"\u003eT60 transformer management relay supports a maximum of three transducer input\/output modules.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); font-weight: bold; height: 39.1875px;\"\u003e🔄 Communication\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(51, 51, 51); height: 39.1875px;\"\u003eA maximum of one inter-relay communications (COMMS).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45622469624066,"sku":"UR-6TH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR9NH_1_857f43f1-28af-4cc4-9ccb-7d4a5b7dbcdd.jpg?v=1730791984"},{"product_id":"ur-8ch-ge-multilin-ct-vt-module-ur8ch","title":"UR-8CH GE Multilin CT\/VT Module UR8CH","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin UR-8CH\u003c\/strong\u003e CT\/VT Module, part of the Universal Relay (UR) Series, is engineered to upgrade or replace existing modules within the system. Equipped with \u003cstrong\u003e3-1A\/5A phase CTs\u003c\/strong\u003e and a \u003cstrong\u003e1\/5A ground CT\u003c\/strong\u003e, this module delivers robust and reliable protection and monitoring capabilities for advanced power systems. Designed for seamless integration, the UR-8CH enhances the performance and versatility of power management applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eUR-8CH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Universal Relay (UR) Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase CTs:\u003c\/strong\u003e 3-1A\/5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround CT:\u003c\/strong\u003e 1\/5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approx. 6” (L) x 7” (W) x 1.5” (H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Compatibility:\u003c\/strong\u003e EnerVista Launchpad for setpoint management and firmware updates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Compatibility:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eFirmware \u003cstrong\u003e3.5x or earlier\u003c\/strong\u003e for older hardware\u003c\/li\u003e\n\u003cli\u003eRequires firmware \u003cstrong\u003e4.0x or newer\u003c\/strong\u003e for newer hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45657120473346,"sku":"UR-8CH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR9NH_1_857f43f1-28af-4cc4-9ccb-7d4a5b7dbcdd.jpg?v=1730791984"},{"product_id":"ur-9eh-ge-multilin-ur9eh-cpu-module","title":"UR-9EH GE Multilin UR9EH CPU Module","description":"\u003ch3\u003e🌐 \u003cstrong\u003eOverview\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric Multilin UR-9EH\u003c\/strong\u003e is a high-performance CPU module engineered for use in the \u003cstrong\u003eUniversal Relay (UR) series\u003c\/strong\u003e. This module provides advanced computing power, enabling precise logic functions, algorithms, and timers essential for relay operation. Designed as a replacement or upgrade for older modules, the UR-9EH ensures reliable and efficient relay performance while maintaining compatibility with the latest features of the UR series. Its \u003cstrong\u003ePlug \u0026amp; Play\u003c\/strong\u003e functionality simplifies installation, allowing for quick integration and minimal programming.\u003c\/p\u003e\n\u003ch3\u003e🌡 \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUR-9EH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultilin Universal Relays (UR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG60, G30, L30, D30, and others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPU Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew (9E to 9S series CPUs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeypad\/Faceplate, EnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eServer Scanning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable; IEC 61850 functionality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug \u0026amp; Play\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurge ground not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal relay-specific ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C (-13°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45657178407170,"sku":"UR-9EH","price":680.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR9NH_2_77fa36bd-ca97-4cd6-ac18-5352a342da0d.jpg?v=1730791984"},{"product_id":"ur8fh-ur-8fh-ge-multilin-ct-vt-module-ur-8fh","title":"UR8FH | UR 8FH GE Multilin CT\/VT Module UR-8FH","description":"\u003ch3 style=\"color: #2a5885;\"\u003eGE Multilin UR-8FH CT\/VT Module – Advanced Motor Protection\u003c\/h3\u003e\n\u003cp\u003eProtect critical motors with the \u003cstrong style=\"color: #d35400;\"\u003eUR-8FH\u003c\/strong\u003e from GE Multilin. This high-accuracy module detects \u003cstrong\u003emechanical jams\u003c\/strong\u003e and \u003cstrong\u003ephase faults\u003c\/strong\u003e with lightning-fast response times under 12ms. Perfect for industrial applications.\u003c\/p\u003e\n\u003ch4 style=\"color: #2a5885;\"\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #27ae60;\"\u003eMechanical Jam Protection\u003c\/strong\u003e: Stops equipment damage with adjustable pickup (1-10× FLA) and 97-98% dropout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #27ae60;\"\u003eDirectional Overcurrent\u003c\/strong\u003e: 90° quadrature voltage sensing with ±2° angle accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #27ae60;\"\u003eUltra-Fast Response\u003c\/strong\u003e: Trips in \u0026lt;12ms for reverse loads, blocks in \u0026lt;8ms for forward faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"color: #2a5885;\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\/Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Multilin UR-8FH (UR8FH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1-10× CT rating (0.5% accuracy up to 2× CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10-600.00s delay (±3% or ±20ms accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.004-3.000 pu (1V steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexLogic™ programmable contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"color: #2a5885;\"\u003eInstallation \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp\u003eWorks with all UR-series relays. Mounts in standard 19\" racks. Requires 24-250V DC\/AC power. Includes DIN rail clips.\u003c\/p\u003e\n\u003ch4 style=\"color: #2a5885;\"\u003eWhat’s Included\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUR-8FH module\u003c\/li\u003e\n\u003cli\u003eInstallation manual\u003c\/li\u003e\n\u003cli\u003eDIN rail mount kit\u003c\/li\u003e\n\u003cli\u003e\u003cstrong style=\"color: #d35400;\"\u003e1-year warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 style=\"color: #2a5885;\"\u003eCertified Protection\u003c\/h4\u003e\n\u003cp\u003eUL 508, CE Mark, IEC 60255 compliant. Used in 15,000+ installations worldwide.\u003c\/p\u003e\n\u003ch4 style=\"color: #2a5885;\"\u003eReal-World Example\u003c\/h4\u003e\n\u003cp\u003eA steel mill reduced motor failures by 72% after installing UR-8FH modules on rolling mill motors (450HP, 4.16kV).\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":46463368298754,"sku":"UR8FH","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/UR9NH_1_857f43f1-28af-4cc4-9ccb-7d4a5b7dbcdd.jpg?v=1730791984"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/collections\/UR9KH-2.jpg?v=1765163645","url":"https:\/\/www.nex-auto.com\/collections\/ge-multilin-ur-series-relays.oembed","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}