{"product_id":"330102-00-10-10-01-05-3300-xl-8mm-armored-probe-bently-nevada","title":"330102-00-10-10-01-05 3300 XL 8mm Armored Probe Bently Nevada","description":"\u003ch2\u003eFlush Mount Armored 8mm Probe with Full Hazardous Approvals\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330102-00-10-10-01-05\u003c\/strong\u003e belongs to the trusted 3300 XL series. We design this compact armored 8mm probe for accurate displacement and vibration measurements in hazardous areas where flush mounting is required. The \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003ezero unthreaded tip (0 inch)\u003c\/span\u003e allows threads to start immediately at the probe face. \u003c\/p\u003e\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada. \u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e330102-00-10-10-01-05\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cstrong\u003e3300 XL 8 mm Proximity Probe\u003c\/strong\u003e with 3\/8-24 UNF thread, \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003ewith armor\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003eZero unthreaded tip (flush mount)\u003c\/span\u003e, 1.0 inch (25.4mm) overall case length, and 1.0 meter (3.3 feet) total length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Miniature coaxial \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003eClickLoc connector with connector protector\u003c\/span\u003e and standard cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Probe tip uses \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003ePolyphenylene sulfide (PPS)\u003c\/span\u003e. Probe case uses AISI 303 or 304 stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Resistance:\u003c\/strong\u003e Nominal probe resistance measures \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003e7.59 ± 0.50 Ω\u003c\/span\u003e for 1.0m length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Probe weighs 323 g\/m (11.4 oz\/ft).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003eCSA, ATEX, IECEx\u003c\/span\u003e for hazardous area installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental and Operating Ranges\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature (Standard):\u003c\/strong\u003e Operates and stores from \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003e-52°C to +177°C (-62°F to +350°F)\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature (Extended):\u003c\/strong\u003e Probe tip reaches \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003e-52°C to +218°C (-62°F to +425°F)\u003c\/span\u003e. Cable and connector handle up to +260°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e Average Scale Factor changes less than 3% after 56 days in 93% humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Seal:\u003c\/strong\u003e Uses Viton® O-ring to seal differential pressure between tip and case.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmor Protection:\u003c\/strong\u003e Cable armor resists mechanical damage in high-wear installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protector:\u003c\/strong\u003e Added protection keeps ClickLoc connection secure in harsh conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e Certified for Class I, Zone 0 and Zone 2 environments with appropriate barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and Mounting Guide\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Maximum thread engagement length is \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003e0.563 inch (14.3 mm)\u003c\/span\u003e for 3\/8-24 UNF case thread.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque (Forward Mount):\u003c\/strong\u003e Recommended torque is \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003e11.2 N•m (100 in•lbf)\u003c\/span\u003e. Maximum rated torque is 33.9 N•m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque (First Three Threads):\u003c\/strong\u003e Use recommended torque of \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003e7.5 N•m (66 in•lbf)\u003c\/span\u003e. Do not exceed 22.6 N•m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Use 16-24 AWG wire. Maximum extension cable length is \u003cspan style=\"color: #c7254e; font-weight: 600;\"\u003e305 meters (1,000 feet)\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Note:\u003c\/strong\u003e Avoid exposing probe below -34°C (-30°F) to protect pressure seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Barrier Required:\u003c\/strong\u003e Install with intrinsic safety barriers per drawing 141092 for Zone 0 applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush Mount Design:\u003c\/strong\u003e Zero tip length allows probe face to sit at or near mounting surface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eBently Nevada 330102-00-10-10-01-05\u003c\/strong\u003e 3300 XL 8 mm Probe with armor.\u003c\/li\u003e\n\u003cli\u003eFactory-attached ClickLoc connector with protector and 1.0m standard cable.\u003c\/li\u003e\n\u003cli\u003eMounting instructions and product documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e We ship via FedEx, UPS, or DHL for fast global delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does zero unthreaded tip mean?\u003c\/h3\u003e\n\u003cp\u003eThreads start immediately at probe face. Ideal for flush mounting where tip cannot extend beyond mounting surface.\u003c\/p\u003e\n\u003ch3\u003eWhat approvals does this probe have?\u003c\/h3\u003e\n\u003cp\u003eThis model carries CSA, ATEX, and IECEx certifications. Suitable for hazardous areas worldwide.\u003c\/p\u003e\n\u003ch3\u003eWhat is the connector protector?\u003c\/h3\u003e\n\u003cp\u003eIt shields the ClickLoc connection from debris and accidental impact. Adds durability in harsh environments.\u003c\/p\u003e\n\u003ch3\u003eCompatible with 3300 XL systems?\u003c\/h3\u003e\n\u003cp\u003eYes. This \u003cstrong\u003e330102-00-10-10-01-05\u003c\/strong\u003e works with all Bently Nevada 3300 XL proximitors and monitors.\u003c\/p\u003e\n\u003ch3\u003eWhat gap setting for vibration?\u003c\/h3\u003e\n\u003cp\u003eSet initial gap to -9 Vdc (approximately 1.27mm or 50 mils). This centers probe within linear range.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47476715946242,"sku":"330102-00-10-10-01-05","price":226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330102-00-10-10-01-05.jpg?v=1773642464","url":"https:\/\/www.nex-auto.com\/products\/330102-00-10-10-01-05-3300-xl-8mm-armored-probe-bently-nevada","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}