{"product_id":"330104-00-25-10-12-00-bently-nevada-1m-clickloc-probe","title":"330104-00-25-10-12-00 Bently Nevada 1m ClickLoc Probe","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 330104-00-25-10-12-00\u003c\/strong\u003e | Metric 3300 XL 8mm Proximity Probe\u003c\/h2\u003e\n\n\u003cp\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/span\u003e | \u003cstrong\u003eProduct No.:\u003c\/strong\u003e 330104-00-25-10-12-00 | \u003cstrong\u003eType:\u003c\/strong\u003e 3300 XL 8mm Proximity Probe with Armor | \u003cstrong\u003eThread:\u003c\/strong\u003e M10x1 (Metric) | \u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/p\u003e\n\n\u003ch2\u003eModel Number Breakdown\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e330104:\u003c\/strong\u003e 3300 XL 8mm Probe, M10x1 thread, with armor\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e Unthreaded length = 0mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e25:\u003c\/strong\u003e Overall case length = 250mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e10:\u003c\/strong\u003e Total cable length = 1.0 meter (3.3 feet)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e12:\u003c\/strong\u003e Miniature coaxial ClickLoc connector, FluidLoc cable\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e Agency approval = Not required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThread Size:\u003c\/strong\u003e M10x1 (metric thread)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase Length:\u003c\/strong\u003e 250mm (9.84 inches)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUnthreaded Length:\u003c\/strong\u003e 0mm (threads start at shoulder)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 1.0 meter (3.3 feet)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRPROBE at 1.0m:\u003c\/strong\u003e 7.59 ± 0.50 Ohms\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Miniature coaxial ClickLoc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e FluidLoc cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMeasurement Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e 2mm (80 mils) from 0.25mm to 2.3mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e -1 to -17 Vdc over linear range\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecommended Gap (Radial Vibration):\u003c\/strong\u003e -9 Vdc (approx 1.27mm \/ 50 mils)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 7.87 V\/mm (200 mV\/mil)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e -17.5 to -26 Vdc, nominal -24 Vdc\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe Tip Material:\u003c\/strong\u003e Polyphenylene sulfide (PPS)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe Case Material:\u003c\/strong\u003e AISI 303 or 304 stainless steel\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Thread Engagement:\u003c\/strong\u003e 15mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 323 grams per meter (11.4 oz per meter)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Miniature coaxial ClickLoc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e FluidLoc (fluid-resistant cable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTemperature Ratings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Operating:\u003c\/strong\u003e -52°C to +177°C (-62°F to +350°F)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtended Tip:\u003c\/strong\u003e Up to +218°C (+425°F)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtended Cable\/Connector:\u003c\/strong\u003e -51°C to +260°C (-60°F to +500°F)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePressure Seal Warning:\u003c\/strong\u003e Below -34°C (-30°F) may cause seal failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eField Wiring Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWire Gauge:\u003c\/strong\u003e 0.2 to 1.5 mm² (16 to 24 AWG)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecommended Cable:\u003c\/strong\u003e 3 conductor shielded triad, tinned field wiring\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Length:\u003c\/strong\u003e 305 meters (1,000 feet) between proximitor and monitor\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSignal Rolloff:\u003c\/strong\u003e See Figures 10 and 12 in manual for high frequency effects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHazardous Area Approvals (when installed with barriers\/isolators)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eia (Intrinsic Safety):\u003c\/strong\u003e Class I, Zone 0 AEx\/Ex ia IIC T5...T1 Ga; Class I, II, III Div 1, Groups A-G\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003enA \/ ec (Non-incendive):\u003c\/strong\u003e Class I, Zone 2 AEx\/Ex nA IIC T5...T1 Gc; Class I Div 2 Groups A-D\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRequires:\u003c\/strong\u003e Zener barriers per drawing 141092 or galvanic isolators for ia; Non-incendive circuit per drawing 140979 for nA\/ec\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHumidity Performance\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTest Standard:\u003c\/strong\u003e IEC 68-2-3 for up to 56 days at 93% RH\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePerformance Change:\u003c\/strong\u003e Less than 3% change in Average Scale Factor (ASF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFluidLoc Cable Feature\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFluidLoc cable:\u003c\/strong\u003e Designed for fluid-resistant applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBenefit:\u003c\/strong\u003e Withstands exposure to oils, coolants, and industrial fluids\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eClickLoc Connector:\u003c\/strong\u003e Miniature coaxial with positive locking mechanism\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e330104-00-25-10-12-00 probe assembly with 1.0m FluidLoc cable\u003c\/li\u003e\n    \u003cli\u003eM10x1 lock nut\u003c\/li\u003e\n    \u003cli\u003eCalibration certificate\u003c\/li\u003e\n    \u003cli\u003eInstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 0.4 kg (0.88 lb)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protective tube\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL (2-5 business days)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between 330104 and 330192 probes?\u003c\/strong\u003e\u003cbr\u003eA: 330104 has M10x1 metric thread. 330192 has 3\/8-24 UNF imperial thread. Choose based on your mounting port thread type.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is FluidLoc cable and when should I use it?\u003c\/strong\u003e\u003cbr\u003eA: FluidLoc cable is fluid-resistant cable designed for applications with exposure to oils, coolants, and industrial fluids. Standard cables may degrade in these environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum wall thickness for this 250mm case probe?\u003c\/strong\u003e\u003cbr\u003eA: With 250mm case and 0mm unthreaded length, maximum wall thickness is approximately 234mm (250mm minus 15mm thread engagement minus 1mm gap). Suitable for very thick machine casings.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: Can I use this probe in hazardous locations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when installed with appropriate zener barriers (drawing 141092) or galvanic isolators for ia rating, or non-incendive circuit (drawing 140979) for nA\/ec rating. The probe itself has no standalone approval but is certified for use with these barriers.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the recommended gap setting for radial vibration?\u003c\/strong\u003e\u003cbr\u003eA: -9 Vdc, which is approximately 1.27mm (50 mils) from the target surface. Use a voltmeter connected to the proximitor to verify the gap voltage during installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47658604888322,"sku":"330104-00-25-10-12-00","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330104-00-25-10-12-00.jpg?v=1776071898","url":"https:\/\/www.nex-auto.com\/products\/330104-00-25-10-12-00-bently-nevada-1m-clickloc-probe","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}