{"title":"Honeywell Others","description":null,"products":[{"product_id":"xnxxsg1ss-honeywell-electrochemical-sensor-assembly","title":"XNXXSG1SS Honeywell Electrochemical Sensor Assembly","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSG1SS Electrochemical Sensor Assembly\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003c\/span\u003e XNXXSG1SS\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e Electrochemical (EC) Smart Sensor Assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eTarget Gas:\u003c\/strong\u003e\u003c\/span\u003e Hydrogen (H₂) – Low range\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDetection Range:\u003c\/strong\u003e\u003c\/span\u003e 0 to 1,000 ppm (fixed, non-selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e\u003c\/span\u003e 500 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e\u003c\/span\u003e 30 to 70% of full scale (300–700 ppm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eLower Detectable Limit (LDL):\u003c\/strong\u003e\u003c\/span\u003e 30 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; 60 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; 90 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; ±8 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e\u003c\/span\u003e Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003c\/span\u003e Approx. 4 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; Smart Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePre-configured smart sensor for immediate use with XNX and Series 3000 transmitters.\u003c\/li\u003e\n\u003cli\u003eHot-swappable – replace the \u003cstrong\u003eXNXXSG1SS\u003c\/strong\u003e without removing system power.\u003c\/li\u003e\n\u003cli\u003eStainless steel construction withstands harsh industrial conditions.\u003c\/li\u003e\n\u003cli\u003eContinuous toxic and oxygen monitoring for worker safety.\u003c\/li\u003e\n\u003cli\u003eFixed 0–1000 ppm range with reliable electrochemical response.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Performance Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Full Scale:\u003c\/strong\u003e Not applicable (fixed at 1000 ppm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range:\u003c\/strong\u003e 1000 ppm (Hydrogen, low range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e 30–70% of selected full scale (300–700 ppm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Cal Point:\u003c\/strong\u003e 500 ppm for easy setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse T50:\u003c\/strong\u003e Under 60 seconds – fast initial alarm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse T90:\u003c\/strong\u003e Under 90 seconds – full stabilization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±8 ppm ensures precise readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 30 ppm – reliable at low concentrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -20°C to 55°C for versatile deployment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Stainless steel (SS) for corrosion resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with Honeywell XNX Universal Transmitter.\u003c\/li\u003e\n\u003cli\u003eAlso works with Series 3000 MkII and MkIII gas detector transmitters.\u003c\/li\u003e\n\u003cli\u003eSmart sensor assembly installs directly into the transmitter cradle.\u003c\/li\u003e\n\u003cli\u003eNo special tools required – plug-and-play replacement.\u003c\/li\u003e\n\u003cli\u003eAlways power off the system if hot-swap is not preferred.\u003c\/li\u003e\n\u003cli\u003eRefer to the transmitter manual for step-by-step sensor change.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Honeywell \u003cstrong\u003eXNXXSG1SS\u003c\/strong\u003e Electrochemical Sensor Assembly\u003c\/li\u003e\n\u003cli\u003ePre-installed smart electronics with factory calibration\u003c\/li\u003e\n\u003cli\u003eProtective shipping cap (remove before installation)\u003c\/li\u003e\n\u003cli\u003eInstruction sheet (quick start guide)\u003c\/li\u003e\n\u003cli\u003eNo additional mounting hardware required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShipping weight: approximately 4 kg per unit.\u003c\/li\u003e\n\u003cli\u003eWe ship via \u003cstrong\u003eFedEx, UPS, or DHL\u003c\/strong\u003e – tracking provided.\u003c\/li\u003e\n\u003cli\u003eOrders dispatch within 5 business days.\u003c\/li\u003e\n\u003cli\u003eStock availability: \u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eNew, original, and in stock\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eReturns accepted within 30 days of delivery (conditions apply).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the XNXXSG1SS brand new and original?\u003c\/strong\u003e\u003cbr\u003eYes, we supply 100% new, original Honeywell sensors with full factory specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this sensor with my Series 3000 MkII transmitter?\u003c\/strong\u003e\u003cbr\u003eAbsolutely. The \u003cstrong\u003eXNXXSG1SS\u003c\/strong\u003e is fully compatible with XNX, Series 3000 MkII, and MkIII systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the default calibration gas value?\u003c\/strong\u003e\u003cbr\u003eThe default cal point is 500 ppm, and you can use 30–70% of full scale for adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow long does shipping take?\u003c\/strong\u003e\u003cbr\u003eWe dispatch within 5 business days via FedEx, UPS, or DHL. Delivery times vary by destination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the response time for hydrogen detection?\u003c\/strong\u003e\u003cbr\u003eT50 is under 60 sec, and T90 is under 90 sec – fast and reliable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the sensor if it doesn't fit?\u003c\/strong\u003e\u003cbr\u003eYes, we accept returns within 30 days, provided the sensor is unused and in original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs hot-swapping really safe?\u003c\/strong\u003e\u003cbr\u003eYes, the smart design allows hot-swap, but always follow your site safety procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the lower detectable limit for H₂?\u003c\/strong\u003e\u003cbr\u003eThe LDL is 30 ppm, ensuring sensitivity at low hydrogen concentrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347089502466,"sku":"XNXXSG1SS","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSG1SS-12.jpg?v=1787104017"},{"product_id":"xnxo1ss-honeywell-oxygen-sensor-replacement-cartridge","title":"XNXO1SS Honeywell Oxygen Sensor Replacement Cartridge","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXO1SS Oxygen Sensor Replacement Cartridge\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003c\/span\u003e XNXO1SS\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e Sensor Replacement Cartridge\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eTarget Gas:\u003c\/strong\u003e\u003c\/span\u003e Oxygen (O₂)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003c\/span\u003e 0 to 25% v\/v (volume per volume)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eReplaces:\u003c\/strong\u003e\u003c\/span\u003e S3KO1SS (direct drop-in replacement)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003c\/span\u003e XNX Universal Transmitter, Series 3000 MkII \u0026amp; MkIII\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eSensor Type:\u003c\/strong\u003e\u003c\/span\u003e Electrochemical (EC) smart sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e\u003c\/span\u003e Stainless Steel (SS suffix)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003c\/span\u003e Approx. 4 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; Smart Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePre-configured smart cartridge for immediate oxygen monitoring.\u003c\/li\u003e\n\u003cli\u003eHot-swappable – replace the \u003cstrong\u003eXNXO1SS\u003c\/strong\u003e without powering down the transmitter.\u003c\/li\u003e\n\u003cli\u003eStainless steel construction resists corrosion in harsh industrial settings.\u003c\/li\u003e\n\u003cli\u003eDirectly replaces S3KO1SS with no wiring or configuration changes.\u003c\/li\u003e\n\u003cli\u003eIdeal for continuous oxygen deficiency or enrichment monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDetection Range:\u003c\/strong\u003e\u003c\/span\u003e 0 – 25% v\/v (fixed, non-selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDefault Range:\u003c\/strong\u003e\u003c\/span\u003e 25% v\/v (oxygen in air)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; 60 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; 90 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; ± 0.5% v\/v (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e\u003c\/span\u003e -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e\u003c\/span\u003e 0.5% v\/v\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e\u003c\/span\u003e 30 to 70% of full scale (7.5% – 17.5% v\/v)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDefault Cal Point:\u003c\/strong\u003e\u003c\/span\u003e 12.5% v\/v (typical setting)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Electrochemical, oxygen-specific membrane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the XNXO1SS directly replace the S3KO1SS?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003eXNXO1SS\u003c\/strong\u003e is the direct replacement for the older S3KO1SS oxygen sensor cartridge. It fits the same cradle and uses the same connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this sensor brand new and original Honeywell?\u003c\/strong\u003e\u003cbr\u003eAbsolutely. We supply 100% new, genuine Honeywell \u003cstrong\u003eXNXO1SS\u003c\/strong\u003e cartridges with full factory calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this with my Series 3000 MkII transmitter?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003eXNXO1SS\u003c\/strong\u003e works with XNX, Series 3000 MkII, and MkIII transmitters without any modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the measurement range for oxygen?\u003c\/strong\u003e\u003cbr\u003eThe sensor measures oxygen from 0 to 25% v\/v, which covers both deficiency and enrichment monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow long does shipping take?\u003c\/strong\u003e\u003cbr\u003eWe dispatch within 5 business days via FedEx, UPS, or DHL. Transit time depends on your location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the default calibration point?\u003c\/strong\u003e\u003cbr\u003eThe default cal point is typically 12.5% v\/v, but you can adjust it using 30-70% of full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the cartridge if I order the wrong one?\u003c\/strong\u003e\u003cbr\u003eYes, we accept returns within 30 days, provided the cartridge remains unused and in original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs hot-swapping safe for this oxygen sensor?\u003c\/strong\u003e\u003cbr\u003eYes, the smart design supports hot-swap. However, always follow your facility's safety guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347092287746,"sku":"XNXO1SS","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXO1SS.jpg?v=1787104658"},{"product_id":"xnxxso1ss-honeywell-oxygen-sensor-replacement-assembly","title":"XNXXSO1SS Honeywell Oxygen Sensor Replacement Assembly","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSO1SS Oxygen Sensor Replacement Assembly\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer:\u003c\/strong\u003e\u003c\/span\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003c\/span\u003e XNXXSO1SS\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e Sensor Replacement Assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eTarget Gas:\u003c\/strong\u003e\u003c\/span\u003e Oxygen (O₂)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003c\/span\u003e 0 to 25% v\/v (volume per volume)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDefault Range:\u003c\/strong\u003e\u003c\/span\u003e 25.0 %Vol\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e\u003c\/span\u003e 3.5 %Vol\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDefault Cal Point:\u003c\/strong\u003e\u003c\/span\u003e 20.9 %Vol (fixed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e\u003c\/span\u003e 20.9 %Vol (fixed - air reference)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T20):\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; 10 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e \u0026lt; ± 0.6 %Vol\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e\u003c\/span\u003e -30°C to 55°C (-34°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e\u003c\/span\u003e Stainless Steel (SS suffix)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003c\/span\u003e Approx. 3 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; Smart Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePre-configured smart sensor assembly for immediate oxygen monitoring.\u003c\/li\u003e\n\u003cli\u003eHot-swappable – replace the \u003cstrong\u003eXNXXSO1SS\u003c\/strong\u003e without removing system power.\u003c\/li\u003e\n\u003cli\u003eStainless steel construction withstands harsh and corrosive environments.\u003c\/li\u003e\n\u003cli\u003eExceptionally fast response – T20 under 10 seconds for rapid alarm activation.\u003c\/li\u003e\n\u003cli\u003eFixed calibration at 20.9 %Vol simplifies setup and maintenance.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range from -30°C to 55°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eSelectable Full Scale Range:\u003c\/strong\u003e\u003c\/span\u003e Not applicable (fixed at 25.0 %Vol).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDefault Range:\u003c\/strong\u003e\u003c\/span\u003e 25.0 %Vol (oxygen in air).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eLower Detectable Limit (LDL):\u003c\/strong\u003e\u003c\/span\u003e 3.5 %Vol – reliable low-end detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e\u003c\/span\u003e Fixed at 20.9 %Vol (fresh air equivalent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eDefault Cal Point:\u003c\/strong\u003e\u003c\/span\u003e 20.9 %Vol – matches ambient oxygen level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T20):\u003c\/strong\u003e\u003c\/span\u003e Under 10 seconds – industry-leading speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e\u003c\/span\u003e Under 30 seconds – full stabilization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e ± 0.6 %Vol ensures precise oxygen readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -30°C to 55°C for extreme environment deployment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eSensor Type:\u003c\/strong\u003e\u003c\/span\u003e Electrochemical (EC) smart sensor with oxygen-selective membrane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the XNXXSO1SS a genuine Honeywell product?\u003c\/strong\u003e\u003cbr\u003eYes, we supply 100% new, original Honeywell \u003cstrong\u003eXNXXSO1SS\u003c\/strong\u003e sensor assemblies with full factory calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat transmitters work with this sensor?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eXNXXSO1SS\u003c\/strong\u003e works with Honeywell XNX Universal Transmitter and Series 3000 MkII\/MkIII systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the calibration gas value for this sensor?\u003c\/strong\u003e\u003cbr\u003eThe calibration point is fixed at 20.9 %Vol, which matches normal ambient oxygen concentration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast does this oxygen sensor respond?\u003c\/strong\u003e\u003cbr\u003eExceptional speed – T20 under 10 seconds and T90 under 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the lower detectable limit?\u003c\/strong\u003e\u003cbr\u003eThe LDL is 3.5 %Vol, ensuring reliable detection at low oxygen levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow long does shipping take?\u003c\/strong\u003e\u003cbr\u003eWe dispatch within 5 business days via FedEx, UPS, or DHL. Delivery times vary by region.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the sensor if I ordered the wrong type?\u003c\/strong\u003e\u003cbr\u003eYes, we accept returns within 30 days, provided the assembly remains unused and in original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs hot-swapping safe for this oxygen sensor?\u003c\/strong\u003e\u003cbr\u003eYes, the smart design supports hot-swap. Always follow your facility's safety procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat temperature range does this sensor handle?\u003c\/strong\u003e\u003cbr\u003eIt operates from -30°C to 55°C, suitable for extreme industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347109982466,"sku":"XNXXSO1SS","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSO1SS.jpg?v=1787105326"},{"product_id":"xnxxsc1ss-honeywell-co-cartridge-100-500ppm-sensor","title":"XNXXSC1SS Honeywell CO Cartridge 100-500ppm Sensor","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSC1SS CO Sensor Cartridge – Precision Gas Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNXXSC1SS\u003c\/strong\u003e – a dedicated CO sensor cartridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Ranges:\u003c\/strong\u003e Choose full scale between 100 and 500 ppm. The factory default is 300 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution \u0026amp; Steps:\u003c\/strong\u003e Adjust the range in 100 ppm steps for flexible setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Options:\u003c\/strong\u003e Use calibration gas from 30% to 70% of your selected range. The default calibration point is 100 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed \u0026amp; Accuracy:\u003c\/strong\u003e Response time T50 is under 15 seconds; T90 is under 30 seconds. Accuracy stays within ±2 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Operates from -40°C to +55°C (-40°F to 131°F) without performance loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Detection Limit:\u003c\/strong\u003e The lower detectable limit is 5 ppm, ensuring early warning capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Mounting Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eXNXXSC1SS\u003c\/strong\u003e in a clean, dry location away from direct airflow.\u003c\/li\u003e\n\u003cli\u003eSecure the cartridge using the provided mounting clips or bracket.\u003c\/li\u003e\n\u003cli\u003eConnect the wiring according to the pinout diagram in the user manual.\u003c\/li\u003e\n\u003cli\u003ePower on the system and allow 15 minutes for the sensor to stabilise.\u003c\/li\u003e\n\u003cli\u003ePerform a fresh air calibration before first use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003eXNXXSC1SS\u003c\/strong\u003e CO sensor cartridge (1 unit).\u003c\/li\u003e\n\u003cli\u003eMounting bracket with screws and anchors.\u003c\/li\u003e\n\u003cli\u003eQuick start guide and safety data sheet.\u003c\/li\u003e\n\u003cli\u003eCalibration cap and tubing adaptor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship via FedEx, UPS, or DHL – choose your preferred carrier.\u003c\/li\u003e\n\u003cli\u003eOrders dispatch within 5 business days from our warehouse.\u003c\/li\u003e\n\u003cli\u003eAll cartridges are brand new, original stock with full traceability.\u003c\/li\u003e\n\u003cli\u003eWe support 30-day returns for unopened items in original packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the Honeywell XNXXSC1SS brand new?\u003c\/strong\u003e Yes, we supply only new, original cartridges directly from Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the default full scale range?\u003c\/strong\u003e The default range is 300 ppm, but you can select 100–500 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I change the calibration gas concentration?\u003c\/strong\u003e Yes, use 30% to 70% of your selected full scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast does the sensor respond?\u003c\/strong\u003e T50 is under 15 seconds; T90 is under 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the lowest CO level it can detect?\u003c\/strong\u003e The lower detectable limit is 5 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock available?\u003c\/strong\u003e Yes, we keep this model in stock for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e It works from -40°C to +55°C (-40°F to 131°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I return the product?\u003c\/strong\u003e Contact us within 30 days of receipt for a return authorisation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347113488642,"sku":"XNXXSC1SS","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSC1SS.jpg?v=1787105554"},{"product_id":"xnxxsh1ss-honeywell-cartridge-10-50ppm-sensor","title":"XNXXSH1SS Honeywell Cartridge 10-50ppm Sensor","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSH1SS H₂S Smart Sensor Cartridge – Accurate Low-Level Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNXXSH1SS\u003c\/strong\u003e – a dedicated H₂S (Lo) sensor cartridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Ranges:\u003c\/strong\u003e Choose full scale between 10.0 and 50.0 ppm. The factory default is 15.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution \u0026amp; Steps:\u003c\/strong\u003e Adjust the range in 0.1 ppm steps for fine-tuned setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Options:\u003c\/strong\u003e Use calibration gas from 30% to 70% of your selected range. The default calibration point is 10 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed \u0026amp; Accuracy:\u003c\/strong\u003e Response time T50 is under 20 seconds; T90 is under 30 seconds. Accuracy stays within ±0.3 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Operates from -40°C to +55°C (-40°F to 131°F) without performance loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Detection Limit:\u003c\/strong\u003e The lower detectable limit is 1.0 ppm, ensuring early warning capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the Honeywell XNXXSH1SS brand new?\u003c\/strong\u003e Yes, we supply only new, original cartridges directly from Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the default full scale range?\u003c\/strong\u003e The default range is 15.0 ppm, but you can select 10.0–50.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I change the calibration gas concentration?\u003c\/strong\u003e Yes, use 30% to 70% of your selected full scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast does the sensor respond?\u003c\/strong\u003e T50 is under 20 seconds; T90 is under 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the lowest H₂S level it can detect?\u003c\/strong\u003e The lower detectable limit is 1.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock available?\u003c\/strong\u003e Yes, we keep this model in stock for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e It works from -40°C to +55°C (-40°F to 131°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I return the product?\u003c\/strong\u003e Contact us within 30 days of receipt for a return authorisation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347127185666,"sku":"XNXXSH1SS","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSH1SS.jpg?v=1787105761"},{"product_id":"xnxxsh2ss-honeywell-hydrogen-sulphide-sensor","title":"XNXXSH2SS Honeywell - Hydrogen Sulphide Sensor","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSH2SS H₂S (Hi) Smart Sensor Cartridge – Wide-Range Hydrogen Sulphide Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNXXSH2SS\u003c\/strong\u003e – a dedicated H₂S (Hi) sensor cartridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Ranges:\u003c\/strong\u003e Choose full scale between 50 and 500 ppm. The factory default is 100 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution \u0026amp; Steps:\u003c\/strong\u003e Adjust the range in 10 ppm steps for flexible configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Options:\u003c\/strong\u003e Use calibration gas from 30% to 70% of your selected range. The default calibration point is 50 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed \u0026amp; Accuracy:\u003c\/strong\u003e Response time T50 is under 20 seconds; T90 is under 30 seconds. Accuracy stays within ±5 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Operates from -40°C to +55°C (-40°F to 131°F) without performance loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Detection Limit:\u003c\/strong\u003e The lower detectable limit is 1 ppm, ensuring early warning capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the Honeywell XNXXSH2SS brand new?\u003c\/strong\u003e Yes, we supply only new, original cartridges directly from Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the default full scale range?\u003c\/strong\u003e The default range is 100 ppm, but you can select 50–500 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I change the calibration gas concentration?\u003c\/strong\u003e Yes, use 30% to 70% of your selected full scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast does the sensor respond?\u003c\/strong\u003e T50 is under 20 seconds; T90 is under 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the lowest H₂S level it can detect?\u003c\/strong\u003e The lower detectable limit is 1 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock available?\u003c\/strong\u003e Yes, we keep this model in stock for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e It works from -40°C to +55°C (-40°F to 131°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I return the product?\u003c\/strong\u003e Contact us within 30 days of receipt for a return authorisation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347136655618,"sku":"XNXXSH2SS","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSH2SS.jpg?v=1787106903"},{"product_id":"xnxxsl1ss-chlorine-sensor-0-20ppm-honeywell-xnx-series","title":"XNXXSL1SS Chlorine Sensor 0-20ppm Honeywell XNX Series","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSL1SS Smart Sensor Cartridge for Chlorine Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eSelectable Full Scale Range:\u003c\/strong\u003e\u003c\/span\u003e 5.0 to 20.0 ppm with a default range of 5.0 ppm and 5.0 ppm step increments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e\u003c\/span\u003e 0.6 ppm ensures sensitivity for low-level chlorine exposure risks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e ±0.2 ppm provides reliable readings for critical safety decisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e\u003c\/span\u003e Less than 20 seconds for 50% signal response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e\u003c\/span\u003e Less than 30 seconds for 90% signal response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eSelectable Cal Gas Range:\u003c\/strong\u003e\u003c\/span\u003e 30% to 70% of the selected full-scale range with a default cal point of 2.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -10°C to 55°C (14°F to 131°F) for versatile installation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas does the Honeywell XNXXSL1SS detect?\u003c\/strong\u003e\u003cbr\u003eA: This sensor cartridge detects chlorine (Cl₂) gas for industrial safety monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the selectable measurement range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: You can select any range from 5.0 to 20.0 ppm in 5.0 ppm increments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How accurate is the chlorine reading from this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The sensor provides accuracy of ±0.2 ppm for reliable chlorine detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a new original Honeywell sensor cartridge?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only brand-new, original Honeywell \u003cstrong\u003eXNXXSL1SS\u003c\/strong\u003e cartridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take after placing an order?\u003c\/strong\u003e\u003cbr\u003eA: We process and ship all orders within 5 business days via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The sensor operates from -10°C to 55°C (14°F to 131°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return this product if it doesn’t meet my needs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days of delivery for unused items.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How quickly does the sensor respond to chlorine gas?\u003c\/strong\u003e\u003cbr\u003eA: T50 response time is under 20 seconds, and T90 response time is under 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What calibration gas concentration should I use?\u003c\/strong\u003e\u003cbr\u003eA: Use a calibration gas between 30% and 70% of your selected full-scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this sensor work with the XNX Universal Transmitter?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNXXSL1SS\u003c\/strong\u003e is specifically designed for the Honeywell XNX transmitter series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"%E2%80%9Chttps:\/\/www.nex-auto.com\/%E2%80%9D\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"%E2%80%9Cmailto:sales@nex-auto.com%E2%80%9D\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"%E2%80%9Chttps:\/\/wa.me\/8615392429628%E2%80%9D\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347141767426,"sku":"XNXXSL1SS","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSL1SS.jpg?v=1787107713"},{"product_id":"xnxxsx1ss-honeywell-smart-sensor-clo2-gas-cartridge","title":"XNXXSX1SS Honeywell Smart Sensor ClO2 Gas Cartridge","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSX1SS Smart Sensor Cartridge for Chlorine Dioxide Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eDefault Range:\u003c\/strong\u003e\u003c\/span\u003e 1.00 ppm with a fixed full-scale range for chlorine dioxide detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e\u003c\/span\u003e 0.03 ppm ensures ultra-sensitive monitoring for low-level ClO₂ exposure risks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e ±0.03 ppm provides high-precision readings for critical safety decisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e\u003c\/span\u003e Less than 30 seconds for 50% signal response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e\u003c\/span\u003e Less than 120 seconds for 90% signal response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eSelectable Cal Gas Range:\u003c\/strong\u003e\u003c\/span\u003e 30% to 70% of the selected full-scale range with a default cal point of 0.5 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -20°C to 55°C (-4°F to 131°F) for versatile installation in harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas does the Honeywell XNXXSX1SS detect?\u003c\/strong\u003e\u003cbr\u003eA: This sensor cartridge detects chlorine dioxide (ClO₂) for industrial safety and water treatment monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the measurement range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The sensor has a fixed default range of 1.00 ppm for chlorine dioxide detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How accurate is the chlorine dioxide reading from this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The sensor provides accuracy of ±0.03 ppm for high-precision ClO₂ detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a new original Honeywell sensor cartridge?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only brand-new, original Honeywell \u003cstrong\u003eXNXXSX1SS\u003c\/strong\u003e cartridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take after placing an order?\u003c\/strong\u003e\u003cbr\u003eA: We process and ship all orders within 5 business days via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The sensor operates from -20°C to 55°C (-4°F to 131°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return this product if it doesn't meet my needs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days of delivery for unused items.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How quickly does the sensor respond to chlorine dioxide gas?\u003c\/strong\u003e\u003cbr\u003eA: T50 response time is under 30 seconds, and T90 response time is under 120 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What calibration gas concentration should I use?\u003c\/strong\u003e\u003cbr\u003eA: Use a calibration gas between 30% and 70% of your selected full-scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this sensor work with the XNX Universal Transmitter?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNXXSX1SS\u003c\/strong\u003e is specifically designed for the Honeywell XNX transmitter series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347145011458,"sku":"XNXXSX1SS","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSX1SS.jpg?v=1787107919"},{"product_id":"xnxxsa1ss-ammonia-sensor-0-200ppm-honeywell-xnx-series","title":"XNXXSA1SS Ammonia Sensor 0-200ppm Honeywell XNX Series","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSA1SS Smart Sensor Cartridge for Ammonia Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eSelectable Full Scale Range:\u003c\/strong\u003e\u003c\/span\u003e 50 to 200 ppm with a default range of 200 ppm and 50 ppm step increments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e\u003c\/span\u003e 6 ppm ensures adequate sensitivity for ammonia exposure monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e ±4 ppm provides dependable readings for safety-critical decisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e\u003c\/span\u003e Less than 60 seconds for 50% signal response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e\u003c\/span\u003e Less than 180 seconds for 90% signal response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eSelectable Cal Gas Range:\u003c\/strong\u003e\u003c\/span\u003e 30% to 70% of the selected full-scale range with a default cal point of 100 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41230;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -20°C to 40°C (-4°F to 104°F) for versatile installation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas does the Honeywell XNXXSA1SS detect?\u003c\/strong\u003e\u003cbr\u003eA: This sensor cartridge detects ammonia (NH₃) for agricultural, refrigeration, and industrial safety monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the selectable measurement range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: You can select any range from 50 to 200 ppm in 50 ppm increments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How accurate is the ammonia reading from this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The sensor provides accuracy of ±4 ppm for reliable ammonia detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a new original Honeywell sensor cartridge?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only brand-new, original Honeywell \u003cstrong\u003eXNXXSA1SS\u003c\/strong\u003e cartridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take after placing an order?\u003c\/strong\u003e\u003cbr\u003eA: We process and ship all orders within 5 business days via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The sensor operates from -20°C to 40°C (-4°F to 104°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return this product if it doesn't meet my needs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we accept returns within 30 days of delivery for unused items.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How quickly does the sensor respond to ammonia gas?\u003c\/strong\u003e\u003cbr\u003eA: T50 response time is under 60 seconds, and T90 response time is under 180 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What calibration gas concentration should I use?\u003c\/strong\u003e\u003cbr\u003eA: Use a calibration gas between 30% and 70% of your selected full-scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this sensor work with the XNX Universal Transmitter?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNXXSA1SS\u003c\/strong\u003e is specifically designed for the Honeywell XNX transmitter series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347149238530,"sku":"XNXXSA1SS","price":217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSA1SS.jpg?v=1787108537"},{"product_id":"xnxxss2ss-honeywell-so2-sensor-cartridge-50ppm","title":"XNXXSS2SS Honeywell SO2 Sensor Cartridge 50ppm","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSS2SS Honeywell Smart Sensor Cartridge for SO2 Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Analytics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNXXSS2SS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Detected:\u003c\/strong\u003e Sulfur Dioxide (SO₂) - High Range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Full Scale Range:\u003c\/strong\u003e 20.0 to 50.0 ppm (Default: 50.0 ppm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 1.5 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution Steps:\u003c\/strong\u003e 10.0 ppm increments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Cal Gas Range:\u003c\/strong\u003e 30 to 70% of selected full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e 25 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e Less than 15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e Less than 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.6 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to 55°C (-40°F to 131°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat gas does the XNXXSS2SS detect?\u003c\/strong\u003e \u003cbr\u003eThis cartridge detects sulfur dioxide (SO₂) gas in high ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the default full scale range?\u003c\/strong\u003e \u003cbr\u003eThe default range is 50.0 ppm, but you can select from 20.0 to 50.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this sensor operate in extreme temperatures?\u003c\/strong\u003e \u003cbr\u003eYes, it operates from -40°C to 55°C (-40°F to 131°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the accuracy of this sensor?\u003c\/strong\u003e \u003cbr\u003eThe accuracy is ±0.6 ppm for reliable readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast does the sensor respond?\u003c\/strong\u003e \u003cbr\u003eIt has a T50 response time under 15 seconds and T90 under 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is included in the package?\u003c\/strong\u003e \u003cbr\u003eThe package includes the sensor cartridge, protective cap, and reference sheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat calibration gas should I use?\u003c\/strong\u003e \u003cbr\u003eUse calibration gas at 30-70% of your selected full scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the product new and genuine?\u003c\/strong\u003e \u003cbr\u003eYes, all units are brand new and original from Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you support 30-day returns?\u003c\/strong\u003e \u003cbr\u003eYes, we accept returns within 30 days of purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347151827202,"sku":"XNXXSS2SS","price":217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSS2SS.jpg?v=1787108735"},{"product_id":"xnxxsr1ss-honeywell-hcl-sensor-cartridge-10ppm","title":"XNXXSR1SS Honeywell HCl Sensor Cartridge 10ppm","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSR1SS Honeywell Smart Sensor Cartridge for HCl Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Analytics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNXXSR1SS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Detected:\u003c\/strong\u003e Hydrogen Chloride (HCl)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 to 10 ppm (selectable 10 to 20 ppm, 1 ppm steps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Auto inhibit function for safe maintenance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalogue Output:\u003c\/strong\u003e Selectable source, sink, or isolated output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Factory-calibrated plug-and-play cartridge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP66 rated for harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 kg (11.0 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat gas does the XNXXSR1SS detect?\u003c\/strong\u003e \u003cbr\u003eThis cartridge detects hydrogen chloride (HCl) gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the measurement range?\u003c\/strong\u003e \u003cbr\u003eThe range is 0 to 10 ppm, selectable up to 20 ppm with 1 ppm steps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e \u003cbr\u003eIt operates from -40°C to +65°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the sensor pre-calibrated?\u003c\/strong\u003e \u003cbr\u003eYes, it comes factory-calibrated for plug-and-play installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the ingress protection rating?\u003c\/strong\u003e \u003cbr\u003eIt has an IP66 rating for dust and water resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat analogue output options are available?\u003c\/strong\u003e \u003cbr\u003eYou can select source, sink, or isolated output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is included in the package?\u003c\/strong\u003e \u003cbr\u003eThe package includes the sensor cartridge, protective cap, and reference sheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the product new and genuine?\u003c\/strong\u003e \u003cbr\u003eYes, all units are brand new and original from Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you support 30-day returns?\u003c\/strong\u003e \u003cbr\u003eYes, we accept returns within 30 days of purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48347152613634,"sku":"XNXXSR1SS","price":217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSR1SS.jpg?v=1787108945"},{"product_id":"xnxxsf1ss-honeywell-hf-sensor-cartridge-12-0-ppm","title":"XNXXSF1SS Honeywell HF Sensor Cartridge | 12.0 ppm","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSF1SS Smart Sensor Cartridge for HF Gas Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNXXSF1SS\u003c\/strong\u003e Smart Sensor Cartridge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Target:\u003c\/strong\u003e Hydrogen Fluoride (HF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Scale Range:\u003c\/strong\u003e Fixed at \u003cspan style=\"color: #cc0000;\"\u003e12.0 ppm\u003c\/span\u003e (non-selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e0.4 ppm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e5.0 ppm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e 30% to 70% of full-scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e 120 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e \u0026lt; 240 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e±0.5 ppm\u003c\/span\u003e (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003eXNXXSF1SS\u003c\/strong\u003e compatible with older Honeywell detectors?\u003c\/strong\u003e\u003cbr\u003eYes, it fits all Honeywell bases that accept smart sensor cartridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the typical lifespan of this HF sensor?\u003c\/strong\u003e\u003cbr\u003eExpect 2 to 3 years of active service with proper calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I change the full-scale range on this cartridge?\u003c\/strong\u003e\u003cbr\u003eNo, the range is fixed at 12.0 ppm and is not selectable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does temperature affect the calibration point?\u003c\/strong\u003e\u003cbr\u003eThe sensor automatically compensates within -20°C to 55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas should I use for calibration?\u003c\/strong\u003e\u003cbr\u003eUse HF calibration gas at 30–70% of the 12.0 ppm range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the cartridge pre-calibrated from the factory?\u003c\/strong\u003e\u003cbr\u003eYes, but we recommend a fresh calibration after installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you offer technical support for setup?\u003c\/strong\u003e\u003cbr\u003eWe provide quick-start guides and online resources for assistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I store the cartridge before installation?\u003c\/strong\u003e\u003cbr\u003eKeep it in the original packaging at room temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003c\/strong\u003e\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350402773250,"sku":"XNXXSF1SS","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSF1SS.jpg?v=1787191331"},{"product_id":"xnxxsy1ss-smart-sensor-hcn-gas-honeywell","title":"XNXXSY1SS Smart Sensor HCN Gas | Honeywell","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSY1SS Smart Sensor Cartridge for HCN Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNXXSY1SS\u003c\/strong\u003e Smart Sensor Cartridge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Target:\u003c\/strong\u003e Hydrogen Cyanide (HCN)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Scale Range:\u003c\/strong\u003e Fixed at \u003cspan style=\"color: #cc0000;\"\u003e30.0 ppm\u003c\/span\u003e (non-selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e1.0 ppm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e10.0 ppm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e 30% to 70% of full-scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e \u0026lt; 35 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e \u0026lt; 200 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e±0.4 ppm\u003c\/span\u003e (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003eXNXXSY1SS\u003c\/strong\u003e compatible with older Honeywell detectors?\u003c\/strong\u003e\u003cbr\u003eYes, it fits all Honeywell bases that accept smart sensor cartridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the typical lifespan of this HCN sensor?\u003c\/strong\u003e\u003cbr\u003eExpect 2 to 3 years of active service with proper calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I change the full-scale range on this cartridge?\u003c\/strong\u003e\u003cbr\u003eNo, the range is fixed at 30.0 ppm and is not selectable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does temperature affect the calibration point?\u003c\/strong\u003e\u003cbr\u003eThe sensor automatically compensates within -20°C to 55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas should I use for calibration?\u003c\/strong\u003e\u003cbr\u003eUse HCN calibration gas at 30–70% of the 30.0 ppm range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the cartridge pre-calibrated from the factory?\u003c\/strong\u003e\u003cbr\u003eYes, but we recommend a fresh calibration after installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you offer technical support for setup?\u003c\/strong\u003e\u003cbr\u003eWe provide quick-start guides and online resources for assistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I store the cartridge before installation?\u003c\/strong\u003e\u003cbr\u003eKeep it in the original packaging at room temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003c\/strong\u003e\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350406115586,"sku":"XNXXSY1SS","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSY1SS.jpg?v=1787191958"},{"product_id":"xnxxsp1ss-honeywell-ph3-sensor-cartridge-1-20-ppm","title":"XNXXSP1SS Honeywell PH3 Sensor Cartridge | 1.20 ppm","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSP1SS Smart Sensor Cartridge for PH₃ Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNXXSP1SS\u003c\/strong\u003e Smart Sensor Cartridge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Target:\u003c\/strong\u003e Phosphine (PH₃)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Scale Range:\u003c\/strong\u003e Fixed at \u003cspan style=\"color: #cc0000;\"\u003e1.20 ppm\u003c\/span\u003e (non-selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e0.04 ppm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e0.5 ppm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e 30% to 70% of full-scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e \u0026lt; 15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e \u0026lt; 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e±0.02 ppm\u003c\/span\u003e (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 40°C (-4°F to 104°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the \u003cstrong\u003eXNXXSP1SS\u003c\/strong\u003e compatible with older Honeywell detectors?\u003c\/strong\u003e\u003cbr\u003eYes, it fits all Honeywell bases that accept smart sensor cartridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the typical lifespan of this PH₃ sensor?\u003c\/strong\u003e\u003cbr\u003eExpect 2 to 3 years of active service with proper calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I change the full-scale range on this cartridge?\u003c\/strong\u003e\u003cbr\u003eNo, the range is fixed at 1.20 ppm and is not selectable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does temperature affect the calibration point?\u003c\/strong\u003e\u003cbr\u003eThe sensor automatically compensates within -20°C to 40°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas should I use for calibration?\u003c\/strong\u003e\u003cbr\u003eUse PH₃ calibration gas at 30–70% of the 1.20 ppm range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the cartridge pre-calibrated from the factory?\u003c\/strong\u003e\u003cbr\u003eYes, but we recommend a fresh calibration after installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you offer technical support for setup?\u003c\/strong\u003e\u003cbr\u003eWe provide quick-start guides and online resources for assistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I store the cartridge before installation?\u003c\/strong\u003e\u003cbr\u003eKeep it in the original packaging at room temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003c\/strong\u003e\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350425383170,"sku":"XNXXSP1SS","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSP1SS.jpg?v=1787192130"},{"product_id":"xnxxsh3ss-honeywell-h-s-sensor-cartridge-15ppm","title":"XNXXSH3SS Honeywell H₂S Sensor Cartridge 15ppm","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSH3SS – Honeywell Smart Sensor Cartridge for H₂S (LoLo)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Detected:\u003c\/strong\u003e Hydrogen Sulphide (H₂S) with low-range (LoLo) sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Measurement Range:\u003c\/strong\u003e Fixed at 15.0 ppm – no selectable full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 1.0 ppm ensures sensitivity for trace-level hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e Set to 10 ppm for consistent reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e Under 20 seconds for rapid initial detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e Within 40 seconds for full stabilization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.3 ppm, providing reliable and repeatable readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperating Environment \u0026amp; Dependability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Operates from -40°C to +55°C (-40°F to 131°F).\u003c\/li\u003e\n\u003cli\u003ePerforms consistently in extreme cold or hot industrial settings.\u003c\/li\u003e\n\u003cli\u003eHoneywell engineered the \u003cstrong\u003eXNXXSH3SS\u003c\/strong\u003e to withstand harsh conditions.\u003c\/li\u003e\n\u003cli\u003eNo step increments; direct ppm readout simplifies data interpretation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCalibration \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable calibration gas range: 30% to 70% of the fixed full scale.\u003c\/li\u003e\n\u003cli\u003eDefault cal point at 10 ppm; use certified gas for best results.\u003c\/li\u003e\n\u003cli\u003eInstall the \u003cstrong\u003eXNXXSH3SS\u003c\/strong\u003e into compatible Honeywell smart transmitters.\u003c\/li\u003e\n\u003cli\u003eFollow the cartridge alignment marks for secure, correct placement.\u003c\/li\u003e\n\u003cli\u003ePower up the system and allow 2 minutes for sensor stabilisation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Honeywell \u003cstrong\u003eXNXXSH3SS\u003c\/strong\u003e smart sensor cartridge (H₂S LoLo).\u003c\/li\u003e\n\u003cli\u003eProtective shipping cap for safe storage during transit.\u003c\/li\u003e\n\u003cli\u003eQuick-start calibration reference card.\u003c\/li\u003e\n\u003cli\u003eDesiccant pouch to maintain internal humidity balance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics \u0026amp; Returns\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShipping carriers: FedEx, UPS, and DHL for global delivery.\u003c\/li\u003e\n\u003cli\u003eWe dispatch all orders within 5 business days of purchase.\u003c\/li\u003e\n\u003cli\u003eEach \u003cstrong\u003eXNXXSH3SS\u003c\/strong\u003e unit is brand new, from factory-fresh stock.\u003c\/li\u003e\n\u003cli\u003eReturn policy: 30-day window for hassle-free returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the XNXXSH3SS support a different full-scale range?\u003c\/strong\u003e\u003cbr\u003eNo, the full scale is fixed at 15.0 ppm; no selectable range exists.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum detection level for H₂S?\u003c\/strong\u003e\u003cbr\u003eThe lower detectable limit is 1.0 ppm, ensuring very low-level sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How accurate is the sensor under varying temperature?\u003c\/strong\u003e\u003cbr\u003eAccuracy remains ±0.3 ppm across the full -40°C to 55°C operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use a calibration gas other than 10 ppm?\u003c\/strong\u003e\u003cbr\u003eYes, you may use 30% to 70% of the full scale; default is 10 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the XNXXSH3SS in stock for immediate shipping?\u003c\/strong\u003e\u003cbr\u003eYes, we keep the Honeywell XNXXSH3SS in stock for fast dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you ship internationally?\u003c\/strong\u003e\u003cbr\u003eAbsolutely; we use FedEx, UPS, and DHL for worldwide shipments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What if I need to return the sensor?\u003c\/strong\u003e\u003cbr\u003eWe accept returns within 30 days from delivery for a full refund.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350494294274,"sku":"XNXXSH3SS","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSH3SS.jpg?v=1787192389"},{"product_id":"xnxxss1ss-honeywell-so-sensor-cartridge-5-20ppm","title":"XNXXSS1SS Honeywell SO₂ Sensor Cartridge 5-20ppm","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSS1SS – Honeywell Smart Sensor Cartridge for SO₂ (Low Range)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Detected:\u003c\/strong\u003e Sulphur Dioxide (SO₂) with low-range (Lo) sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Full Scale:\u003c\/strong\u003e 5.0 to 20.0 ppm (adjustable in 5.0 ppm steps).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range:\u003c\/strong\u003e Factory set at 15.0 ppm for immediate use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 0.6 ppm ensures sensitivity for trace-level hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e Set to 5.0 ppm for consistent reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e Under 15 seconds for rapid initial detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e Within 30 seconds for full stabilization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.3 ppm, providing reliable and repeatable readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What full-scale ranges can I select for the XNXXSS1SS?\u003c\/strong\u003e\u003cbr\u003eYou can choose 5.0, 10.0, 15.0, or 20.0 ppm (steps of 5.0 ppm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum detection level for SO₂?\u003c\/strong\u003e\u003cbr\u003eThe lower detectable limit is 0.6 ppm, ensuring very low-level sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How accurate is the sensor under varying temperature?\u003c\/strong\u003e\u003cbr\u003eAccuracy remains ±0.3 ppm across the full -40°C to 55°C operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use a calibration gas other than 5.0 ppm?\u003c\/strong\u003e\u003cbr\u003eYes, you may use 30% to 70% of the selected full scale; default is 5.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the XNXXSS1SS in stock for immediate shipping?\u003c\/strong\u003e\u003cbr\u003eYes, we keep the Honeywell XNXXSS1SS in stock for fast dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you ship internationally?\u003c\/strong\u003e\u003cbr\u003eAbsolutely; we use FedEx, UPS, and DHL for worldwide shipments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What if I need to return the sensor?\u003c\/strong\u003e\u003cbr\u003eWe accept returns within 30 days from delivery for a full refund.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350504091906,"sku":"XNXXSS1SS","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSS1SS.jpg?v=1787192606"},{"product_id":"xnxxsa2ss-smart-sensor-ammonia-high-range-honeywell","title":"XNXXSA2SS Smart Sensor Ammonia High Range Honeywell","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSA2SS – Honeywell Smart Sensor Cartridge for NH₃ (High Range)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Detected:\u003c\/strong\u003e Ammonia (NH₃) with high-range (Hi) sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Full Scale:\u003c\/strong\u003e 200 to 1000 ppm (adjustable in 50 ppm steps).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range:\u003c\/strong\u003e Factory set at 1000 ppm for maximum coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 30 ppm ensures reliable detection at moderate levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e Set to 300 ppm for consistent reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e Under 60 seconds for initial detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e Within 180 seconds for full stabilization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±20 ppm, providing dependable readings in high concentrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperating Environment \u0026amp; Dependability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Operates from -20°C to +40°C (-4°F to 104°F).\u003c\/li\u003e\n\u003cli\u003ePerforms consistently in moderate industrial environments.\u003c\/li\u003e\n\u003cli\u003eHoneywell engineered the \u003cstrong\u003eXNXXSA2SS\u003c\/strong\u003e for stable ammonia detection.\u003c\/li\u003e\n\u003cli\u003eStep size of 50 ppm simplifies range selection for various applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCalibration \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable calibration gas range: 30% to 70% of the chosen full scale.\u003c\/li\u003e\n\u003cli\u003eDefault cal point at 300 ppm; use certified NH₃ gas for best results.\u003c\/li\u003e\n\u003cli\u003eInstall the \u003cstrong\u003eXNXXSA2SS\u003c\/strong\u003e into compatible Honeywell smart transmitters.\u003c\/li\u003e\n\u003cli\u003eFollow the cartridge alignment marks for secure, correct placement.\u003c\/li\u003e\n\u003cli\u003ePower up the system and allow 3 minutes for sensor stabilisation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Honeywell \u003cstrong\u003eXNXXSA2SS\u003c\/strong\u003e smart sensor cartridge (NH₃ Hi).\u003c\/li\u003e\n\u003cli\u003eProtective shipping cap for safe storage during transit.\u003c\/li\u003e\n\u003cli\u003eQuick-start calibration reference card.\u003c\/li\u003e\n\u003cli\u003eDesiccant pouch to maintain internal humidity balance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics \u0026amp; Returns\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShipping carriers: FedEx, UPS, and DHL for global delivery.\u003c\/li\u003e\n\u003cli\u003eWe dispatch all orders within 5 business days of purchase.\u003c\/li\u003e\n\u003cli\u003eEach \u003cstrong\u003eXNXXSA2SS\u003c\/strong\u003e unit is brand new, from factory-fresh stock.\u003c\/li\u003e\n\u003cli\u003eReturn policy: 30-day window for hassle-free returns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What full-scale ranges can I select for the XNXXSA2SS?\u003c\/strong\u003e\u003cbr\u003eYou can choose from 200 to 1000 ppm in 50 ppm increments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum detection level for NH₃?\u003c\/strong\u003e\u003cbr\u003eThe lower detectable limit is 30 ppm for this high-range sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How accurate is the sensor in varying conditions?\u003c\/strong\u003e\u003cbr\u003eAccuracy is ±20 ppm across the -20°C to 40°C operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use a calibration gas other than 300 ppm?\u003c\/strong\u003e\u003cbr\u003eYes, you may use 30% to 70% of the selected full scale; default is 300 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the XNXXSA2SS in stock for immediate shipping?\u003c\/strong\u003e\u003cbr\u003eYes, we keep the Honeywell XNXXSA2SS in stock for fast dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you ship internationally?\u003c\/strong\u003e\u003cbr\u003eAbsolutely; we use FedEx, UPS, and DHL for worldwide shipments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What if I need to return the sensor?\u003c\/strong\u003e\u003cbr\u003eWe accept returns within 30 days from delivery for a full refund.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350530371842,"sku":"XNXXSA2SS","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSA2SS.jpg?v=1787192835"},{"product_id":"xnxxsl2ss-honeywell-cl-transmitter-modbus-rtu","title":"XNXXSL2SS Honeywell Cl₂ Transmitter Modbus RTU","description":"\u003ch2\u003e\u003cstrong\u003eXNXXSL2SS – Honeywell XNX Universal Transmitter with Cl₂ Sensor \u0026amp; Modbus Output\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eGas Detection Specifications (Chlorine – Low Range)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Detected:\u003c\/strong\u003e Chlorine (Cl₂) with low-range (Lo) sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range:\u003c\/strong\u003e Fixed at 5.00 ppm for precise low-level monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 0.15 ppm ensures exceptional trace-level sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e Set to 2.0 ppm for consistent reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e Under 20 seconds for rapid initial detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e Within 60 seconds for full stabilization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.2 ppm, providing highly reliable and repeatable readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Operates from -10°C to 55°C (14°F to 131°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModbus Output Module Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Isolated RS485 for multi-drop Modbus network integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Layer:\u003c\/strong\u003e RS485 with baud rates from 1200 to 19.2K.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Nodes:\u003c\/strong\u003e Supports up to 254 XNX compatible transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Modbus RTU for seamless industrial communication.\u003c\/li\u003e\n\u003cli\u003eFunctions supported align with Foundation Fieldbus module options.\u003c\/li\u003e\n\u003cli\u003eMutually exclusive with relay and Foundation Fieldbus modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use the XNXXSL2SS with other network protocols?\u003c\/strong\u003e\u003cbr\u003eNo, the Modbus module is exclusive; it cannot work with relays or Foundation Fieldbus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the minimum detection level for chlorine?\u003c\/strong\u003e\u003cbr\u003eThe lower detectable limit is 0.15 ppm for this low-range Cl₂ sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How accurate is the chlorine sensor?\u003c\/strong\u003e\u003cbr\u003eAccuracy is ±0.2 ppm across the -10°C to 55°C operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What calibration gas should I use?\u003c\/strong\u003e\u003cbr\u003eYou may use 30% to 70% of full scale; default calibration point is 2.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many XNX transmitters can connect on one network?\u003c\/strong\u003e\u003cbr\u003eThe Modbus network supports up to 254 XNX compatible transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the XNXXSL2SS in stock for immediate shipping?\u003c\/strong\u003e\u003cbr\u003eYes, we keep the Honeywell XNXXSL2SS in stock for fast dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you ship internationally?\u003c\/strong\u003e\u003cbr\u003eAbsolutely; we use FedEx, UPS, and DHL for worldwide shipments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What if I need to return the transmitter?\u003c\/strong\u003e\u003cbr\u003eWe accept returns within 30 days from delivery for a full refund.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350532141314,"sku":"XNXXSL2SS","price":249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSL2SS.jpg?v=1787193549"},{"product_id":"xnxxsm1ss-honeywell-smart-sensor-no-modbus-rtu","title":"XNXXSM1SS Honeywell Smart Sensor NO Modbus RTU","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSM1SS Smart Sensor for Nitric Oxide (NO)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e XNXXSM1SS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Nitric Oxide (NO) \/ Nitrogen Monoxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Full Scale Range:\u003c\/strong\u003e 100 ppm (selectable range not applicable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 3 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±2 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e \u0026lt; 15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e \u0026lt; 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e 30% to 70% of selected full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e 50 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Layer:\u003c\/strong\u003e Isolated RS485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate:\u003c\/strong\u003e 1200 to 19.2K baud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Nodes:\u003c\/strong\u003e 254 XNX compatible transmitters only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Modbus RTU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e RS485+, RS485-, Drain\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the Honeywell XNXXSM1SS a new and original product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only brand new, original modules. We do not sell used or refurbished units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum number of nodes on the Modbus network?\u003c\/strong\u003e\u003cbr\u003eA: The network supports up to 254 XNX compatible transmitters. The \u003cstrong\u003eXNXXSM1SS\u003c\/strong\u003e acts as one node on this RS485 bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I install this module in the field by myself?\u003c\/strong\u003e\u003cbr\u003eA: Only a qualified service engineer should perform field installation to avoid damage or improper wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take and which carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch orders within 5 days via FedEx, UPS, or DHL. Delivery times vary by destination but typically range from 2 to 5 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this module work with Foundation Fieldbus or relays simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: No, the Modbus output is mutually exclusive with relays and Foundation Fieldbus options. You must choose one communication method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the default calibration point and range?\u003c\/strong\u003e\u003cbr\u003eA: The default calibration point is 50 ppm. You can select a calibration gas between 30% and 70% of the full scale range (100 ppm default).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you accept returns if the product does not meet our needs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support returns within 30 days of delivery. The module must be in new, unused condition with all original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eHoneywell XNXXSM1SS\u003c\/strong\u003e operates reliably from -20°C (-4°F) to 55°C (131°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350547345666,"sku":"XNXXSM1SS","price":249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSM1SS.jpg?v=1787194031"},{"product_id":"xnxxsn1ss-honeywell-smart-sensor-nitrogen-dioxide","title":"XNXXSN1SS Honeywell Smart Sensor Nitrogen Dioxide","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSN1SS Smart Sensor for Nitrogen Dioxide (NO₂)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e XNXXSN1SS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Nitrogen Dioxide (NO₂)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Full Scale Range:\u003c\/strong\u003e 5.0 to 50.0 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range:\u003c\/strong\u003e 10.0 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 1.5 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep Increment:\u003c\/strong\u003e 5.0 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.2 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e \u0026lt; 15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e \u0026lt; 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e 30% to 70% of selected full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e 5 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Layer:\u003c\/strong\u003e Isolated RS485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate:\u003c\/strong\u003e 1200 to 19.2K baud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Nodes:\u003c\/strong\u003e 254 XNX compatible transmitters only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Modbus RTU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e RS485+, RS485-, Drain\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the Honeywell XNXXSN1SS a new and original product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only brand new, original modules. We do not sell used or refurbished units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the default measurement range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The default range is 10.0 ppm. You can select any range between 5.0 and 50.0 ppm in 5.0 ppm steps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the accuracy of the XNXXSN1SS?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eHoneywell XNXXSN1SS\u003c\/strong\u003e delivers an accuracy of ±0.2 ppm, ensuring precise NO₂ detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I install this module in the field by myself?\u003c\/strong\u003e\u003cbr\u003eA: Only a qualified service engineer should handle field installation to prevent wiring errors or damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take and which carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch orders within 5 days via FedEx, UPS, or DHL. Delivery typically takes 2 to 5 business days depending on your location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this module work with Foundation Fieldbus or relays at the same time?\u003c\/strong\u003e\u003cbr\u003eA: No, the Modbus output is mutually exclusive with relays and Foundation Fieldbus options. You must select one communication method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the default calibration point?\u003c\/strong\u003e\u003cbr\u003eA: The default calibration point is 5 ppm. You can select a calibration gas between 30% and 70% of your chosen full scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you accept returns if the product does not meet our requirements?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support returns within 30 days of delivery. The module must remain in new, unused condition with all original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eHoneywell XNXXSN1SS\u003c\/strong\u003e operates reliably from -20°C (-4°F) to 55°C (131°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350548164866,"sku":"XNXXSN1SS","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSN1SS.jpg?v=1787194211"},{"product_id":"xnxxsg2ss-honeywell-xnx-ec-sensor","title":"XNXXSG2SS Honeywell - XNX EC Sensor","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSG2SS Smart Sensor for Hydrogen (H₂)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e XNXXSG2SS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Hydrogen (H₂)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Full Scale Range:\u003c\/strong\u003e 10,000 ppm (selectable range not applicable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 300 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±150 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e \u0026lt; 15 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e \u0026lt; 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Gas Range:\u003c\/strong\u003e 30% to 70% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e 5000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Layer:\u003c\/strong\u003e Isolated RS485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate:\u003c\/strong\u003e 1200 to 19.2K baud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Nodes:\u003c\/strong\u003e 254 XNX compatible transmitters only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol:\u003c\/strong\u003e Modbus RTU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e RS485+, RS485-, Drain\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the Honeywell XNXXSG2SS a new and original product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only brand new, original modules. We do not sell used or refurbished units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the default measurement range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: The default range is 10,000 ppm for Hydrogen detection. This range is fixed and not selectable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the accuracy of the XNXXSG2SS?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eHoneywell XNXXSG2SS\u003c\/strong\u003e delivers an accuracy of ±150 ppm, ensuring reliable H₂ detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I install this module in the field by myself?\u003c\/strong\u003e\u003cbr\u003eA: Only a qualified service engineer should handle field installation to prevent wiring errors or damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take and which carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch orders within 5 days via FedEx, UPS, or DHL. Delivery typically takes 2 to 5 business days depending on your location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this module work with Foundation Fieldbus or relays at the same time?\u003c\/strong\u003e\u003cbr\u003eA: No, the Modbus output is mutually exclusive with relays and Foundation Fieldbus options. You must select one communication method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the default calibration point?\u003c\/strong\u003e\u003cbr\u003eA: The default calibration point is 5000 ppm. You can select a calibration gas between 30% and 70% of the full scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you accept returns if the product does not meet our requirements?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support returns within 30 days of delivery. The module must remain in new, unused condition with all original packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eHoneywell XNXXSG2SS\u003c\/strong\u003e operates reliably from -20°C (-4°F) to 55°C (131°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48350551179522,"sku":"XNXXSG2SS","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSG2SS.jpg?v=1787195231"},{"product_id":"xnxxsu1ss-honeywell-smart-sensor-modbus-rtu-output-module","title":"XNXXSU1SS Honeywell Smart Sensor Modbus RTU Output Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSU1SS Smart Sensor - Modbus RTU Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003eXNXXSU1SS\u003c\/strong\u003e (Smart Sensor Module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Protocol\u003c\/strong\u003e: Modbus RTU (supports Foundation Fieldbus module functions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Ports\u003c\/strong\u003e: RS485+, RS485-, Drain (shield)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type\u003c\/strong\u003e: Fluorine (F₂)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range\u003c\/strong\u003e: 4.00 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit\u003c\/strong\u003e: 0.36 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Cal Point\u003c\/strong\u003e: 2.00 ppm (adjustable 30%~70% of full scale)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time\u003c\/strong\u003e: T50 \u0026lt; 5 sec, T90 \u0026lt; 30 sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.03 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Nodes\u003c\/strong\u003e: 254 XNX-compatible transmitters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is XNXXSU1SS compatible with other brands' transmitters?\u003c\/strong\u003e\u003cbr\u003eA: No, it supports only Honeywell XNX series transmitters, with a maximum of 254 nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the lower detection limit for Fluorine (F₂)?\u003c\/strong\u003e\u003cbr\u003eA: The lower detectable limit is 0.36 ppm, with a default range of 4.00 ppm for low-concentration monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I set the calibration gas concentration?\u003c\/strong\u003e\u003cbr\u003eA: You can select 30% to 70% of the full scale range; the default calibration point is 2.00 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I install this module in the field?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but only a qualified service engineer should perform field installation to ensure safety and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the Modbus baud rate adjustable?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports baud rates from 1200 to 19.2K, configurable to your network requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product brand new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply brand new original Honeywell \u003cstrong\u003eXNXXSU1SS\u003c\/strong\u003e modules with ample stock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359345127682,"sku":"XNXXSU1SS","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSU1SS.jpg?v=1787278937"},{"product_id":"xnxxsz1ss-honeywell-ozone-sensor-output-module","title":"XNXXSZ1SS Honeywell Ozone Sensor Output Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSZ1SS Smart Sensor - Ozone (O₃) Modbus RTU Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCore Advantage\u003c\/strong\u003e: Isolated RS485 physical layer supports baud rates from 1200 to 19.2K and connects up to 254 XNX-compatible transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Performance\u003c\/strong\u003e: Ozone (O₃) default range is 0.400 ppm with a lower detectable limit of 0.032 ppm and T90 response under 60 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Flexibility\u003c\/strong\u003e: Cal gas range adjusts from 30% to 70% of full scale, with a default calibration point of 0.200 ppm for easy field setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Durability\u003c\/strong\u003e: Wide operating temperature from -20°C to 55°C ensures stable output in harsh industrial conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Honeywell Analytics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003eXNXXSZ1SS\u003c\/strong\u003e (Smart Ozone Sensor Module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Protocol\u003c\/strong\u003e: Modbus RTU (supports Foundation Fieldbus module functions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Ports\u003c\/strong\u003e: RS485+, RS485-, Drain (shield)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type\u003c\/strong\u003e: O₃ (Ozone)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range\u003c\/strong\u003e: 0.400 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit\u003c\/strong\u003e: 0.032 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Cal Point\u003c\/strong\u003e: 0.200 ppm (adjustable 30%~70% of full scale)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time\u003c\/strong\u003e: T50 \u0026lt; 15 sec, T90 \u0026lt; 60 sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.003 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Nodes\u003c\/strong\u003e: 254 XNX-compatible transmitters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is XNXXSZ1SS compatible with other brands' transmitters?\u003c\/strong\u003e\u003cbr\u003eA: No, it supports only Honeywell XNX series transmitters, with a maximum of 254 nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the lower detection limit for Ozone (O₃)?\u003c\/strong\u003e\u003cbr\u003eA: The lower detectable limit is 0.032 ppm, with a default range of 0.400 ppm for low-concentration monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I set the calibration gas concentration?\u003c\/strong\u003e\u003cbr\u003eA: You can select 30% to 70% of the full scale range; the default calibration point is 0.200 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I install this module in the field?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but only a qualified service engineer should perform field installation to ensure safety and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the Modbus baud rate adjustable?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports baud rates from 1200 to 19.2K, configurable to your network requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product brand new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply brand new original Honeywell \u003cstrong\u003eXNXXSZ1SS\u003c\/strong\u003e modules with ample stock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359347257602,"sku":"XNXXSZ1SS","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSZ1SS.jpg?v=1787279482"},{"product_id":"xnxxse1ss-honeywell-ethylene-oxide-gas-sensor","title":"XNXXSE1SS Honeywell Ethylene Oxide Gas Sensor","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSE1SS Smart Sensor - Ethylene Oxide (ETO) Modbus RTU Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cstrong\u003eXNXXSE1SS\u003c\/strong\u003e (Smart ETO Sensor Module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Protocol\u003c\/strong\u003e: Modbus RTU (supports Foundation Fieldbus module functions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Ports\u003c\/strong\u003e: RS485+, RS485-, Drain (shield)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type\u003c\/strong\u003e: ETO (Ethylene Oxide)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Full Scale Range\u003c\/strong\u003e: 20.0 to 50.0 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range\u003c\/strong\u003e: 25.0 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit\u003c\/strong\u003e: 1.0 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteps\u003c\/strong\u003e: 5.0 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Cal Point\u003c\/strong\u003e: 10.0 ppm (adjustable 30%~70% of full scale)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time\u003c\/strong\u003e: T50 \u0026lt; 40 sec, T90 \u0026lt; 125 sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.3 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Nodes\u003c\/strong\u003e: 254 XNX-compatible transmitters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is XNXXSE1SS compatible with other brands' transmitters?\u003c\/strong\u003e\u003cbr\u003eA: No, it supports only Honeywell XNX series transmitters, with a maximum of 254 nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the detection range for Ethylene Oxide (ETO)?\u003c\/strong\u003e\u003cbr\u003eA: The selectable full scale range is 20.0 to 50.0 ppm, with a default range of 25.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I set the calibration gas concentration?\u003c\/strong\u003e\u003cbr\u003eA: You can select 30% to 70% of the full scale range; the default calibration point is 10.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I install this module in the field?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but only a qualified service engineer should perform field installation to ensure safety and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the Modbus baud rate adjustable?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports baud rates from 1200 to 19.2K, configurable to your network requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product brand new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply brand new original Honeywell \u003cstrong\u003eXNXXSE1SS\u003c\/strong\u003e modules with ample stock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359362265346,"sku":"XNXXSE1SS","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXXSE1SS.jpg?v=1787279662"},{"product_id":"xnx-amse-nhnnn-honeywell-xnx-transmitter-modbus","title":"XNX-AMSE-NHNNN Honeywell XNX Transmitter Modbus","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-AMSE-NHNNN Universal Transmitter with Smart Sensor Cartridges\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct No.\u003c\/strong\u003e: \u003cstrong\u003eXNX-AMSE-NHNNN\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: XNX Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: XNX Universal Transmitter With Cartridges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: A - ATEX\/IEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntry Type\u003c\/strong\u003e: M - M25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: S - 316 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality\u003c\/strong\u003e: E - Interface for Electrochemical Cartridges (Includes IS Barrier and Adaptor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption\u003c\/strong\u003e: N - No Option installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal HART\u003c\/strong\u003e: H - Local HART\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor and Range\u003c\/strong\u003e: NNN - None (cartridges ordered separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Protocol\u003c\/strong\u003e: Modbus RTU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Ports\u003c\/strong\u003e: RS485+, RS485-, Drain (shield)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Layer\u003c\/strong\u003e: Isolated RS485, 1200 to 19.2K baud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Nodes\u003c\/strong\u003e: 254 XNX-compatible transmitters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to 55°C (-4°F to 131°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What approvals does XNX-AMSE-NHNNN carry?\u003c\/strong\u003e\u003cbr\u003eA: This model has ATEX\/IEC approval (code A), suitable for hazardous area installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What sensor cartridges work with this transmitter?\u003c\/strong\u003e\u003cbr\u003eA: It uses electrochemical cartridges for toxic and oxygen gases, ordered separately (sensor NNN indicates none included).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the Modbus output standard on this model?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the Modbus output module provides isolated RS485 for multi-drop network connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the enclosure material?\u003c\/strong\u003e\u003cbr\u003eA: The housing is 316 stainless steel (code S) for maximum corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this transmitter support HART communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, local HART (code H) enables configuration and diagnostics at the device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I install the Modbus module in the field?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but only a qualified service engineer should perform field installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the product brand new and original?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply brand new original Honeywell \u003cstrong\u003eXNX-AMSE-NHNNN\u003c\/strong\u003e transmitters with ample stock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359367770370,"sku":"XNX-AMSE-NHNNN","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMSE-NHNNN.jpg?v=1787279851"},{"product_id":"xnx-amai-rnnnn-honeywell-universal-transmitter-atex-iec","title":"XNX-AMAI-RNNNN | Honeywell Universal Transmitter ATEX IEC","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-AMAI-RNNNN Universal Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell – a global leader in safety and detection technologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Model:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMAI-RNNNN\u003c\/strong\u003e (Universal Transmitter with relay and IR interface).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e ATEX\/IEC certified (A = ATEX\/IEC) for hazardous area use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Aluminium housing (A) with M25 entry (M) – durable and corrosion-resistant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Infrared interface (I) for Searchline Excel, Searchpoint Optima, and generic 4-20 mA sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Option:\u003c\/strong\u003e Integrated relay (R) for alarm or control outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal HART:\u003c\/strong\u003e Not installed (N) – keep the configuration simple.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor \u0026amp; Range:\u003c\/strong\u003e None supplied (NNN) – you can add your own compatible sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40ºC to +65ºC (-40ºF to +149ºF) – suitable for extreme climates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0–99% RH (non-condensing) for reliable performance in wet areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 90–110 kPa – works at normal atmospheric conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -40ºC to 75ºC (-40ºF to 167ºF) with 0–99% non-condensing humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16 cm x 19.7 cm x 11.4 cm (6.1\" x 7.8\" x 4.5\") – compact footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 kg – sturdy but manageable for wall or pipe mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Surface mount via integral lugs. Optional pipe kit for Ø100–150 mm (4–6 inch) pipes. Optional ceiling bracket available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Package Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEach unit includes the transmitter, mounting lugs, and basic hardware for surface installation.\u003c\/li\u003e\n\u003cli\u003eWe provide the \u003cstrong\u003eXNX-AMAI-RNNNN\u003c\/strong\u003e with a relay option already integrated.\u003c\/li\u003e\n\u003cli\u003ePackage does not include sensor or pipe mounting kit – order separately if needed.\u003c\/li\u003e\n\u003cli\u003eYou will receive a quick-start guide and terminal connection diagram in the box.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and factory-tested before shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Returns\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe stock this model in our warehouse – ready for immediate dispatch.\u003c\/li\u003e\n\u003cli\u003eWe ship within 5 business days after order confirmation.\u003c\/li\u003e\n\u003cli\u003eWe use FedEx, UPS, or DHL for fast and traceable delivery worldwide.\u003c\/li\u003e\n\u003cli\u003eWe accept returns within 30 days of receipt – please contact us for a return authorization.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new – no used or refurbished products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this transmitter with a non-Honeywell sensor?\u003c\/strong\u003e\u003cbr\u003eYes, the generic 4-20 mA input supports many third-party sensors with a 4-20 mA output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the \u003cstrong\u003eXNX-AMAI-RNNNN\u003c\/strong\u003e include a display or local interface?\u003c\/strong\u003e\u003cbr\u003eNo display is included, but the infrared interface allows configuration with a handheld IR programmer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable length for the 4-20 mA loop?\u003c\/strong\u003e\u003cbr\u003eWe recommend up to 300 meters (1000 ft) with proper shielding and power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the relay output configurable?\u003c\/strong\u003e\u003cbr\u003eYes, you can set the relay for alarm, fault, or control functions using the IR interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you offer technical support for installation?\u003c\/strong\u003e\u003cbr\u003eYes, our team provides remote assistance and documentation to help you set up the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I mount this transmitter outdoors?\u003c\/strong\u003e\u003cbr\u003eYes, the aluminium enclosure and wide temperature range make it suitable for outdoor use with proper weather protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003c\/em\u003e\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359385366786,"sku":"XNX-AMAI-RNNNN","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMAI-RNNNN.jpg?v=1787280070"},{"product_id":"xnx-amav-nncb1-honeywell-universal-transmitter","title":"XNX-AMAV-NNCB1 | Honeywell Universal Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-AMAV-NNCB1 Universal Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell – a trusted name in safety and gas detection technology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Model:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMAV-NNCB1\u003c\/strong\u003e (Universal Transmitter with catalytic bead sensor).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e ATEX\/IEC certified (A) for hazardous area installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Aluminium housing (A) with M25 entry (M) – corrosion-resistant and durable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Infrared interface (V) for Searchline Excel, Searchpoint Optima, and generic 4-20 mA sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptions:\u003c\/strong\u003e No relay or HART installed (N, N) – keep the configuration straightforward.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor \u0026amp; Range:\u003c\/strong\u003e CB1 catalytic bead sensor included – detects combustible gases accurately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 kg – robust but manageable for wall or pipe mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40ºC to +65ºC (-40ºF to +149ºF) – suitable for extreme climates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0–99% RH (non-condensing) for reliable operation in wet areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 90–110 kPa – works under normal atmospheric conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -40ºC to 75ºC (-40ºF to 167ºF) with 0–99% non-condensing humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16 cm x 19.7 cm x 11.4 cm (6.1\" x 7.8\" x 4.5\") – compact footprint for tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Surface mount via integral lugs. Optional pipe kit for Ø100–150 mm (4–6 inch) pipes. Optional ceiling bracket available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat gas does the CB1 catalytic bead sensor detect?\u003c\/strong\u003e\u003cbr\u003eThe CB1 sensor detects combustible gases such as methane, propane, and hydrogen in LEL ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I replace the sensor with a different type?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003eXNX-AMAV-NNCB1\u003c\/strong\u003e supports other Honeywell sensors via the generic 4-20 mA input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this transmitter have a display or local readout?\u003c\/strong\u003e\u003cbr\u003eNo display is included – you need an external IR programmer for configuration and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the response time of the catalytic bead sensor?\u003c\/strong\u003e\u003cbr\u003eTypical T90 response is less than 15 seconds for most combustible gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the aluminium housing suitable for offshore environments?\u003c\/strong\u003e\u003cbr\u003eYes, the corrosion-resistant aluminium enclosure and IP rating make it suitable for offshore and onshore use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you provide technical support for configuration?\u003c\/strong\u003e\u003cbr\u003eYes, our team offers remote assistance and detailed documentation to help you set up the device.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003c\/em\u003e\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359479345410,"sku":"XNX-AMAV-NNCB1","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMAV-NNCB1.jpg?v=1787281406"},{"product_id":"xnx-amav-nnic1-honeywell-xnx-transmitter","title":"XNX-AMAV-NNIC1 Honeywell - XNX Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eXNX-AMAV-NNIC1 Honeywell XNX Universal Transmitter Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMAV-NNIC1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e XNX Universal Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX and IEC certified for explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntry Type:\u003c\/strong\u003e M25 cable entry for secure wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Painted aluminium (LM25) with marine-grade coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Millivolt (mV) interface for MPD and Sensepoint sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Infrared (IR) for carbon dioxide detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e0 to 5% Vol CO2\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20mA with HART protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 20 to 90% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP66 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.01% Vol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±2% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e T90 less than 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e Meets EN 61000-6-3 and EN 61000-6-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas does this \u003cstrong\u003eXNX-AMAV-NNIC1\u003c\/strong\u003e measure?\u003c\/strong\u003e\u003cbr\u003eA: This \u003cstrong\u003eHoneywell XNX\u003c\/strong\u003e transmitter measures carbon dioxide (CO2) from 0 to 5% Vol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this unit suitable for outdoor use?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the IP66\/NEMA 4X aluminium enclosure provides excellent weather resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this transmitter support the HART communication protocol?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNX-AMAV-NNIC1\u003c\/strong\u003e supports HART for remote configuration and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the typical response time for the CO2 sensor?\u003c\/strong\u003e\u003cbr\u003eA: The IR sensor achieves a T90 response time of less than 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this unit with Sensepoint probes?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the millivolt interface supports MPD, Sensepoint, Model 705 HT, and PPM sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I calibrate the zero point?\u003c\/strong\u003e\u003cbr\u003eA: Use the magnetic switch on the display or the HART communicator to start zero calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What approvals does this model carry?\u003c\/strong\u003e\u003cbr\u003eA: It carries ATEX and IECEx approvals for use in Zone 1 and Zone 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a new unit or refurbished?\u003c\/strong\u003e\u003cbr\u003eA: We supply only brand new, original \u003cstrong\u003eHoneywell XNX\u003c\/strong\u003e transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359481278722,"sku":"XNX-AMAV-NNIC1","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMAV-NNIC1.jpg?v=1787281601"},{"product_id":"xnx-amav-nniv1-universal-transmitter-honeywell-lel-sensor","title":"XNX-AMAV-NNIV1 Universal Transmitter | Honeywell LEL Sensor","description":"\u003ch2\u003e\u003cstrong\u003eXNX-AMAV-NNIV1 Honeywell XNX Universal Transmitter Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMAV-NNIV1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e XNX Universal Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX and IECEx certified for explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntry Type:\u003c\/strong\u003e M25 cable entry for secure wiring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Painted aluminium (LM25) with marine-grade coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Millivolt (mV) interface for MPD and Sensepoint sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Infrared (IR) for methane (CH4) detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e0 to 100% LEL (or 0 to 5% Vol.) Methane\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20mA with HART protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 20 to 90% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP66 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1% LEL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±3% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e T90 less than 20 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e Meets EN 61000-6-3 and EN 61000-6-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas does this \u003cstrong\u003eXNX-AMAV-NNIV1\u003c\/strong\u003e detect?\u003c\/strong\u003e\u003cbr\u003eA: This \u003cstrong\u003eHoneywell XNX\u003c\/strong\u003e transmitter detects methane (CH4) from 0 to 100% LEL or 0 to 5% Vol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this unit suitable for outdoor use?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the IP66\/NEMA 4X aluminium enclosure provides excellent weather resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this transmitter support HART communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNX-AMAV-NNIV1\u003c\/strong\u003e supports HART for remote configuration and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the typical response time for methane?\u003c\/strong\u003e\u003cbr\u003eA: The IR sensor achieves a T90 response time of less than 20 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this unit with Sensepoint probes?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the millivolt interface supports MPD, Sensepoint, Model 705 HT, and PPM sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I calibrate the zero point?\u003c\/strong\u003e\u003cbr\u003eA: Use the magnetic switch on the display or the HART communicator to start zero calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What approvals does this model carry?\u003c\/strong\u003e\u003cbr\u003eA: It carries ATEX and IECEx approvals for use in Zone 1 and Zone 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the shipping weight of this unit?\u003c\/strong\u003e\u003cbr\u003eA: The shipping weight is 5 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a new unit or refurbished?\u003c\/strong\u003e\u003cbr\u003eA: We supply only brand new, original \u003cstrong\u003eHoneywell XNX\u003c\/strong\u003e transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359483310338,"sku":"XNX-AMAV-NNIV1","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMAV-NNIV1.jpg?v=1787281803"},{"product_id":"xnx-amse-nhcb1-honeywell-xnx-transmitter-catalytic-bead","title":"XNX-AMSE-NHCB1 Honeywell XNX Transmitter Catalytic Bead","description":"\u003ch2\u003e\u003cstrong\u003eXNX-AMSE-NHCB1 Honeywell XNX Universal Transmitter Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMSE-NHCB1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e XNX Universal Transmitter with HART over 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX and IECEx certified for explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntry Type:\u003c\/strong\u003e M25 cable entry for secure wiring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e316 stainless steel\u003c\/span\u003e for maximum corrosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Electrochemical cartridge interface with IS barrier and adaptor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Sensors:\u003c\/strong\u003e XNX Toxic and Oxygen sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Catalytic Bead (CB1) for flammable gas detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20mA with \u003cspan style=\"color: #d32f2f;\"\u003eHART\u003c\/span\u003e protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal HART:\u003c\/strong\u003e Installed (H option) for easy configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 20 to 90% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP66 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e Meets EN 61000-6-3 and EN 61000-6-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eXNX-AMSE-NHCB1\u003c\/strong\u003e on a flat, vertical surface using the integral mounting tabs.\u003c\/li\u003e\n\u003cli\u003eUse the optional pipe mount kit for secure installation on 2-inch pipes.\u003c\/li\u003e\n\u003cli\u003eConnect the M25 cable entry with proper sealing to maintain the IP66 rating.\u003c\/li\u003e\n\u003cli\u003eWire the 4-20mA output to a compatible control system or PLC.\u003c\/li\u003e\n\u003cli\u003eUse the HART communicator for remote configuration and diagnostics.\u003c\/li\u003e\n\u003cli\u003ePosition the sensor downward to prevent moisture and dust accumulation.\u003c\/li\u003e\n\u003cli\u003ePerform a zero and span calibration after installation and before first operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eXNX-AMSE-NHCB1\u003c\/strong\u003e Universal Transmitter unit\u003c\/li\u003e\n\u003cli\u003e1 x Catalytic Bead sensor cartridge (CB1)\u003c\/li\u003e\n\u003cli\u003e1 x IS barrier and adaptor for electrochemical sensors\u003c\/li\u003e\n\u003cli\u003e1 x Mounting hardware kit (screws and wall plugs)\u003c\/li\u003e\n\u003cli\u003e1 x Quick start guide (English version)\u003c\/li\u003e\n\u003cli\u003e1 x Product CD with full documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Returns\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship all orders within 5 business days after order confirmation.\u003c\/li\u003e\n\u003cli\u003eWe use FedEx, UPS, and DHL for fast and trackable deliveries.\u003c\/li\u003e\n\u003cli\u003eYou may return the product within 30 days from the delivery date.\u003c\/li\u003e\n\u003cli\u003eWe only supply brand new, original \u003cstrong\u003eHoneywell XNX\u003c\/strong\u003e units.\u003c\/li\u003e\n\u003cli\u003eWe keep this \u003cstrong\u003eXNX-AMSE-NHCB1\u003c\/strong\u003e model in stock for immediate dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What type of sensor does the \u003cstrong\u003eXNX-AMSE-NHCB1\u003c\/strong\u003e use?\u003c\/strong\u003e\u003cbr\u003eA: This \u003cstrong\u003eHoneywell XNX\u003c\/strong\u003e transmitter uses a Catalytic Bead (CB1) sensor for flammable gas detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gases can this transmitter detect?\u003c\/strong\u003e\u003cbr\u003eA: The Catalytic Bead sensor detects a wide range of flammable gases, including methane and LPG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the enclosure material?\u003c\/strong\u003e\u003cbr\u003eA: The enclosure is made of \u003cspan style=\"color: #d32f2f;\"\u003e316 stainless steel\u003c\/span\u003e, offering excellent corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this unit support HART communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNX-AMSE-NHCB1\u003c\/strong\u003e includes local HART for remote configuration and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this unit suitable for outdoor or harsh environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the IP66\/NEMA 4X stainless steel enclosure provides outstanding weather and chemical resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What approvals does this model carry?\u003c\/strong\u003e\u003cbr\u003eA: It carries ATEX and IECEx approvals for use in Zone 1 and Zone 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this with XNX toxic and oxygen sensors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the personality interface supports XNX Toxic and Oxygen sensors with the included IS barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the shipping weight of this unit?\u003c\/strong\u003e\u003cbr\u003eA: The shipping weight is 5 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a new unit or refurbished?\u003c\/strong\u003e\u003cbr\u003eA: We supply only brand new, original \u003cstrong\u003eHoneywell XNX\u003c\/strong\u003e transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359484948738,"sku":"XNX-AMSE-NHCB1","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMSE-NHCB1.jpg?v=1787281971"},{"product_id":"xnx-amse-nnnnn-honeywell-xnx-transmitter-cartridge","title":"XNX-AMSE-NNNNN Honeywell XNX Transmitter Cartridge","description":"\u003ch2\u003e\u003cstrong\u003eXNX-AMSE-NNNNN Honeywell XNX Universal Transmitter with XNXXSH1SS H2S Cartridge\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTransmitter Specifications - XNX-AMSE-NNNNN\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMSE-NNNNN\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e XNX Universal Transmitter with Cartridges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX and IECEx certified for explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntry Type:\u003c\/strong\u003e M25 cable entry for secure wiring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e316 stainless steel\u003c\/span\u003e for maximum corrosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Electrochemical cartridge interface with IS barrier and adaptor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Sensors:\u003c\/strong\u003e XNX Toxic and Oxygen sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20mA with HART protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP66 \/ NEMA 4X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 8 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCartridge Specifications - XNXXSH1SS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003eXNXXSH1SS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electrochemical cartridge for XNX transmitters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage:\u003c\/strong\u003e Analytics XNX Universal Transmitter Fixed Systems Gas Monitors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Gas:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003eHydrogen sulfide (H2S)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e0 to 15 ppm\u003c\/span\u003e (10 to 50 ppm, 1 ppm resolution)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefault Range:\u003c\/strong\u003e 15.0 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u0026lt; +\/-0.3 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 80 kPa to 120 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Air Speed:\u003c\/strong\u003e 0 to 6 m\/sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time (minimum):\u003c\/strong\u003e 60 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.14 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Original brand new\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStorage Conditions for Cartridge\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e 0 to 20°C (32 to 68°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure:\u003c\/strong\u003e 70 to 110 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 30 to 70% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Duration:\u003c\/strong\u003e 6 months maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What gas does the \u003cstrong\u003eXNXXSH1SS\u003c\/strong\u003e cartridge detect?\u003c\/strong\u003e\u003cbr\u003eA: This cartridge detects hydrogen sulfide (H2S) with a range of 0 to 15 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the accuracy of this H2S sensor?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eXNXXSH1SS\u003c\/strong\u003e provides accuracy of \u0026lt; +\/-0.3 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the enclosure material of the transmitter?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eXNX-AMSE-NNNNN\u003c\/strong\u003e uses \u003cspan style=\"color: #d32f2f;\"\u003e316 stainless steel\u003c\/span\u003e for excellent corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this unit support HART communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this \u003cstrong\u003eHoneywell XNX\u003c\/strong\u003e transmitter supports 4-20mA with HART protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the warm-up time for the sensor?\u003c\/strong\u003e\u003cbr\u003eA: The minimum warm-up time is 60 seconds after powering on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What approvals does this transmitter carry?\u003c\/strong\u003e\u003cbr\u003eA: It carries ATEX and IECEx approvals for Zone 1 and Zone 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How should I store the cartridge before use?\u003c\/strong\u003e\u003cbr\u003eA: Store at 0-20°C, 70-110 kPa, and 30-70% RH for up to 6 months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a new unit or refurbished?\u003c\/strong\u003e\u003cbr\u003eA: We supply only brand new, original \u003cstrong\u003eHoneywell\u003c\/strong\u003e products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the shipping weight of the complete package?\u003c\/strong\u003e\u003cbr\u003eA: The transmitter weighs 8 kg and the cartridge weighs 0.14 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48359486324994,"sku":"XNX-AMSE-NNNNN","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMSE-NNNNN.jpg?v=1787282132"},{"product_id":"xnx-amsv-nniv1-honeywell-universal-transmitter-methane","title":"XNX-AMSV-NNIV1 Honeywell Universal Transmitter Methane","description":"\u003ch2\u003e\u003cstrong\u003eXNX-AMSV-NNIV1 Universal Transmitter by Honeywell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell – a global leader in sensing and safety technologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMSV-NNIV1\u003c\/strong\u003e – part of the XNX Universal Transmitter series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e HART® protocol over 4-20mA analog loop for reliable data transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX\/EC certified (Approval code A) for explosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e 316 stainless steel (Material S) with 5 x M25 cable entries (Entry type M).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Interface:\u003c\/strong\u003e mV version (Personality V) for milli-Volt sensors like MPD and Sensepoint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e IR sensor for methane: 0-100% LEL or 0-5% Vol. (Range IV1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.8 kg – robust construction for fixed installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -40°C to +70°C ambient for reliable outdoor use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1% LEL for precise low-level gas detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±2% of full scale ensures accurate readings across the range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e T90 \u0026lt; 10 seconds for rapid hazard alerts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e Meets EN 61000-6-2 and EN 61000-6-4 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eXNX-AMSV-NNIV1\u003c\/strong\u003e vertically on a flat surface using the integral brackets.\u003c\/li\u003e\n\u003cli\u003eConnect the 5 x M25 entries with appropriate cable glands for IP66 protection.\u003c\/li\u003e\n\u003cli\u003eWire the 4-20mA loop with HART® to your control system or PLC.\u003c\/li\u003e\n\u003cli\u003eAttach the compatible mV sensor (MPD, Sensepoint, or Model 705) to the interface.\u003c\/li\u003e\n\u003cli\u003eApply power (24V DC nominal) and verify the output signal before final calibration.\u003c\/li\u003e\n\u003cli\u003ePerform a zero and span calibration using certified methane gas standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Honeywell \u003cstrong\u003eXNX-AMSV-NNIV1\u003c\/strong\u003e universal transmitter unit.\u003c\/li\u003e\n\u003cli\u003e1 x Pre-installed IR sensor for methane (0-100% LEL \/ 0-5% Vol.).\u003c\/li\u003e\n\u003cli\u003e1 x Mounting bracket kit with stainless steel screws.\u003c\/li\u003e\n\u003cli\u003e5 x M25 stainless steel cable glands (fitted).\u003c\/li\u003e\n\u003cli\u003e1 x Quick start guide (multi-language).\u003c\/li\u003e\n\u003cli\u003e1 x Calibration certificate (not for warranty).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Returns\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe stock this item as brand new, original Honeywell stock.\u003c\/li\u003e\n\u003cli\u003eWe ship within 5 business days via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003eYou may return the product within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003eReturned items must be in unused, original packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this transmitter compatible with 3-wire mV sensors?\u003c\/strong\u003e Yes, the mV version (Personality V) supports 3-wire milli-Volt sensors like MPD and Sensepoint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this for other gases besides methane?\u003c\/strong\u003e The IR sensor is factory-set for methane. For other gases, please contact Honeywell for alternative range options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable length for the 4-20mA output?\u003c\/strong\u003e With HART®, we recommend up to 1000 meters using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the transmitter support SIL certification?\u003c\/strong\u003e The \u003cstrong\u003eXNX-AMSV-NNIV1\u003c\/strong\u003e meets SIL 2 requirements for functional safety applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the ambient humidity tolerance?\u003c\/strong\u003e It operates from 0 to 95% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I perform a zero adjustment?\u003c\/strong\u003e Use the magnetic switch or HART® communicator to initiate zero calibration in fresh air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 0.9em; color: #555;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371487801602,"sku":"XNX-AMSV-NNIV1","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMSV-NNIV1.jpg?v=1787537850"},{"product_id":"xnx-amsv-rncb1-honeywell-universal-transmitter","title":"XNX-AMSV-RNCB1 Honeywell Universal Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eXNX-AMSV-RNCB1 Universal Transmitter by Honeywell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell – a trusted name in industrial sensing and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMSV-RNCB1\u003c\/strong\u003e – part of the XNX Universal Transmitter series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e HART® protocol over 4-20mA analog loop for stable communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX\/IEC certified (Approval A) for hazardous area use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e 316 stainless steel (Material S) with 5 x M25 cable entries (Entry M).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Interface:\u003c\/strong\u003e mV version (Personality V) for milli-Volt sensors like MPD and Sensepoint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Catalytic Bead (Range CB1) for combustible gas detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Option:\u003c\/strong\u003e Integrated relay (Option R) for local alarm or actuator control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.0 kg – compact yet rugged for fixed installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C for reliable outdoor performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Resolution:\u003c\/strong\u003e 1% LEL for accurate gas concentration readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±2% of full scale ensures dependable measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e T90 \u0026lt; 10 seconds for fast hazard detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e Complies with EN 61000-6-2 and EN 61000-6-4 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this transmitter compatible with 3-wire catalytic bead sensors?\u003c\/strong\u003e Yes, the mV interface (Personality V) supports standard 3-wire catalytic bead sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this transmitter with a different sensor type?\u003c\/strong\u003e The CB1 range is factory-set for catalytic bead. For other sensors, please contact Honeywell for configuration options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable length for the 4-20mA output?\u003c\/strong\u003e With HART®, we recommend up to 1000 meters using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the relay option support both Normally Open and Normally Closed contacts?\u003c\/strong\u003e Yes, the relay provides both NO and NC dry contacts for flexible control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the ambient humidity tolerance?\u003c\/strong\u003e It operates from 0 to 95% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I perform a zero adjustment for the catalytic bead sensor?\u003c\/strong\u003e Use the magnetic switch or HART® communicator to initiate zero calibration in clean air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this unit SIL rated?\u003c\/strong\u003e The \u003cstrong\u003eXNX-AMSV-RNCB1\u003c\/strong\u003e meets SIL 2 requirements for functional safety applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 0.9em; color: #555;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371489800450,"sku":"XNX-AMSV-RNCB1","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMSV-RNCB1.jpg?v=1787538847"},{"product_id":"xnx-asmsi-rhnnn-honeywell-universal-transmitter","title":"XNX-ASMSI-RHNNN - Honeywell Universal Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eXNX-ASMSI-RHNNN Universal Transmitter by Honeywell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell – a global leader in industrial safety and sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-ASMSI-RHNNN\u003c\/strong\u003e – part of the XNX Universal Transmitter family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e HART® protocol over 4-20mA analog loop for stable signal transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX\/IEC certified (Approval A) for Zone 1 and Zone 2 hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e 316 stainless steel (Material S) with 5 x M25 cable entries (Entry M).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Interface:\u003c\/strong\u003e mV version (Personality V) for milli-Volt sensors like MPD and Sensepoint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Electrochemical H2S sensor (Range RHNNN) for toxic gas detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptions:\u003c\/strong\u003e No relay (R=No), no local HART (N=No), no additional options (N=No).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 3.0 kg – lightweight for easy handling and mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +55°C for reliable indoor and outdoor use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-100 ppm H2S (default) with 0.1 ppm resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±2% of full scale for accurate and repeatable readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e T90 \u0026lt; 25 seconds for rapid toxic gas alerts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e Complies with EN 61000-6-2 and EN 61000-6-4 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this transmitter compatible with 3-wire electrochemical sensors?\u003c\/strong\u003e Yes, the mV interface (Personality V) supports standard 3-wire electrochemical sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this transmitter with a different gas sensor?\u003c\/strong\u003e The RHNNN range is factory-set for H2S. For other gases, please contact Honeywell for alternative configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable length for the 4-20mA output?\u003c\/strong\u003e With HART®, we recommend up to 1000 meters using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this unit include a relay output?\u003c\/strong\u003e No, this model (Option R=No) does not include a relay. Please choose the R option for relay functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the ambient humidity tolerance?\u003c\/strong\u003e It operates from 0 to 95% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I perform a zero adjustment for the H2S sensor?\u003c\/strong\u003e Use the magnetic switch or HART® communicator to initiate zero calibration in fresh air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this unit SIL rated?\u003c\/strong\u003e The \u003cstrong\u003eXNX-ASMSI-RHNNN\u003c\/strong\u003e meets SIL 2 requirements for functional safety applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 0.9em; color: #555;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371503628546,"sku":"XNX-ASMSI-RHNNN","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-ASMSI-RHNNN.jpg?v=1787539601"},{"product_id":"xnx-btai-mhnnn-honeywell-modbus-hart-4-20ma-transmitter","title":"XNX-BTAI-MHNNN Honeywell Modbus HART 4-20mA Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eXNX-BTAI-MHNNN Universal Transmitter by Honeywell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell – a global authority in industrial safety and gas detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-BTAI-MHNNN\u003c\/strong\u003e – part of the XNX Universal Transmitter series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e HART® protocol over 4-20mA analog loop for reliable data transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e Approval B – certified for use in hazardous industrial areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Aluminium (Material A) with ¾\" NPT entries (Entry T) for North American standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Interface I – designed for infrared sensors like Searchline Excel and Searchpoint Optima.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e Modbus (Option M) and Local HART (Option H) for flexible system integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor:\u003c\/strong\u003e No sensor included (Range NNN) – compatible with external 4-20mA devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C (-40°F to +149°F) for extreme environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0-99% RH non-condensing for reliable performance in wet conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 90-110 kPa for normal atmospheric applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -40°C to +75°C (-40°F to 167°F), 0-99% non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16cm x 19.7cm x 11.4cm (6.1\" x 7.8\" x 4.5\") – compact footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.0 kg – lightweight aluminium construction for easy handling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat sensors are compatible with this transmitter?\u003c\/strong\u003e The Interface I personality supports Searchline Excel, Searchpoint Optima, and generic 4-20mA infrared sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this unit include a sensor?\u003c\/strong\u003e No, the NNN range means no sensor is included. You must purchase a compatible sensor separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication protocols does it support?\u003c\/strong\u003e It supports HART® over 4-20mA, Modbus (RS-485), and Local HART for flexible integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this transmitter outdoors?\u003c\/strong\u003e Yes, it operates from -40°C to +65°C with 0-99% RH and 90-110 kPa pressure range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat mounting options are available?\u003c\/strong\u003e Surface mount (standard), pipe mount (optional kit for Ø100-150mm), and ceiling mount (optional bracket).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the difference between Approval A and Approval B?\u003c\/strong\u003e Approval B indicates a different certification scope – please refer to the datasheet for specific zone classifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this unit SIL rated?\u003c\/strong\u003e The \u003cstrong\u003eXNX-BTAI-MHNNN\u003c\/strong\u003e meets SIL 2 requirements for functional safety applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 0.9em; color: #555;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371506086146,"sku":"XNX-BTAI-MHNNN","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-BTAI-MHNNN.jpg?v=1787539768"},{"product_id":"xnx-utae-nnnnn-honeywell-universal-gas-transmitter","title":"XNX-UTAE-NNNNN Honeywell Universal Gas Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-UTAE-NNNNN Universal Gas Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e (Universal Gas Transmitter).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval \u0026amp; Entry:\u003c\/strong\u003e UL-CSA certified (Approval Code U) with ¾\" NPT conduit entry (Entry Type T).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial \u0026amp; Interface:\u003c\/strong\u003e Durable aluminum construction (A) and \u003cspan style=\"color: #0066cc;\"\u003eElectrochemical Cartridge Interface (Ec)\u003c\/span\u003e including IS barrier and adaptor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor \u0026amp; Options:\u003c\/strong\u003e Ships with no sensor installed (NNN) and no optional modules (Option N, Local HART N).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.8 kg (lightweight for easy wall or pole mounting).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003c\/span\u003e Depends on the selected electrochemical sensor (user-configurable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003c\/span\u003e Typically T90 \u0026lt; 30 seconds (sensor dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eSensitivity \u0026amp; Linearity:\u003c\/strong\u003e\u003c\/span\u003e High sensitivity with linear output across the detection range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003c\/span\u003e 0.01 ppm (for most toxic gases) or 0.1% vol for oxygen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -20°C to +50°C (-4°F to +122°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e\u003c\/span\u003e IP66\/IP67 rated; resists humidity, dust, and vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eInterference Rejection:\u003c\/strong\u003e\u003c\/span\u003e Integrated IS barrier minimizes electrical noise and cross-gas interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Mounting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse the ¾\"NPT entry for rigid conduit or cable glands (ensure proper sealing).\u003c\/li\u003e\n\u003cli\u003eMount the \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e vertically on a flat surface using the integrated mounting holes.\u003c\/li\u003e\n\u003cli\u003eConnect the electrochemical sensor cartridge to the Ec interface (adaptor included).\u003c\/li\u003e\n\u003cli\u003eApply power (24 VDC nominal) and verify loop wiring per the user manual.\u003c\/li\u003e\n\u003cli\u003ePerform a zero and span calibration after installation for accurate readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e transmitter unit (aluminum housing).\u003c\/li\u003e\n\u003cli\u003eElectrochemical interface module with IS barrier and adaptor.\u003c\/li\u003e\n\u003cli\u003eMounting hardware kit (screws and wall plugs).\u003c\/li\u003e\n\u003cli\u003eQuick start guide and terminal block connectors.\u003c\/li\u003e\n\u003cli\u003e(Sensor sold separately – order the required MPD sensor cartridge).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe stock this model – ready for immediate dispatch.\u003c\/li\u003e\n\u003cli\u003eShip within 5 business days via \u003cstrong\u003eFedEx, UPS, or DHL\u003c\/strong\u003e (your choice).\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and factory sealed.\u003c\/li\u003e\n\u003cli\u003e30-day return window for unused items in original packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e come with a sensor?\u003c\/strong\u003e\u003cbr\u003eA: No, it ships without a sensor (NNN). You need to purchase the appropriate electrochemical cartridge separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this transmitter for oxygen detection?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the Ec interface supports Honeywell oxygen sensors as well as toxic gas cartridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the warranty period?\u003c\/strong\u003e\u003cbr\u003eA: The transmitter carries a standard 12-month warranty against manufacturing defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the unit intrinsically safe?\u003c\/strong\u003e\u003cbr\u003eA: The included IS barrier and adaptor (Ec personality) provide intrinsic safety for hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I calibrate the \u003cstrong\u003eXNX-UTAE-NNNNN\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eA: Use the local HART (optional) or a handheld calibrator; follow the step-by-step guide in the manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum cable distance?\u003c\/strong\u003e\u003cbr\u003eA: Up to 300 meters (1,000 ft) with shielded cable, depending on the sensor type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003c\/strong\u003e\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371510018306,"sku":"XNX-UTAE-NNNNN","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTAE-NNNNN.jpg?v=1787540028"},{"product_id":"xnx-utai-nhnnn-honeywell-explosion-proof-transmitter","title":"XNX-UTAI-NHNNN Honeywell Explosion-Proof Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTAI-NHNNN Explosion-Proof Universal Transmitter by Honeywell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell – a global leader in sensing and safety technologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-UTAI-NHNNN\u003c\/strong\u003e – part of the reliable XNX series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20mA with HART® digital communication overlay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e Local HART® port for easy on-site configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e Painted aluminium, suitable for corrosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion Proof Rating:\u003c\/strong\u003e Certified for use in hazardous locations (ATEX\/IECEx).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Pre-configured for Honeywell Optima Plus and Excel gas detectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC nominal (range 18-32 VDC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C for extreme environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -50°C to +80°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 0-95% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±1% of full scale (linearity and repeatability).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.01 mA for precise signal reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 2 seconds to 90% of step change.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e Meets EN 61000-6-2 and 61000-6-4 standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP66\/67, dust-tight and water-resistant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this transmitter compatible with other sensors?\u003c\/strong\u003e\u003cbr\u003eThis unit is pre-configured for Optima Plus and Excel. It may not work with other sensors without reconfiguration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this device in a Zone 1 hazardous area?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003eXNX-UTAI-NHNNN\u003c\/strong\u003e carries an explosion-proof certification suitable for Zone 1 and Zone 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable length for the 4-20mA loop?\u003c\/strong\u003e\u003cbr\u003eKeep the loop cable under 1000 meters for reliable HART® communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the unit support both analog and digital outputs?\u003c\/strong\u003e\u003cbr\u003eYes, it provides a 4-20mA analog signal with HART® digital data overlays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this model available in stainless steel housing?\u003c\/strong\u003e\u003cbr\u003eNo, this version features a painted aluminium housing. Check other XNX variants for stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I perform a zero calibration on this transmitter?\u003c\/strong\u003e\u003cbr\u003eUse the local HART® interface or a handheld communicator to initiate calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have these transmitters in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we maintain stock for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return this product if it doesn't fit my application?\u003c\/strong\u003e\u003cbr\u003eWe accept returns within 30 days from delivery, subject to our return policy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/861539249628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371521683714,"sku":"XNX-UTAI-NHNNN","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTAI-NHNNN.jpg?v=1787540408"},{"product_id":"xnx-utav-nncb1-honeywell-gas-detector-transmitter-catalytic-bead","title":"XNX-UTAV-NNCB1 Honeywell Gas Detector Transmitter Catalytic Bead","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTAV-NNCB1 Explosion-Proof Universal Gas Detector Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell – a trusted name in gas detection and safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-UTAV-NNCB1\u003c\/strong\u003e – part of the advanced XNX series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Universal gas detector transmitter with MPD catalytic bead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e UL and CSA certified for hazardous locations (Class I, Div 1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Entry:\u003c\/strong\u003e ¾\" NPT thread for standard industrial fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Painted aluminium for corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality Interface:\u003c\/strong\u003e mV input for millivolt sensors (MPD, Sensepoint, 705 series).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e Intrinsic safety barrier and adaptor for XNX toxic\/oxygen sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal HART:\u003c\/strong\u003e Not installed (field upgrade available).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Catalytic bead (CB1) – fast response to hydrocarbons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Sensors:\u003c\/strong\u003e Honeywell 705, 705HT, Sensepoint, Sensepoint HT, and MPD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Gases:\u003c\/strong\u003e Wide range of flammable gases and hydrocarbons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 5 seconds to 50% LEL for most hydrocarbons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20 mA analog (non-HART version).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0-99% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC nominal (12-32 VDC range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e 0-100% LEL (lower explosive limit).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±2% of full scale at calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP66\/67 weatherproof and dust-tight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this transmitter compatible with oxygen or toxic sensors?\u003c\/strong\u003e\u003cbr\u003eYes, the personality interface includes a barrier and adaptor for XNX toxic\/oxygen electrochemical cartridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this transmitter with a Sensepoint HT sensor?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003eXNX-UTAV-NNCB1\u003c\/strong\u003e supports Sensepoint HT, 705HT, and standard Sensepoint models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this unit have HART communication?\u003c\/strong\u003e\u003cbr\u003eNo, this version does not include the local HART option. You can order an upgrade kit separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the detection range for methane?\u003c\/strong\u003e\u003cbr\u003eFor methane, the catalytic bead sensor provides 0-100% LEL (5% volume).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this transmitter suitable for outdoor use?\u003c\/strong\u003e\u003cbr\u003eYes, it features IP66\/67 and a painted aluminium housing for outdoor harsh conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock for the \u003cstrong\u003eXNX-UTAV-NNCB1\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eYes, we maintain regular stock. Contact us for current availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the return policy?\u003c\/strong\u003e\u003cbr\u003eWe accept returns within 30 days of delivery, subject to our return guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/861539249628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371580174594,"sku":"XNX-UTAV-NNCB1","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTAV-NNCB1.jpg?v=1787541781"},{"product_id":"xnx-utav-nnic1-infrared-gas-detector-honeywell","title":"XNX-UTAV-NNIC1 Infrared Gas Detector - Honeywell","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTAV-NNIC1 Infrared CO2 Universal Gas Detector Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell – a global leader in gas detection technologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-UTAV-NNIC1\u003c\/strong\u003e – part of the versatile XNX transmitter series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Universal gas detector with MPD infrared CO2 sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5% V\/V (volume per volume) carbon dioxide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Technology:\u003c\/strong\u003e Non-dispersive infrared (NDIR) for selective CO2 sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e UL and CSA certified for Class I, Division 1 hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Entries:\u003c\/strong\u003e Four 3\/4\" NPT openings for easy field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Painted aluminium with excellent corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20 mA analog with HART® digital protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal HART:\u003c\/strong\u003e Not installed (optional upgrade available).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC nominal (range 18-32 VDC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +55°C for reliable indoor\/outdoor use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 0-95% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±2% of full scale at calibration conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 30 seconds to 90% of step change.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP66\/67 weatherproof and dust-tight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e Meets EN 61000-6-2 and 61000-6-4.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the transmitter vertically on a stable wall or pipe support.\u003c\/li\u003e\n\u003cli\u003eUse all four 3\/4\" NPT entries for power, signal, and sensor connections.\u003c\/li\u003e\n\u003cli\u003eSeal unused entries with approved explosion-proof plugs.\u003c\/li\u003e\n\u003cli\u003eConnect the 4-20 mA loop to a PLC, DCS, or SCADA input module.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding to prevent electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eAllow 5 minutes for sensor stabilisation after power-up.\u003c\/li\u003e\n\u003cli\u003ePerform a zero calibration using nitrogen or CO2-free air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Honeywell \u003cstrong\u003eXNX-UTAV-NNIC1\u003c\/strong\u003e transmitter with CO2 sensor.\u003c\/li\u003e\n\u003cli\u003e1 x mounting bracket kit with screws and wall plugs.\u003c\/li\u003e\n\u003cli\u003e1 x quick start wiring diagram (English version).\u003c\/li\u003e\n\u003cli\u003eNo calibration gas or certificates are supplied with this package.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide using FedEx, UPS, or DHL express services.\u003c\/li\u003e\n\u003cli\u003eAll orders dispatch within 5 business days from our facility.\u003c\/li\u003e\n\u003cli\u003eEvery unit is brand new, factory-calibrated, and sealed.\u003c\/li\u003e\n\u003cli\u003eYou will receive tracking information via email after shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat gases does this transmitter detect?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eXNX-UTAV-NNIC1\u003c\/strong\u003e specifically measures carbon dioxide (CO2) in the 0-5% V\/V range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this transmitter in a Zone 1 hazardous area?\u003c\/strong\u003e\u003cbr\u003eYes, the UL\/CSA approval covers Class I, Division 1 and Zone 1 installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this model include HART communication?\u003c\/strong\u003e\u003cbr\u003eYes, it supports HART® protocol over the 4-20 mA output for digital diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the infrared sensor affected by oxygen or humidity?\u003c\/strong\u003e\u003cbr\u003eThe NDIR sensor is selective for CO2 and largely immune to oxygen and moisture interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the expected sensor life?\u003c\/strong\u003e\u003cbr\u003eThe infrared sensor typically operates for 5-7 years under normal conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have the \u003cstrong\u003eXNX-UTAV-NNIC1\u003c\/strong\u003e in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we maintain inventory for immediate shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return this product if it does not suit my application?\u003c\/strong\u003e\u003cbr\u003eWe accept returns within 30 days of delivery, subject to our return policy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/861539249628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371585286402,"sku":"XNX-UTAV-NNIC1","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTAV-NNIC1.jpg?v=1787541994"},{"product_id":"xnx-utav-nniv1-honeywell-gas-detector-hydrocarbon-sensor","title":"XNX-UTAV-NNIV1 Honeywell Gas Detector Hydrocarbon Sensor","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-UTAV-NNIV1 Multi-Purpose Gas Detector\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNX-UTAV-NNIV1\u003c\/strong\u003e. This MPD unit delivers reliable gas detection for industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e Accepts mV (catalytic bead and IR cell), electrochemical cell, and IR (point and open-path) sensors. The included \u003cstrong\u003eXNX-UTAV-NNIV1\u003c\/strong\u003e version features the IV1 IR sensor for methane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0–100% LEL (or 0–5% Vol.) methane. Provides accurate readings for leak detection and safety monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e Standard 4-20 mA with HART® protocol. Supports 3 or 4-wire operation in source, sink, or isolated modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e Up to 3 relays, MODBUS®, and FOUNDATION® H1 Fieldbus (pending). Optional local IS port for handheld HART configurator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Rating:\u003c\/strong\u003e NEMA 4X IP66 rated. Suitable for rugged indoor and outdoor use. Resists dust, water, and corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Aluminum construction with ¾\" NPT conduit entry. Durable and lightweight at 2.8 Kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL and CSA certified (U = UL-CSA). Meets North American safety standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16 x 19.7 x 11.4 inches (HxWxD). Compact design fits tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Simple plug-in sensors and replaceable cells. Use with conduit or cable installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e XNX-UTAV-NNIV1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Multi-Purpose Gas Detector (MPD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e IR (IV1) for Methane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Range:\u003c\/strong\u003e 0-100% LEL or 0-5% Vol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 4-20 mA with HART® (standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Up to 3 optional\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Protocols:\u003c\/strong\u003e MODBUS®, FOUNDATION® H1 (pending)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e NEMA 4X, IP66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntry Type:\u003c\/strong\u003e ¾\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.8 Kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16\" x 19.7\" x 11.4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e UL-CSA (U)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e 3 or 4-wire, source\/sink\/isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal HART:\u003c\/strong\u003e Optional IS port (not installed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this detector brand new?\u003c\/strong\u003e Yes, we supply only brand new, factory-sealed Honeywell \u003cstrong\u003eXNX-UTAV-NNIV1\u003c\/strong\u003e units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock available?\u003c\/strong\u003e Yes, we have ample stock. We ship most orders within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the warranty period?\u003c\/strong\u003e The product includes a 12-month manufacturer warranty. We also support 30-day returns for any defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this detector for other gases?\u003c\/strong\u003e The \u003cstrong\u003eXNX-UTAV-NNIV1\u003c\/strong\u003e supports mV, catalytic, electrochemical, and IR sensors. You can change the sensor for different gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication protocols does it support?\u003c\/strong\u003e Standard HART®, optional MODBUS® and FOUNDATION® H1 (pending). Up to 3 relays available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the detector suitable for outdoor use?\u003c\/strong\u003e Yes, the NEMA 4X IP66 rating makes it rugged for indoor and outdoor harsh environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I connect the wiring?\u003c\/strong\u003e Use 3 or 4-wire configuration. Choose source, sink, or isolated mode to match your control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the product if it doesn't fit?\u003c\/strong\u003e Yes, we offer a 30-day return policy. Contact our support team for authorization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the measuring range for methane?\u003c\/strong\u003e The IR sensor provides 0-100% LEL or 0-5% Vol. methane detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you provide technical support?\u003c\/strong\u003e Yes, our team can assist with installation, configuration, and troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e |\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371597050114,"sku":"XNX-UTAV-NNIV1","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTAV-NNIV1.jpg?v=1787542195"},{"product_id":"xnx-utse-nhnnn-honeywell-universal-transmitter-4-20ma","title":"XNX-UTSE-NHNNN Honeywell Universal Transmitter 4-20mA","description":"\u003ch2\u003e\n\u003cstrong\u003eHoneywell XNX-UTSE-NHNNN Universal Transmitter\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e XNX-UTSE-NHNNN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e XNX Universal Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Interface:\u003c\/strong\u003e Electrochemical (E personality) with IS barrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20 mA with local HART®\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e NEMA 4X, IP66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e 316 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Entry:\u003c\/strong\u003e ¾\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e UL-CSA (U)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +75°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0-99% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure:\u003c\/strong\u003e 90-110 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.0 Kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Surface, pipe (optional), or ceiling (optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this transmitter brand new?\u003c\/strong\u003e Yes, we supply only brand new, factory-sealed Honeywell \u003cstrong\u003eXNX-UTSE-NHNNN\u003c\/strong\u003e units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock available?\u003c\/strong\u003e Yes, we have ample stock. We ship most orders within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the warranty period?\u003c\/strong\u003e The product includes a 12-month manufacturer warranty. We also support 30-day returns for any defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat sensors work with this transmitter?\u003c\/strong\u003e The \u003cstrong\u003eXNX-UTSE-NHNNN\u003c\/strong\u003e accepts electrochemical cartridges for toxic and oxygen gases. The sensor is sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it support HART communication?\u003c\/strong\u003e Yes, this version includes local HART (H option). You can configure it via a handheld communicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the housing corrosion-resistant?\u003c\/strong\u003e Yes, the 316 stainless steel housing provides excellent resistance to corrosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e It operates from -40°C to +65°C (-40°F to +149°F), suitable for extreme environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I mount it on a pipe?\u003c\/strong\u003e Yes, an optional pipe mounting kit is available for Ø100-150mm pipes. Surface mounting is standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the IP rating?\u003c\/strong\u003e The unit has NEMA 4X IP66 rating, making it dust-tight and water-resistant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you provide technical support?\u003c\/strong\u003e Yes, our team can assist with installation, configuration, and troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/861539249628\"\u003ePhone +86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48371600163074,"sku":"XNX-UTSE-NHNNN","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTSE-NHNNN.jpg?v=1787542439"},{"product_id":"xnx-utse-nnnnn-honeywell-transmitter-stainless-steel-ul-csa","title":"XNX-UTSE-NNNNN Honeywell Transmitter Stainless Steel UL\/CSA","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTSE-NNNNN Honeywell Stainless Steel Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNX-UTSE-NNNNN\u003c\/strong\u003e – XNX Series Stainless Steel Transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20mA analog with HART® digital communication overlay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e Configured for Honeywell XNX toxic and oxygen sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e Rugged stainless steel for superior corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Entries:\u003c\/strong\u003e Four 3\/4\" NPT conduit openings for easy field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL\/CSA certified for North American hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Depends on the installed XNX sensor (0-100% LEL, ppm, or %VOL).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e T90 response time typically under 30 seconds for most gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e High sensitivity down to 1 ppm for many toxic gas types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±2% of full scale across the entire measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1 ppm or 0.1% LEL depending on sensor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -40°C to +70°C for reliable outdoor and indoor use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e IP66\/IP67 rated against dust and water ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e Excellent resistance to RFI\/EMI interference per EN 61000-6-2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this transmitter compatible with my existing XNX sensors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNX-UTSE-NNNNN\u003c\/strong\u003e works with all Honeywell XNX toxic and oxygen sensor heads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum cable distance for the 4-20mA loop?\u003c\/strong\u003e\u003cbr\u003eA: You can run up to 1000 meters using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this transmitter in a Zone 1 hazardous area?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the UL\/CSA certification covers Class I, Division 1 groups B, C, D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the unit support HART® multivariable data?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the HART® protocol provides digital process variable and diagnostic data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I perform a zero calibration?\u003c\/strong\u003e\u003cbr\u003eA: Apply zero gas (nitrogen or clean air) and use the magnetic switch or HART®.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the warranty period for this product?\u003c\/strong\u003e\u003cbr\u003eA: We offer a 30-day return policy and full manufacturer's warranty coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is there a display option for local reading?\u003c\/strong\u003e\u003cbr\u003eA: This model does not include a display; it relies on the 4-20mA\/HART® output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I clean the stainless steel housing?\u003c\/strong\u003e\u003cbr\u003eA: Use a soft cloth with mild detergent; avoid abrasive or acidic cleaners.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/861539249628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375122690306,"sku":"XNX-UTSE-NNNNN","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTSE-NNNNN.jpg?v=1787624173"},{"product_id":"xnx-utsv-nnic1-honeywell-universal-transmitter","title":"XNX-UTSV-NNIC1 Honeywell Universal Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTSV-NNIC1 Honeywell Universal Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNX-UTSV-NNIC1\u003c\/strong\u003e – XNX Universal Transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e UL\/CSA certified for North American hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e 316 stainless steel for superior corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e mV interface for milli-Volt sensors (MPD, Sensepoint, Model 705).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor \u0026amp; Range:\u003c\/strong\u003e IC1 = IR Carbon Dioxide 0-5% Vol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Entries:\u003c\/strong\u003e Four 3\/4\" NPT conduit openings for easy field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-5% Vol. CO₂ with the pre-configured IC1 sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e T90 response time typically under 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e High sensitivity for low-level CO₂ detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±2% of full scale across the entire measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.01% Vol. for precise carbon dioxide readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C (-40°F to +149°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0-99% RH (non-condensing) for harsh environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 90-110 kPa for atmospheric compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -40°C to 75°C (-40°F to 167°F), 0-99% non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e Excellent resistance to RFI\/EMI interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which sensors work with this transmitter?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eXNX-UTSV-NNIC1\u003c\/strong\u003e supports MPD, Sensepoint, and Model 705 HT and PPM sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum cable distance for the mV sensor?\u003c\/strong\u003e\u003cbr\u003eA: You can run up to 300 meters using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this in a Zone 1 hazardous area?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the UL\/CSA certification covers Class I, Division 1 groups B, C, D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the unit support HART® communication?\u003c\/strong\u003e\u003cbr\u003eA: This model has no local HART option installed (N = No Option).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I perform a zero calibration?\u003c\/strong\u003e\u003cbr\u003eA: Apply zero gas (nitrogen or CO₂-free air) and use the magnetic switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the warranty period for this product?\u003c\/strong\u003e\u003cbr\u003eA: We offer a 30-day return policy and full manufacturer's warranty coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is pipe mounting kit included in the package?\u003c\/strong\u003e\u003cbr\u003eA: No, the pipe mounting kit is optional and sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I clean the stainless steel housing?\u003c\/strong\u003e\u003cbr\u003eA: Use a soft cloth with mild detergent; avoid abrasive or acidic cleaners.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/861539249628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375123837186,"sku":"XNX-UTSV-NNIC1","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTSV-NNIC1.jpg?v=1787624548"},{"product_id":"xnx-utsv-nniv1-honeywell-methane-transmitter-0-100-lel-ir","title":"XNX-UTSV-NNIV1 Honeywell Methane Transmitter 0-100% LEL IR","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTSV-NNIV1 Honeywell Universal Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNX-UTSV-NNIV1\u003c\/strong\u003e – XNX Universal Transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e UL\/CSA certified for North American hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e 316 stainless steel for superior corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e mV interface for milli-Volt sensors (MPD, Sensepoint, Model 705).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor \u0026amp; Range:\u003c\/strong\u003e IV1 = IR 0-100% LEL (or 0-5% Vol.) Methane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Entries:\u003c\/strong\u003e Four 3\/4\" NPT conduit openings for easy field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-100% LEL or 0-5% Vol. Methane (IR sensor).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e T90 response time typically under 30 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e High sensitivity for low-level methane detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±2% of full scale across the entire measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1% LEL or 0.01% Vol. for precise readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C (-40°F to +149°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0-99% RH (non-condensing) for harsh environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 90-110 kPa for atmospheric compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -40°C to 75°C (-40°F to 167°F), 0-99% non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e Excellent resistance to RFI\/EMI interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.8 kg – robust and durable construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16 cm x 19.7 cm x 11.4 cm (6.1\" x 7.8\" x 4.5\").\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the transmitter on a flat surface using integral mounting lugs.\u003c\/li\u003e\n\u003cli\u003eUse the optional pipe mounting kit for Ø100-150mm (Ø4\"-6\") pipes.\u003c\/li\u003e\n\u003cli\u003eSelect the ceiling mounting bracket for overhead installations.\u003c\/li\u003e\n\u003cli\u003eConnect the milli-Volt sensor wires to the designated terminals.\u003c\/li\u003e\n\u003cli\u003eApply power only after verifying correct sensor and wiring connections.\u003c\/li\u003e\n\u003cli\u003ePerform a zero and span calibration after installation is complete.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003eXNX-UTSV-NNIV1\u003c\/strong\u003e stainless steel universal transmitter.\u003c\/li\u003e\n\u003cli\u003ePre-installed IV1 IR methane sensor (0-100% LEL or 0-5% Vol.).\u003c\/li\u003e\n\u003cli\u003eMounting lugs and hardware for surface installation.\u003c\/li\u003e\n\u003cli\u003eInstruction manual and quick-start guide.\u003c\/li\u003e\n\u003cli\u003eTerminal block connectors and spare fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship all orders via FedEx, UPS, or DHL express services.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and original from Honeywell.\u003c\/li\u003e\n\u003cli\u003eWe maintain ample stock for immediate dispatch.\u003c\/li\u003e\n\u003cli\u003eOrders ship within 5 business days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003eWe provide tracking numbers for all shipments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which sensors work with this transmitter?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eXNX-UTSV-NNIV1\u003c\/strong\u003e supports MPD, Sensepoint, and Model 705 HT and PPM sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum cable distance for the mV sensor?\u003c\/strong\u003e\u003cbr\u003eA: You can run up to 300 meters using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this in a Zone 1 hazardous area?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the UL\/CSA certification covers Class I, Division 1 groups B, C, D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the unit support HART® communication?\u003c\/strong\u003e\u003cbr\u003eA: This model has no local HART option installed (N = No Option).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I perform a zero calibration?\u003c\/strong\u003e\u003cbr\u003eA: Apply zero gas (nitrogen or methane-free air) and use the magnetic switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the warranty period for this product?\u003c\/strong\u003e\u003cbr\u003eA: We offer a 30-day return policy and full manufacturer's warranty coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is pipe mounting kit included in the package?\u003c\/strong\u003e\u003cbr\u003eA: No, the pipe mounting kit is optional and sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I clean the stainless steel housing?\u003c\/strong\u003e\u003cbr\u003eA: Use a soft cloth with mild detergent; avoid abrasive or acidic cleaners.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/861539249628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375126851842,"sku":"XNX-UTSV-NNIV1","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTSV-NNIV1.jpg?v=1787624841"},{"product_id":"xnx-amav-nnif1-honeywell-ir-propane-detector","title":"XNX-AMAV-NNIF1 Honeywell IR Propane Detector","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-AMAV-NNIF1 IR Propane Gas Detector\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e – EC\/mV version accepts 16V to 32V DC, nominal 24V. IR version operates from 18V to 32V DC, nominal 24V. Startup and normal values remain stable within these ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal output\u003c\/strong\u003e – Standard configuration provides HART over 3-wire 4-20 mA (sink, source, or isolated). Optional Modbus over RS-485 offers digital communication flexibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent loop\u003c\/strong\u003e – 20 mA output follows HART protocol over 3-wire 4-20 mA. It complies fully with NAMUR NE43 for reliable fault signalling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entries\u003c\/strong\u003e – Five ports in total: two right, two left, and one bottom. Choose either 3\/4\" NPT or M25 thread options to suit your installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnpowered clock\u003c\/strong\u003e – The real-time clock retains settings for three years at rated storage temperature, without external power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterials\u003c\/strong\u003e – Marine grade aluminium alloy or SS316 enclosure. A five-coat painted finish provides extra corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental ratings\u003c\/strong\u003e – IP66 protects against dust and powerful water jets. Humidity tolerance covers 0 to 99% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure \u0026amp; air speed\u003c\/strong\u003e – Operating pressure range spans 80 kPa to 120 kPa. It withstands air speeds from 0 to 6 metres per second.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e – The unit weighs 5 kilograms, offering a sturdy yet manageable installation mass.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines for the XNX-AMAV-NNIF1\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the detector in areas with potential propane leaks, but avoid direct sunlight or heat sources.\u003c\/li\u003e\n\u003cli\u003eUse the five cable ports (right, left, bottom) to route wiring conveniently. Select 3\/4\" NPT or M25 fittings as per your conduit system.\u003c\/li\u003e\n\u003cli\u003eProvide a stable 24V DC nominal supply. Ensure voltage stays within the specified startup and normal ranges.\u003c\/li\u003e\n\u003cli\u003eChoose the 4-20 mA with HART or RS-485 Modbus output based on your control system’s protocol.\u003c\/li\u003e\n\u003cli\u003eSecure the enclosure properly – its IP66 rating only works with correctly sealed cable glands.\u003c\/li\u003e\n\u003cli\u003eCalibrate the sensor after installation using the recommended zero and span gases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List – XNX-AMAV-NNIF1\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell XNX-AMAV-NNIF1 IR propane gas detector unit\u003c\/li\u003e\n\u003cli\u003eMounting bracket kit with stainless steel hardware\u003c\/li\u003e\n\u003cli\u003eProtective cap for the sensor element (shipping cap)\u003c\/li\u003e\n\u003cli\u003eQuick start guide and product manual (digital download)\u003c\/li\u003e\n\u003cli\u003eCable gland adapters for 3\/4\" NPT or M25 (depending on order)\u003c\/li\u003e\n\u003cli\u003eTest certificate for factory calibration (no warranty terms)\u003c\/li\u003e\n\u003cli\u003eDesiccant pack and spare O-ring seals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the XNX-AMAV-NNIF1 brand new and original?\u003c\/strong\u003e – Yes, we supply only genuine Honeywell new units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this model in stock?\u003c\/strong\u003e – Yes, we keep the \u003cstrong\u003eXNX-AMAV-NNIF1\u003c\/strong\u003e in our warehouse ready for dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast can you ship?\u003c\/strong\u003e – We process orders within 5 working days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich carriers do you use?\u003c\/strong\u003e – We ship via FedEx, UPS, or DHL, depending on your region.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the detector?\u003c\/strong\u003e – We support returns within 30 days of delivery, subject to inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat power supply do I need?\u003c\/strong\u003e – Use a 24V nominal DC source (16-32V for EC\/mV, 18-32V for IR version).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the 4-20 mA output isolated?\u003c\/strong\u003e – Yes, the standard HART output supports sink, source, or isolated modes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 14px; color: #555; margin-top: 20px;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\" style=\"color: #0066cc;\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\" style=\"color: #0066cc;\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\" style=\"color: #0066cc;\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375134945538,"sku":"XNX-AMAV-NNIF1","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMAV-NNIF1.jpg?v=1787625429"},{"product_id":"02104-n-xmaa-honeywell-xnx-gas-detector","title":"02104-N-XMAA Honeywell XNX Gas Detector","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell 02104-N-XMAA Line-of-Sight Gas Detection System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection range\u003c\/strong\u003e – Covers distances from 5 metres up to 40 metres, suitable for open-path gas sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput signals\u003c\/strong\u003e – Provides standard 4-20 mA analogue output with integrated HART® communication for digital diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e – Holds ATEX and IECEx approvals for use in hazardous areas. Safe for Zone 1 and Zone 2 environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure material\u003c\/strong\u003e – Features electro-polished 316L stainless steel for maximum corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJunction box\u003c\/strong\u003e – Includes a stainless steel XNX Ex e junction box with dual M20\/M25 cable entries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting hardware\u003c\/strong\u003e – Supplies 316SS mounting plates, brackets, and all necessary stainless steel hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e – Ships fully wired with flexible conduit, reducing your installation time and effort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem components\u003c\/strong\u003e – Complete set includes both transmitter (Tx) and receiver (Rx) units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the 02104-N-XMAA a genuine Honeywell new unit?\u003c\/strong\u003e – Yes, we supply only brand new, original Honeywell systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this model in stock?\u003c\/strong\u003e – Yes, we keep the \u003cstrong\u003e02104-N-XMAA\u003c\/strong\u003e in our warehouse for immediate orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow fast can you ship?\u003c\/strong\u003e – We dispatch all orders within 5 working days after payment confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich carriers do you use?\u003c\/strong\u003e – We ship via FedEx, UPS, or DHL, depending on your location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the system?\u003c\/strong\u003e – We accept returns within 30 days of delivery, subject to our return policy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum detection distance?\u003c\/strong\u003e – This system reliably detects gas across 5 to 40 metres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the junction box suitable for Zone 1?\u003c\/strong\u003e – Yes, the Ex e enclosure meets ATEX and IECEx requirements for Zone 1 and Zone 2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 14px; color: #555; margin-top: 20px;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\" style=\"color: #0066cc;\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\" style=\"color: #0066cc;\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\" style=\"color: #0066cc;\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375172759810,"sku":"02104-N-XMAA","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/02104-N-XMAA.jpg?v=1787626143"},{"product_id":"xnxamainhnnn-honeywell-gas-detector-transmitter-system","title":"XNXAMAINHNNN Honeywell Gas Detector Transmitter System","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell 2108N4000N + XNXAMAINHNNN Gas Detection System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003e2108N4000N\u003c\/strong\u003e with \u003cstrong\u003eXNXAMAINHNNN\u003c\/strong\u003e transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX and IEC certified for hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Entry:\u003c\/strong\u003e M25 cable gland type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Options:\u003c\/strong\u003e Aluminium (4.4 kg \/ 9.7 lbs) or Stainless Steel (6.8 kg \/ 15 lbs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Interface for infrared products like Searchline Excel and Searchpoint Optima. Also supports generic 4-20mA inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Local HART protocol enabled (H option).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Hydrocarbon calibration with dust barrier and weather housing. Includes a deluge\/heat shade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Transmitter weighs 1.6 kg. Total system weight varies by material.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Depends on the connected infrared sensor (Searchline Excel, Searchpoint Optima).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Fast response to target gas concentrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e High sensitivity for low-level gas detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Excellent linearity across the full measurement scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e Provides high-resolution output for accurate readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Operates reliably in extreme industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Withstands dust, moisture, and deluge conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e Strong resistance to electromagnetic and radio frequency interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eXNXAMAINHNNN\u003c\/strong\u003e transmitter in a stable, accessible location.\u003c\/li\u003e\n\u003cli\u003eUse the M25 entry for secure cable connections.\u003c\/li\u003e\n\u003cli\u003eInstall the weather housing and deluge shade for outdoor protection.\u003c\/li\u003e\n\u003cli\u003eConnect the infrared sensor or 4-20mA device to the personality interface.\u003c\/li\u003e\n\u003cli\u003eConfigure the local HART for communication with your control system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003e2108N4000N\u003c\/strong\u003e hydrocarbon transmitter unit.\u003c\/li\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003eXNXAMAINHNNN\u003c\/strong\u003e universal transmitter.\u003c\/li\u003e\n\u003cli\u003ePre-installed dust barrier.\u003c\/li\u003e\n\u003cli\u003eWeather housing and deluge\/heat shade.\u003c\/li\u003e\n\u003cli\u003eMounting hardware and M25 cable gland.\u003c\/li\u003e\n\u003cli\u003eUser manual and quick start guide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this a new original unit?\u003c\/strong\u003e Yes, we supply brand new, original Honeywell products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have stock available?\u003c\/strong\u003e Yes, we maintain stock for immediate dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen will you ship my order?\u003c\/strong\u003e We ship all orders within 5 working days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich couriers do you use?\u003c\/strong\u003e We ship via FedEx, UPS, and DHL for reliable delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the product?\u003c\/strong\u003e Yes, we support a 30-day return policy for unused items.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e The system operates from -40°C to +70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it support HART communication?\u003c\/strong\u003e Yes, the \u003cstrong\u003eXNXAMAINHNNN\u003c\/strong\u003e includes local HART (H option).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375178297602,"sku":"XNXAMAINHNNN","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXAMAINHNNN.jpg?v=1787626404"},{"product_id":"xnx-amsv-nhcb1-honeywell-universal-gas-transmitter-atex","title":"XNX-AMSV-NHCB1 Honeywell Universal Gas Transmitter ATEX","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-AMSV-NHCB1 Universal Gas Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMSV-NHCB1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Universal gas transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Painted 316 stainless steel for superior corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e ATEX and IEC certified for hazardous zone operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entries:\u003c\/strong\u003e Five M25 entries for flexible wiring connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e Standard 4-20mA output with HART protocol for digital communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Interface:\u003c\/strong\u003e Includes a local HART interface port for easy configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e MPD flammable catalytic sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 to 100% LEL (Lower Explosive Limit).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-100% LEL for flammable gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Rapid response to target gas presence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e High sensitivity for early leak detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Excellent linearity across the entire 0-100% LEL scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e Fine resolution for precise low-level readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Wide temperature range for harsh industrial settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Robust against dust, moisture, and corrosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e Strong resistance to EMI and RFI interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eXNX-AMSV-NHCB1\u003c\/strong\u003e in a stable, upright position.\u003c\/li\u003e\n\u003cli\u003eUtilize the five M25 entries for cable glands and conduit connections.\u003c\/li\u003e\n\u003cli\u003eConnect the 4-20mA output to your control or monitoring system.\u003c\/li\u003e\n\u003cli\u003eUse the local HART port for calibration and device configuration.\u003c\/li\u003e\n\u003cli\u003eEnsure the MPD catalytic sensor faces the potential gas source.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003eXNX-AMSV-NHCB1\u003c\/strong\u003e universal gas transmitter.\u003c\/li\u003e\n\u003cli\u003ePre-installed MPD flammable catalytic sensor (0-100% LEL).\u003c\/li\u003e\n\u003cli\u003eMounting bracket and hardware kit.\u003c\/li\u003e\n\u003cli\u003eFive M25 cable gland adapters.\u003c\/li\u003e\n\u003cli\u003eQuick start guide and product documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this a brand new unit?\u003c\/strong\u003e Yes, we supply only new, original Honeywell transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this in stock?\u003c\/strong\u003e Yes, we keep the \u003cstrong\u003eXNX-AMSV-NHCB1\u003c\/strong\u003e in stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow quickly will you ship?\u003c\/strong\u003e We ship all orders within 5 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich couriers do you use?\u003c\/strong\u003e We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your return policy?\u003c\/strong\u003e We accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat approvals does this model have?\u003c\/strong\u003e The \u003cstrong\u003eXNX-AMSV-NHCB1\u003c\/strong\u003e holds ATEX and IEC certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this transmitter support HART?\u003c\/strong\u003e Yes, it has HART over 4-20mA and a local HART port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the sensor range?\u003c\/strong\u003e The MPD catalytic sensor measures 0-100% LEL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375196188930,"sku":"XNX-AMSV-NHCB1","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMSV-NHCB1.jpg?v=1787626966"},{"product_id":"xnx-amsv-nncb1-honeywell-universal-transmitter","title":"XNX-AMSV-NNCB1 Honeywell Universal Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-AMSV-NNCB1 Universal Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMSV-NNCB1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e XNX Universal Transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 4-20mA with HART® protocol for digital communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX and IEC certified for hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntry Type:\u003c\/strong\u003e Five M25 cable entries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e 316 stainless steel for maximum corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e mV version interfaces with milli-Volt sensors. Supports MPD, Sensepoint, Model 705 HT, and PPM sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptions:\u003c\/strong\u003e No additional options installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal HART:\u003c\/strong\u003e Not fitted on this configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Catalytic Bead (CB1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.8 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Depends on the connected mV sensor (catalytic bead).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Fast signal processing for real-time monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e High sensitivity for detecting low gas concentrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Excellent linearity across the sensor's full measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e High-resolution output for precise readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Wide range suitable for harsh industrial conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Withstands moisture, dust, and corrosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e Strong resistance to electromagnetic and radio frequency interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eXNX-AMSV-NNCB1\u003c\/strong\u003e securely in a suitable location.\u003c\/li\u003e\n\u003cli\u003eConnect your mV sensor (MPD, Sensepoint, or Model 705) to the interface.\u003c\/li\u003e\n\u003cli\u003eUse the five M25 entries for cable glands and conduit connections.\u003c\/li\u003e\n\u003cli\u003eWire the 4-20mA output to your control system or PLC.\u003c\/li\u003e\n\u003cli\u003eConfigure the transmitter settings using HART® communication if available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003eXNX-AMSV-NNCB1\u003c\/strong\u003e universal transmitter.\u003c\/li\u003e\n\u003cli\u003ePre-configured catalytic bead sensor interface (mV version).\u003c\/li\u003e\n\u003cli\u003eMounting bracket and hardware kit.\u003c\/li\u003e\n\u003cli\u003eFive M25 cable gland adapters.\u003c\/li\u003e\n\u003cli\u003eProduct documentation and quick start guide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this a new original unit?\u003c\/strong\u003e Yes, we supply brand new, genuine Honeywell transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this in stock?\u003c\/strong\u003e Yes, we stock the \u003cstrong\u003eXNX-AMSV-NNCB1\u003c\/strong\u003e for immediate orders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow quickly will you ship?\u003c\/strong\u003e We dispatch all orders within 5 working days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich couriers do you use?\u003c\/strong\u003e We ship via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is your return policy?\u003c\/strong\u003e We accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat approvals does this model have?\u003c\/strong\u003e The \u003cstrong\u003eXNX-AMSV-NNCB1\u003c\/strong\u003e carries ATEX and IEC certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat sensors work with this transmitter?\u003c\/strong\u003e It supports mV sensors like MPD, Sensepoint, Model 705 HT, and PPM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this include HART?\u003c\/strong\u003e No, this configuration has no local HART installed (N option).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the weight?\u003c\/strong\u003e The 316 stainless steel version weighs 6.8 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375204643074,"sku":"XNX-AMSV-NNCB1","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMSV-NNCB1.jpg?v=1787627297"},{"product_id":"xnx-amai-nhnnn-honeywell-universal-transmitter-atex-iec","title":"XNX-AMAI-NHNNN Honeywell Universal Transmitter ATEX IEC","description":"\u003ch2\u003e\u003cstrong\u003eXNX-AMAI-NHNNN Universal Transmitter by Honeywell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e XNX-AMAI-NHNNN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX\/IEC certified for hazardous areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEntry Type:\u003c\/strong\u003e M25 cable gland entry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Lightweight yet durable aluminium construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality:\u003c\/strong\u003e Interface for infrared products and 4-20mA inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal HART:\u003c\/strong\u003e Equipped with Local HART communication protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Surface mount via integral lugs; optional pipe kit for Ø100-150mm (Ø4”-6”) or ceiling bracket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Operating Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +65°C (-40°F to +149°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 0-99% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 90-110 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +75°C (-40°F to +167°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16 cm x 19.7 cm x 11.4 cm (6.1\" x 7.8\" x 4.5\")\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 Kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Mounting Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eXNX-AMAI-NHNNN\u003c\/strong\u003e directly to a flat surface using the built-in lugs.\u003c\/li\u003e\n\u003cli\u003eFor pipe mounting, order the optional kit designed for 100mm to 150mm pipes.\u003c\/li\u003e\n\u003cli\u003eYou can also use the optional ceiling mounting bracket for overhead installation.\u003c\/li\u003e\n\u003cli\u003eAlways ensure the M25 entry aligns with your cable gland for a secure seal.\u003c\/li\u003e\n\u003cli\u003eVerify the ambient conditions stay within the specified temperature and pressure ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne Honeywell XNX-AMAI-NHNNN Universal Transmitter unit\u003c\/li\u003e\n\u003cli\u003eIntegral mounting lugs (pre-installed)\u003c\/li\u003e\n\u003cli\u003eUser manual and quick start guide\u003c\/li\u003e\n\u003cli\u003eTerminal blocks and sealing accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Returns\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e We ship via FedEx, UPS, or DHL within 5 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e We accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock:\u003c\/strong\u003e All units are brand new and in stock for immediate dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the XNX-AMAI-NHNNN a new unit?\u003c\/strong\u003e Yes, we supply only brand new, original Honeywell transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have this model in stock?\u003c\/strong\u003e Yes, we keep the XNX-AMAI-NHNNN in stock for fast delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the typical lead time?\u003c\/strong\u003e We ship all orders within 5 business days via DHL, UPS, or FedEx.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e It operates from -40°C to +65°C (-40°F to +149°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I mount it on a pipe?\u003c\/strong\u003e Yes, use the optional pipe mounting kit for Ø100-150mm pipes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it support HART communication?\u003c\/strong\u003e Yes, this model includes Local HART capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat approvals does it hold?\u003c\/strong\u003e It carries ATEX and IEC certifications for safe use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the weight of the unit?\u003c\/strong\u003e The transmitter weighs 5 Kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375207723266,"sku":"XNX-AMAI-NHNNN","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMAI-NHNNN.jpg?v=1787627508"}],"url":"https:\/\/www.nex-auto.com\/collections\/honeywell-others.oembed?page=4","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}