{"product_id":"330192-00-60-10-00-bently-nevada-3300-xl-8mm-cable-probe","title":"330192-00-60-10-00 Bently Nevada 3300 XL 8mm Cable Probe","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 330192-00-60-10-00\u003c\/strong\u003e 6 Inch Case 3300 XL ETR Probe\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong\u003e330192-00-60-10-00\u003c\/strong\u003e ETR probe\u003c\/span\u003e for 3300 XL series proximity systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 8 mm Eddy Current Transducer (ETR) probe with armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Size:\u003c\/strong\u003e 3\/8-24 UNF for standard mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmor:\u003c\/strong\u003e Yes, this model includes stainless steel armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e 00 = Not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Number Breakdown\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330192:\u003c\/strong\u003e Base model for 8mm ETR probe, 3\/8-24 UNF thread, with armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e Unthreaded length = 0.0 inches (minimum).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e60:\u003c\/strong\u003e Overall case length = 6.0 inches (152.4 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:\u003c\/strong\u003e Total cable length = 1.0 meter (3.3 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e Agency approval = Not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCase Length and Unthreaded Length Rules\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase length:\u003c\/strong\u003e 6.0 inches (152.4 mm) from mounting shoulder to tip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded length:\u003c\/strong\u003e 0.0 inches (minimum allowed).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical rule:\u003c\/strong\u003e Unthreaded length must be 0.8 inches less than case length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e 6.0 inch case - 0.0 inch unthreaded = 6.0 inch difference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequirement met:\u003c\/strong\u003e 6.0 inches exceeds required 0.8 inches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreaded portion:\u003c\/strong\u003e Full 6.0 inches available for mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe diameter:\u003c\/strong\u003e 8 mm tip for standard 3300 XL systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread size:\u003c\/strong\u003e 3\/8-24 UNF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum thread engagement:\u003c\/strong\u003e 0.563 inches (14.3 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase material:\u003c\/strong\u003e AISI 303 or 304 stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTip material:\u003c\/strong\u003e Polyphenylene sulfide (PPS).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable length:\u003c\/strong\u003e 1.0 meter (3.3 feet) with armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded section:\u003c\/strong\u003e None - threads start immediately at shoulder.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal DC Resistance (RPROBE):\u003c\/strong\u003e 7.59 ± 0.50 Ω at 1.0 meter length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement type:\u003c\/strong\u003e Center conductor to outer conductor resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable impedance:\u003c\/strong\u003e 75 Ω coaxial for system matching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear range:\u003c\/strong\u003e 2 mm (80 mils) standard 3300 XL performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 7.87 V\/mm (200 mV\/mil) at nominal gap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency response:\u003c\/strong\u003e 0 to 10 kHz DC coupled.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTemperature Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard operating range:\u003c\/strong\u003e -52°C to +177°C (-62°F to +350°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e Same as operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended temperature tip:\u003c\/strong\u003e Up to +218°C (+425°F) available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended temperature cable:\u003c\/strong\u003e -51°C to +260°C (-60°F to +500°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure seal warning:\u003c\/strong\u003e Below -34°C (-30°F) may cause premature seal failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication note:\u003c\/strong\u003e Standard range suits most industrial machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTemperature Classification Schedule\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor EPL Ga and Gc (Gas):\u003c\/strong\u003e T1 (-55°C to +232°C), T2 (-55°C to +177°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor EPL Ga and Gc (continued):\u003c\/strong\u003e T3 (-55°C to +120°C), T4 (-55°C to +80°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor EPL Ga and Gc (continued):\u003c\/strong\u003e T5 (-55°C to +40°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor EPL Dc (Dust):\u003c\/strong\u003e T280°C at -55°C to +232°C ambient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor EPL Dc (continued):\u003c\/strong\u003e T225°C at -55°C to +177°C, T170°C at -55°C to +120°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor EPL Dc (continued):\u003c\/strong\u003e T130°C at -55°C to +80°C, T105°C at -55°C to +100°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor EPL Dc (continued):\u003c\/strong\u003e T90°C at -55°C to +40°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What makes the \u003cstrong\u003e330192-00-60-10-00\u003c\/strong\u003e different from shorter or longer probes?\u003c\/strong\u003e\u003cbr\u003eA: This probe has 6.0 inch case length with zero unthreaded section. It fits medium thickness casings where 5 inch is too short and 8 inch is excessive. The 1.0 meter cable suits proximitors mounted near the machine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is zero unthreaded length acceptable for this probe?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The rule requires unthreaded length to be at least 0.8 inches less than case length. With 6.0 inch case and 0.0 inch unthreaded, the threaded portion is 6.0 inches. This far exceeds the 0.8 inch requirement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does the 1.0 meter cable mean for installation?\u003c\/strong\u003e\u003cbr\u003eA: The 1.0 meter built-in cable connects directly from probe to proximitor. For longer distances, add a 3300 XL extension cable. Total system length (probe cable + extension) must match the proximitor calibration label.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What temperature class ratings apply to this probe?\u003c\/strong\u003e\u003cbr\u003eA: For gas environments (EPL Ga\/Gc), ratings range from T1 (-55°C to +232°C) down to T5 (-55°C to +40°C). For dust environments (EPL Dc), surface temperatures vary from 280°C down to 90°C depending on ambient temperature range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use the \u003cstrong\u003e330192-00-60-10-00\u003c\/strong\u003e in freezing conditions?\u003c\/strong\u003e\u003cbr\u003eA: The probe operates down to -52°C, but Bently Nevada warns that exposure below -34°C may cause premature pressure seal failure. For sustained cold operation below -34°C, contact Bently about special sealing options or extended temperature range probes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47618725249282,"sku":"330192-00-60-10-00","price":174.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330192-00-60-10-00.jpg?v=1775201949","url":"https:\/\/www.nex-auto.com\/products\/330192-00-60-10-00-bently-nevada-3300-xl-8mm-cable-probe","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}