{"product_id":"schneider-tsxasy800-precision-control-output-module","title":"Schneider TSXASY800 | Precision Control Output Module","description":"\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #e74c3c;\"\u003eSchneider Electric TSXASY800\u003c\/span\u003e\u003c\/strong\u003e is an 8-channel analog output module for the Modicon TSX Premium platform. It provides precise command signals to control valves, drives, and other process actuators. This module is essential for closed-loop control and automation tasks requiring variable outputs.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Schneider Electric \u003cstrong\u003eTSXASY800\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 8-Channel Analog Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 8 configurable voltage or current outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Types:\u003c\/strong\u003e Voltage (±10V) or Current (0-20 mA, 4-20 mA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e High 13-bit resolution for precise control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.14% of full scale for voltage at 25°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePerformance \u0026amp; Electrical Data\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion Time:\u003c\/strong\u003e 5 ms update rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Requirements:\u003c\/strong\u003e Min. 500 Ω for current outputs; \u0026gt;1000 Ω for voltage outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtections:\u003c\/strong\u003e Integrated short-circuit and overload protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1000 Vrms between channels\/bus and channels\/ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Requires 24V DC (300 mA) and 5V DC (200 mA) from the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e 1 SUB-D 25-pin connector for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental Data\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -25°C to 70°C (-13°F to 158°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 10% to 95% RH, non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.01 lbs (0.46 kg).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20 for enclosure installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e One (1) TSXASY800 analog output module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Dimensions:\u003c\/strong\u003e 10.2\" L x 7.09\" W x 2.2\" H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Weight:\u003c\/strong\u003e 16.4 oz (465 g).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is this module used to control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt controls devices that require an analog signal, such as variable frequency drive speed references, proportional valve positions, actuator setpoints, or chart recorder inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 0-20 mA and 4-20 mA output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e4-20 mA is the industry standard where 4 mA represents the \"live zero\" or minimum scale, allowing the system to detect a broken wire (0 mA). 0-20 mA is a simpler, less common range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is load impedance important?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output must see a minimum load to regulate the current correctly. For a 4-20 mA output, the total loop resistance (wire + device) must be less than 600 ohms for the \u003cstrong\u003eTSXASY800\u003c\/strong\u003e to operate properly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow fast can it update the output signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module updates all outputs within a 5 ms cycle time, which is sufficiently fast for most process control applications like flow, pressure, or temperature regulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix voltage and current outputs on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, each of the 8 channels can be independently configured in the PLC software for either voltage or current output, providing great flexibility.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":47327970230530,"sku":"TSXASY800","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/TSXASY800.jpg?v=1770105179","url":"https:\/\/www.nex-auto.com\/fr\/products\/schneider-tsxasy800-precision-control-output-module","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}