About the Product

Bently Nevada 2300/25-00 | Monitor with SPA Outputs (No Approvals)

Manufacturer: Bently Nevada | Part Number: 2300/25-00 | Type: Monitor with SPA Outputs | Approval: None (00) | Made in: U.S.A.

Key Specifications

  • Power Input: 18 to 36 Vdc, maximum 7.5 Watts
  • Operating Temperature: -30°C to +65°C (-22°F to +149°F)
  • Storage Temperature: -40°C to +85°C (-40°F to +185°F)
  • Humidity: Up to 95% non-condensing
  • Vibration Limitation: 3g
  • Weight: 1.03 kg (2.26 lbs)
  • Mounting: Panel mount or DIN rail (adapter included)

Physical Dimensions

  • Width: 127 mm (5 inches)
  • Depth: 127 mm (5 inches)
  • Height: 76.2 mm (3 inches)
  • Compact design: Fits in standard industrial enclosures

Input Channels

  • ICP Accelerometers: 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV/g scale factor, 2 to 80 g peak full scale
  • Velocity: 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV/in/s scale factor, 0 to 50 in/s peak full scale
  • Radial Vibration: 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV/mil scale factor, 0 to 160 mil peak-peak full scale
  • Thrust Channel: 5 to 1000 mV/mil scale factor range
  • Process Variable Channel: Supports most units with default on temperature

Speed/Keyphasor Input

  • Keyphasor transducers: Support multiple events per revolution
  • Speed input: Up to 20 kHz
  • Threshold voltage resolution: 0.1 Vdc
  • RPM range: 1 to 120,000 (proximity), 1 to 60,000 (proximity switch), 200 to 120,000 (magnetic pickup)

Proximity Transducer Interface

  • Supply Voltage: -22.8 to -25.2 Vdc
  • Maximum Rated Current: 15 mA
  • Short Circuit Current: 15.1 to 23.6 mA
  • Accuracy: ±1% of full scale range
  • Input Impedance (3-wire Voltage Mode): 10 kΩ

Measurement Accuracy

  • Temperature Channel: ±1% of full scale range
  • Proximity Transducer: ±1% of full scale range
  • Independent 24-bit ADCs: On all input channels
  • SPA Output Accuracy: High/Low AC ±1% of full-scale at 100 Hz, DC GAP ±0.5V

Outputs

  • Buffered Outputs (BNC): 2 vibration outputs, 1 speed output
  • Relays: Two dry-contact outputs, epoxy sealed, single pole double throw
  • Relay Contact Life: 100,000 cycles at 5A, 250 Vac; 200,000 at 1A, 24 Vdc
  • SPA Output (2300/25): High AC 8 Vpp, Low AC 1.6 Vpp, DC GAP 0 to -20 Vdc
  • SPA Frequency Response: 10 Hz to 3000 Hz ±5%

Relay Specifications (Non-Hazardous Area)

  • Type: Single pole, double throw, epoxy sealed
  • Maximum switched contact voltage: 250 Vac / 250 Vdc
  • Maximum breaking contact current: 6A at 250 Vac / 6A at 24 Vdc
  • Maximum switched power: 1500VA AC / 150 Watts DC

Communications

  • Ethernet: 10Base-T and 100Base-TX, conforms to IEEE802.3
  • Connector: RJ-45 for 10Base-T/100Base-TX
  • Maximum Cable Length: 100 meters (328 feet)

Data Storage

  • Network disruption: Stores up to 5 alarm data captures
  • Requires: System 1 Evolution 21.1 or newer, Firmware 3.2 or newer
  • Trend Intervals: Pre-event 10 minutes at 1 second, 20 seconds at 100 milliseconds
  • Spectrum/Waveform: Pre-event 2.5 minutes at 10 seconds

Battery Life (Real Time Clock)

  • Powered: 38 years at 50°C (122°F)
  • Un-powered: 12 years at 50°C (122°F)

Front Panel LEDs

  • OK: Monitor operating properly
  • Protection Fault: Hardware fault impacting alarm determination
  • User Inhibit: Alarms/relays intentionally inhibited
  • Bypass: User initiated bypass action
  • Relay Status: Relays activated
  • TX/RX: Ethernet status and remote communication
  • SPEED/AUX Channel Status: Valid speed signal or operating correctly
  • Alert LED: Any channel in alert state
  • Danger LED: Any channel in danger state

LCD Display

  • View machine speed readings
  • View vibration measurement values
  • View setpoints and configuration information

Contact Inputs

  • 3 contact capabilities with input terminals for:
  • Configuration lock
  • Latched alarm/relay reset function
  • Monitor bypass (activate 0 to 10 kΩ, de-activate 150 kΩ to infinite)

Button Inputs

  • External button to reset latched alarm and relay
  • One buried button provides 3 functions:
    • Display monitor information
    • LCD contrast adjustment
    • Reset settings to default

Package Contents

  • 2300/25-00 monitor with SPA outputs
  • DIN rail mount assembly (adapter included)
  • Monitor configuration software
  • Installation manual

Shipping Information

  • Weight: 1.5 kg (3.3 lb) packaged
  • Packaging: Factory sealed box
  • Carriers: FedEx, UPS, DHL (2-5 business days)

Frequently Asked Questions

  • Q: What is the difference between 2300/25-00 and 2300/25-02?
    A: The 2300/25-00 has no hazardous area approvals (option 00). The 2300/25-02 has multiple explosive atmosphere certifications (ATEX/IECEx/CSA). Choose -00 for safe area installations only.
  • Q: What is the SPA output?
    A: SPA (Signal Processing Assembly) output provides High AC (8 Vpp), Low AC (1.6 Vpp), and DC GAP (0 to -20 Vdc) signals with frequency response of 10 Hz to 3000 Hz ±5% for external analysis.
  • Q: How many channels does this monitor support?
    A: The 2300/25-00 supports multiple channel types including ICP accelerometers, velocity, radial vibration, thrust, process variable, temperature, speed/Keyphasor, proximity switch, and magnetic pickup inputs.
  • Q: What is the accuracy of the measurements?
    A: The monitor features independent 24-bit ADCs on all input channels with ±1% of full scale range accuracy for most measurements. DC GAP accuracy is ±0.5V.
  • Q: Does the monitor store data during network outages?
    A: Yes. The 2300 can store up to 5 alarm data captures during network disruption between the 2300 and System 1. Requires System 1 Evolution 21.1 or newer and Firmware 3.2 or newer.
  • Quick Quotes: Receive pricing and availability fast from our dedicated customer service team.
  • Delivery: Expedited, freight, and international shipping available worldwide.
  • Warranty: NexAuto offers a 12-month warranty on all parts purchased from us, in addition to any manufacturer coverage.
  • Returns: 30-day return policy for defective or mismatched parts, ensuring peace of mind.
  • Payment: Flexible options including major credit cards, PayPal, and bank transfers.
  • Custom Calibration: Provide your specifications, and we’ll handle the rest with precision.
View Product Details