{"product_id":"ge-fanuc-ic660tpm100-genius-i-o-terminal-assembly","title":"GE Fanuc IC660TPM100 | Genius I\/O Terminal Assembly","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC660TPM100 Terminal Assembly for Power Monitoring\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC660TPM100\u003c\/strong\u003e is a terminal assembly base unit designed for the IC660BPM100 power monitoring block in GE Fanuc's GENIUS I\/O system. \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEssential Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Unit Function:\u003c\/strong\u003e Terminal assembly for IC660BPM100 power monitoring block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Storage:\u003c\/strong\u003e Onboard EEPROM retains configuration settings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Compatibility:\u003c\/strong\u003e Accepts both solid and stranded wires (\u003cspan style=\"color: #c0392b;\"\u003e10-14 AWG\u003c\/span\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Count:\u003c\/strong\u003e \u003cspan style=\"color: #16a085;\"\u003e32 terminals\u003c\/span\u003e including serial communication and shield connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Indicator:\u003c\/strong\u003e LED for proper installation verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Types:\u003c\/strong\u003e Screw terminals with captive pressure plates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Construction:\u003c\/strong\u003e High-temperature thermoplastic with metal inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eIC660TPM100\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc (Emerson Automation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Input Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e115\/230V AC\u003c\/span\u003e or \u003cspan style=\"color: #c0392b;\"\u003e125V DC\u003c\/span\u003e compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew Terminals Required:\u003c\/strong\u003e \u003cspan style=\"color: #16a085;\"\u003e12 minimum\u003c\/span\u003e for proper installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source Support:\u003c\/strong\u003e Up to \u003cspan style=\"color: #16a085;\"\u003e5 independent power sources\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 0.5-0.6 Nm (4.4-5.3 lb-in) recommended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e 2500V AC for 60 seconds terminal-to-base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e \u0026gt; 100 MΩ at 500V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Weight:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e2 lbs (0.9 kg)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #16a085;\"\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Connection Types:\u003c\/strong\u003e Bare wire, spade lugs, or ring lugs compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Material:\u003c\/strong\u003e Tin-plated copper alloy for reliable connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e UL94V-0 rated thermoplastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method:\u003c\/strong\u003e Panel mounting with 4 mounting holes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approximately 150 × 100 × 50 mm (5.9 × 3.9 × 2.0 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1:\u003c\/strong\u003e Drill 4 mounting holes according to datasheet specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2:\u003c\/strong\u003e Separate electronics assembly from terminal base if pre-assembled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 3:\u003c\/strong\u003e Align terminal assembly notches with mounting surface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 4:\u003c\/strong\u003e Secure with #12 screws and star washers for proper grounding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 5:\u003c\/strong\u003e Use spaghetti tubing for shield wire terminations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 6:\u003c\/strong\u003e Verify all connections before applying power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 7:\u003c\/strong\u003e Check diagnostic LED for proper installation confirmation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Time:\u003c\/strong\u003e Typically 15-30 minutes for experienced technicians\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Compatibility:\u003c\/strong\u003e IC660BPM100 power monitoring block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication System:\u003c\/strong\u003e GENIUS I\/O communication bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Systems:\u003c\/strong\u003e Wye (4-wire) and Delta (3-wire) configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Systems:\u003c\/strong\u003e Single-phase and three-phase power systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Transformer Types:\u003c\/strong\u003e Compatible with standard 5A and 1A CTs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Systems:\u003c\/strong\u003e GE Series 90-30\/90-70 PLCs with GENIUS interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRMS Values:\u003c\/strong\u003e True RMS current and voltage measurements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Parameters:\u003c\/strong\u003e Real power, reactive power, apparent power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Factor:\u003c\/strong\u003e Individual phase and total power factor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Frequency:\u003c\/strong\u003e 45-65 Hz measurement range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Measurements:\u003c\/strong\u003e Watt-hours and VAR-hours accumulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic Analysis:\u003c\/strong\u003e Up to 31st harmonic content analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWaveform Compatibility:\u003c\/strong\u003e Works accurately with distorted waveforms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Class:\u003c\/strong\u003e 0.5% of reading typical for voltage and current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 1-10 cycles configurable measurement intervals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Warning:\u003c\/strong\u003e Never remove terminal assembly during system operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Burden:\u003c\/strong\u003e \u003cspan style=\"color: #16a085;\"\u003e\u0026lt; 0.1 VA\u003c\/span\u003e typical burden on current transformers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e Electronics assembly is hot-swappable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Advantage:\u003c\/strong\u003e Field wiring remains intact during electronics maintenance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Proper grounding essential for accurate measurements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 2500V isolation between current and voltage circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certifications:\u003c\/strong\u003e UL 508, CSA 22.2 No. 142, CE marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e IC660TPM100 terminal assembly only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Availability:\u003c\/strong\u003e Typically ships same day when in stock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e Global options via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Installation guide and wiring diagrams included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protective packaging to prevent damage during transit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Time:\u003c\/strong\u003e Usually 1-3 business days for standard orders\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Standard manufacturer warranty applies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the purpose of the onboard EEPROM?\u003c\/strong\u003e Stores configuration settings so wiring remains intact during electronics replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this terminal base be used alone?\u003c\/strong\u003e No, it requires the IC660BPM100 electronics assembly for complete functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat wire sizes are supported?\u003c\/strong\u003e 10-14 AWG (2.5-6.0 mm²) solid or stranded copper wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor technical documentation and installation support for the \u003cstrong\u003eIC660TPM100\u003c\/strong\u003e terminal assembly, contact our engineering team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information:\u003c\/strong\u003e\u003cbr\u003eEmail: \u003cstrong\u003e\u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003ePhone\/WhatsApp: \u003cstrong\u003e\u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner:\u003c\/strong\u003e \u003cstrong\u003e\u003ca href=\"https:\/\/www.autonexcontrol.com\/\" target=\"_blank\"\u003eAutoNex Controls Limited\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e© 2025 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003cstrong\u003e\u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":46613756018946,"sku":"IC660TPM100","price":288.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IC660TPM100.jpg?v=1765782520","url":"https:\/\/www.nex-auto.com\/el\/products\/ge-fanuc-ic660tpm100-genius-i-o-terminal-assembly","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}