MTL3021 MTL Instruments Solenoid/Alarm Driver
MTL3021 Hazardous Area Control Interface: Safe Control for Dangerous Environments The MTL3021 control interface from MTL Instruments provides reliable operation in hazardous locations. This robust device controls Zone 0 and IIC area equipment from safe-area control signals. It delivers dependable performance for critical industrial... -
Vendor: More Brands
MTL3045 Isolating Driver - Eaton MTL
MTL3045 Signal Isolator for Hazardous Areas The MTL3045 provides precision isolation for 4-20mA/0-20mA control signals to hazardous-area devices. With 16V output capability and minimal voltage drop, it's ideal for driving I/P converters, actuators, and other loads up to 800Ω. Key Features Maintains ±20μA accuracy... -
Vendor: More Brands
MTL3073 Transmitter MTL Instruments
MTL3073 Temperature Transmitter for Hazardous Areas Core Functionality • Converts thermocouple/RTD signals to 4-20mA • Software-configurable for 8 thermocouple types and RTDs • Integral cold-junction compensation • Zone 0, IIC, T4 certified Technical Specifications Input Types: J,K,T,E,R,S,B,N thermocouples | 2/3/4-wire RTDs Input Range: -75... -
Vendor: More Brands
MTL4045C MTL - Temperature Transmitter
Product Introduction The MTL4045C safely repeats 4-20mA signals in hazardous areas. This isolator drives I/P converters or loads up to 800Ω with 16V output capability. Its floating input/output circuits ensure reliable operation in Zone 0/Div.1 locations. Key Features Single-channel 4-20mA signal repeater for hazardous... -
Vendor: More Brands
MTL4541B MTL Instrument - Repeater Power Supply
Hazardous Area Signal Isolator with HART Support The MTL4541B safely powers 2/3-wire transmitters in explosive areas while repeating 4-20mA signals to safe zones. This intrinsically safe barrier maintains HART communication for smart instrumentation. Core Capabilities Powers Zone 0/Div.1 transmitters with 16.5V@20mA Bi-directional HART signal... -
Vendor: More Brands
MTL4544 | Dual-Channel HART Transmitter Isolator
MTL4544 Dual-Channel HART Transmitter Isolator Dual-Channel Signal Conditioning for Hazardous Areas The MTL4544 provides two independent isolation channels for 2-wire or 3-wire 4-20mA/HART transmitters in Zone 0/Div. 1 hazardous locations. This intrinsically safe solution delivers 16.5V transmitter power while maintaining full HART communication capability.... -
Vendor: More Brands
MTL4544S MTL Instrument | Repeater Power Supply
Dual-Channel Current Sink for Hazardous Areas The MTL4544S provides two independent current sink channels for 4-wire transmitters in explosive environments. This intrinsically safe interface supports 24V sources while maintaining Zone 0 safety standards. Key Advantages Dual-channel design for multi-point monitoring 600Ω current sink capacity... -
Vendor: More Brands
MTL5021 Safe-to-Hazardous Area Control Interface
MTL5021 Safe-to-Hazardous Area Control Interface Explosion Protection Zone 0, IIC, T4-T6 Certified - For gas group IIC environments Div. 1, Group A Rated - Meets NFPA 70 (NEC) requirements 250V Isolation Voltage - Full circuit separation Power Specifications Output Range: 12.85V (min) to 24V... -
Vendor: More Brands
MTL5022 | Eaton MTL Solenoid/Alarm Driver
MTL5022 Hazardous Area Control Interface Core Technical Specifications Output voltage range: 12.9V to 24V Max output current: 60mA Input voltage: 20V–35V DC Load resistance: Up to 133Ω Power dissipation: 1.5W (24V), 2.1W (35V) Isolation: 250V rms/dc (Um) Response time: <100ms Industrial Uses Safe control... -
Vendor: More Brands
MTL5046 Isolating Driver | MTL Instruments
MTL5046 Isolating Driver Hazardous Area Signal Conditioner with 4-20mA Isolation Key Feature: Safe signal transmission between Zone 0 hazardous areas and safe areas with 500Hz-10kHz bandwidth Technical Specifications Manufacturer MTL Instruments Channels 1 channel isolated Input Range 4-20mA (1-24mA overrange) Bandwidth 500Hz to 10kHz... -
Vendor: More Brands
MTL5049 MTL Instruments - Isolating Driver
MTL5049 Dual-Channel 4-20mA Isolator for Hazardous Areas Core Specifications Channels: 2 isolated 4-20mA Input Range: 0-24mA (4-20mA nominal) Output Load: ≤550Ω (11V@20mA) Accuracy: ±20μA @20°C Response Time: 250μs to 90% value Isolation: 28V, 300Ω, 93mA (Um=250V) Wiring Configuration Terminal Function 1, 2 Channel 1... -
Vendor: Honeywell
MTL5074 - MTL Smart Temperature Transmitter
MTL5074 Smart Temperature Transmitter Hazardous Area to 4-20mA Converter Key Benefit: Converts thermocouple/RTD signals to isolated 4-20mA with software-configurable linearization for Zone 0/Div1 areas Core Specifications Input Types J/K/T/E/R/S/B/N thermocouples2/3/4-wire RTDs (100Ω @0°C) Accuracy ±0.05% or ±15μV (TC)±80mΩ (RTD)±11μA (output) Temperature Range -75mV to... -
Vendor: More Brands
MTL5511 Switch/Proximity Detector Interface
MTL5511 Switch/Proximity Detector Interface Overview The MTL5511 safely connects hazardous-area sensors to control systems. This interface module works with NAMUR-compliant devices in explosive environments. It provides reliable signal conversion between Zone 0 and safe areas. Key Features Approved for use in hazardous locations Compact... -
Vendor: More Brands
MTL5514D Safe Industrial Switching for Hazardous Areas
MTL5514D - Safe Industrial Switching for Hazardous Areas Reliable Sensor Interface The MTL5514D connects hazardous area sensors to control systems. It works with switches and proximity detectors in explosive environments. Two relay outputs provide safe area control. Key Technical Specs Input channels: 1 (NAMUR... -
Vendor: More Brands
MTL5521 Solenoid/Alarm Driver | MTL Instruments
MTL5521 Solenoid/Alarm Driver Hazardous Area Control Solution Galvanic barrier for safe operation of solenoids and alarms in explosive environments. ATEX certified for hazardous locations. Technical Specifications • Power Supply: 20-35V DC • Safety Output: 10.5V max, 108mA max • Signal Type: Loop powered digital... -
Vendor: More Brands
MTL5541 Repeater Power Supply for Hazardous Areas
MTL5541 Repeater Power Supply for Hazardous Areas Essential Protection The MTL5541 safely transfers signals from Zone 0 hazardous areas. It provides clean power to transmitters while maintaining signal integrity. Precision Performance Transfer accuracy: ±15μA at 20°C Temperature stability: <0.8μA/°C drift Fast response: 50μs to... -
Vendor: More Brands
MTL5541S Repeater Power Supply Isolator
MTL5541S Repeater Power Supply Isolator Core Functionality DIN-rail mounted isolator for precise signal transfer in hazardous areas. Provides safe power to transmitters with minimal signal distortion. Key Specifications • Input/Output: 1 channel analog (0-24mA) • Ripple: <50µA peak-to-peak • Accuracy: ±15µA at 20°C •... -
Vendor: More Brands
MTL5573 MTL - Temperature Transmitter
MTL5573 Temperature Transmitter for Hazardous Areas Core Specifications Input Channels 1 channel (Zone 0, IIC, Div.1 Groups A-D) Sensor Types Thermocouples & RTDs Output Signal 4-20mA into 600Ω max Technical Parameters RTD Excitation 200μA nominal CJC Accuracy ≤1.0°C error Noise Rejection 120dB CMRR /... -
Vendor: More Brands
MTL831B MTL Instruments - Multiplexer Transmitter
MTL831B Multiplexer Transmitter for Hazardous Zone 0 Monitoring Key Features 16-channel THC/mV (±60mV) or 15-channel RTD (2/3/4-wire) inputs Dual redundant Modbus® data highways (loop-powered) Mixed sensor support: Thermocouples + RTDs on one unit Intrinsically safe for Zone 0, IIC, T4 (Group A-D hazardous areas)... -
Vendor: Siemens
Multi-Feature Drive Converter 6SE7018-0EP50-Z
Siemens 6SE7018-0EP50-Z Multi-Feature Drive Converter Advanced Package Includes: PROFIBUS module + Resolver transducer + Standard tech functions - Ready for immediate integration Key Advantages 🔄 Complete motion control solution in one unit 📶 PROFIBUS CBP2 communication pre-installed 📏 Resolver transducer for precise positioning ⚙️...