{"product_id":"epm-s501-lenze-4-channel-analog-output-module","title":"EPM-S501 Lenze 4-Channel Analog Output Module","description":"\u003ch2\u003eLenze EPM-S501 Analog Output Module: Precise Signal Control\u003c\/h2\u003e\n\u003cp\u003eConnect your control system to the real world. The \u003cstrong\u003eLenze EPM-S501\u003c\/strong\u003e is a digital I\/O module with four precise analog outputs. It converts bus commands into smooth 0-10V signals to control devices like valves or drives.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-Channel Output:\u003c\/strong\u003e Controls up to four devices independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision:\u003c\/strong\u003e 12-bit resolution for accurate signal control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Diagnostics:\u003c\/strong\u003e Clear LED status lights for quick troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple Power:\u003c\/strong\u003e Uses standard 24V DC supply voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Integration:\u003c\/strong\u003e Quick 2 ms conversion time for all channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick Shipping:\u003c\/strong\u003e Delivered fast via FedEx, UPS, or DHL with a 12-month warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #3498db;\"\u003eModel:\u003c\/strong\u003e Lenze EPM-S501 I\/O Module\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eType:\u003c\/strong\u003e 4-Channel Analog Output Module\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eOutput Signal:\u003c\/strong\u003e 0 to +10 VDC\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eResolution:\u003c\/strong\u003e 12-bit\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eBasic Error Limit:\u003c\/strong\u003e ±0.2%\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eSupply Voltage:\u003c\/strong\u003e 24 V DC\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003ePower Loss:\u003c\/strong\u003e 1.2 W\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eCurrent Consumption:\u003c\/strong\u003e 80 mA (bus) + 35 mA (load voltage)\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eConversion Time:\u003c\/strong\u003e 2 ms (all 4 channels)\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eMax Cable Length:\u003c\/strong\u003e 200 m (shielded)\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eMin Load Impedance:\u003c\/strong\u003e 5 kΩ\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eShort-Circuit Protection:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong style=\"color: #3498db;\"\u003eIsolation:\u003c\/strong\u003e 75 V DC \/ 60 V AC\u003c\/p\u003e\n\u003ch3\u003eLED Status Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRUN (Green):\u003c\/strong\u003e On = Module ready. Off = Power error.\u003cbr\u003e\u003cstrong\u003eMF (Red):\u003c\/strong\u003e On = Module fault. Blinking = Configuration error.\u003cbr\u003e\u003cstrong\u003eAO1-AO4 (Red):\u003c\/strong\u003e Per-channel fault (overload, short-circuit, parameter error).\u003c\/p\u003e\n\u003ch3\u003eFAQs for System Integrators\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat devices can I control with this module?\u003c\/strong\u003e\u003cbr\u003eYou can control frequency drives, servo controllers, proportional valves, or any device that accepts a 0-10V control signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle wiring for noise-sensitive applications?\u003c\/strong\u003e\u003cbr\u003eAlways use shielded cables and ground the shield at one end. Keep signal cables away from power lines to prevent interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if my PLC communication fails?\u003c\/strong\u003e\u003cbr\u003eThe module can be configured to output a predefined substitute value (like 0V or 10V) for safety during communication loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use one output to control multiple devices?\u003c\/strong\u003e\u003cbr\u003eIt’s not recommended. The output is designed for a minimum 5 kΩ load. Connecting multiple devices in parallel may overload it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is my channel error LED lit?\u003c\/strong\u003e\u003cbr\u003eCheck for a short circuit on the output wires or verify that the connected device's impedance is not too low (below 5 kΩ).\u003c\/p\u003e\n\u003ch3\u003eWarranty \u0026amp; Delivery\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eLenze EPM-S501\u003c\/strong\u003e module is backed by a \u003cstrong style=\"color: #e74c3c;\"\u003e12-month warranty\u003c\/strong\u003e. Orders ship quickly and securely via FedEx, UPS, or DHL.\u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":47164283486466,"sku":"EPM-S501","price":211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/EPM-S501.jpg?v=1766629787","url":"https:\/\/www.nex-auto.com\/ms\/products\/epm-s501-lenze-4-channel-analog-output-module","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}