{"product_id":"ge-fanuc-ic660tsa100-terminal-assembly-analog-i-o-base","title":"GE Fanuc IC660TSA100 Terminal Assembly | Analog I\/O Base","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC660TSA100 Analog I\/O Terminal Assembly\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC660TSA100\u003c\/strong\u003e is a versatile analog I\/O terminal assembly featuring 4 analog inputs and 2 analog outputs with dual power supply options. \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Configuration:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e4 analog inputs\u003c\/span\u003e + \u003cspan style=\"color: #c0392b;\"\u003e2 analog outputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Options:\u003c\/strong\u003e Dual voltage - \u003cspan style=\"color: #16a085;\"\u003e115V AC\u003c\/span\u003e or \u003cspan style=\"color: #16a085;\"\u003e24-48V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Design:\u003c\/strong\u003e Field-ready construction for harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Labeling:\u003c\/strong\u003e Clear front-facing labels for easy identification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Screw terminal connections for secure wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e \"I\/O Enabled\" and \"Unit OK\" LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Layout:\u003c\/strong\u003e Logical grouping of inputs, outputs, and power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eIC660TSA100\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc (Emerson Automation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e98-132V AC nominal\u003c\/span\u003e or 24-48V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e \u003cspan style=\"color: #16a085;\"\u003e±0.2% full scale\u003c\/span\u003e at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Range Support:\u003c\/strong\u003e 5 voltage\/current options available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e1500V block-to-block\u003c\/span\u003e isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #16a085;\"\u003e6W maximum\u003c\/span\u003e typical operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3-6W depending on configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12-bit for both inputs and outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e224.4 × 33.4 × 39.1 mm (8.83 × 1.31 × 1.54 in)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Weight:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e4 lbs (1.8 kg)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Options:\u003c\/strong\u003e Panel, wall, or DIN rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Type:\u003c\/strong\u003e Standard 35 mm DIN rail (EN 60715)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance Requirement:\u003c\/strong\u003e 2\" minimum clearance for cooling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e UL94V-0 rated thermoplastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Removable screw terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e Accepts 18-14 AWG (0.75-2.5 mm²) wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Range Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Ranges:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e0-5V DC\u003c\/li\u003e\n\u003cli\u003e0-10V DC\u003c\/li\u003e\n\u003cli\u003e-10 to +10V DC\u003c\/li\u003e\n\u003cli\u003e-5 to +5V DC\u003c\/li\u003e\n\u003cli\u003e1-5V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e4-20mA with 250Ω input impedance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt; 1 MΩ for voltage inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Drive:\u003c\/strong\u003e Up to 20mA current source capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e \u0026gt; 120 dB at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e Configurable 10-100 ms scan times\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #16a085;\"\u003e0-60°C (32-140°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 5-10Hz @ 0.2\" displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 15G for 11 ms duration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Use:\u003c\/strong\u003e Indoor use only - not waterproof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Requirement:\u003c\/strong\u003e Requires 2\" clearance for natural convection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e Degree 2 per IEC 61131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Components\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Assembly:\u003c\/strong\u003e IC660TSA100 (this unit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog I\/O Block:\u003c\/strong\u003e IC660BBA100 complete assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronics Assembly:\u003c\/strong\u003e IC660EBA100 electronic components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication System:\u003c\/strong\u003e GENIUS I\/O network compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Integration:\u003c\/strong\u003e GE Series 90-30\/90-70 PLC systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Tools:\u003c\/strong\u003e GE Fanuc configuration software required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Power down system before wiring connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Use proper grounding (12 AWG minimum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Circulation:\u003c\/strong\u003e Maintain adequate air circulation around unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicator Verification:\u003c\/strong\u003e Check \"I\/O Enabled\" and \"Unit OK\" LEDs after installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI Protection:\u003c\/strong\u003e Avoid installation near RF interference sources\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Routing:\u003c\/strong\u003e Separate analog signals from power wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 0.5-0.6 Nm (4.4-5.3 lb-in) recommended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLabeling:\u003c\/strong\u003e Label all wires for future maintenance reference\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Monitoring:\u003c\/strong\u003e Temperature, pressure, flow, level monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Control:\u003c\/strong\u003e Small machine automation and control systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sensing:\u003c\/strong\u003e Humidity, pH, conductivity measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Equipment:\u003c\/strong\u003e Test bench instrumentation and measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Expansion:\u003c\/strong\u003e Expansion of PLC analog I\/O capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Management:\u003c\/strong\u003e Power monitoring and consumption tracking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Control:\u003c\/strong\u003e Production quality monitoring and control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e Withstands up to 50V continuous on inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection:\u003c\/strong\u003e Current limiting on output circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection:\u003c\/strong\u003e Protected against incorrect connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e ±8 kV contact discharge capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1500V between analog circuits and power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certifications:\u003c\/strong\u003e UL 508, CSA 22.2 No. 142, CE marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e IC660TSA100 terminal assembly with hardware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Hardware:\u003c\/strong\u003e DIN rail clips and mounting screws included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Installation guide and wiring diagrams\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e Available via FedEx, UPS, DHL with tracking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Time:\u003c\/strong\u003e Typically ships within 3-7 business days\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical Support:\u003c\/strong\u003e Available for installation questions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Standard manufacturer warranty applies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat power supplies are compatible?\u003c\/strong\u003e 115V AC (98-132V) or 24-48V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan inputs and outputs use different signal types?\u003c\/strong\u003e Yes, each channel is independently configurable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this a complete analog module?\u003c\/strong\u003e No, this is the terminal base only; requires electronics assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor analog system integration and technical support for the \u003cstrong\u003eIC660TSA100\u003c\/strong\u003e terminal assembly, contact our engineering team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Information:\u003c\/strong\u003e\u003cbr\u003eEmail: \u003cstrong\u003e\u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003ePhone\/WhatsApp: \u003cstrong\u003e\u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePartner:\u003c\/strong\u003e \u003cstrong\u003e\u003ca href=\"https:\/\/www.autonexcontrol.com\/\" target=\"_blank\"\u003eAutoNex Controls Limited\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e© 2025 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003cstrong\u003e\u003ca href=\"https:\/\/www.nex-auto.com\/\" target=\"_blank\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":46614156935426,"sku":"IC660TSA100","price":278.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IC660TSA100.jpg?v=1765783277","url":"https:\/\/www.nex-auto.com\/id\/products\/ge-fanuc-ic660tsa100-terminal-assembly-analog-i-o-base","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}