{"product_id":"330703-000-040-10-12-00-bently-nevada-metric-probe","title":"330703-000-040-10-12-00 Bently Nevada Metric Probe","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 330703-000-040-10-12-00\u003c\/strong\u003e | 11mm Metric Proximity Probe with FluidLoc Cable\u003c\/h2\u003e\n\n\u003cp\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/span\u003e | \u003cstrong\u003ePart Number:\u003c\/strong\u003e 330703-000-040-10-12-00 | \u003cstrong\u003eType:\u003c\/strong\u003e 3300 XL 11mm Proximity Probe | \u003cstrong\u003eThread:\u003c\/strong\u003e M14 x 1.5 Metric | \u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/p\u003e\n\n\u003ch2\u003eModel Number Breakdown\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e330703:\u003c\/strong\u003e 3300 XL 11mm Probe, M14 x 1.5 thread, without armor\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e000:\u003c\/strong\u003e Unthreaded length = 0 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e040:\u003c\/strong\u003e Overall case length = 40.0 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e10:\u003c\/strong\u003e Total cable length = 1.0 meter (3.3 feet)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e12:\u003c\/strong\u003e Miniature coaxial ClickLoc connector, FluidLoc cable\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e Agency approval = Not required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe Diameter:\u003c\/strong\u003e 11mm tip\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThread Size:\u003c\/strong\u003e M14 x 1.5 (metric)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase Length:\u003c\/strong\u003e 40.0 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUnthreaded Length:\u003c\/strong\u003e 0 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 1.0 meter (3.3 feet)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRPROBE at 1.0m:\u003c\/strong\u003e 5.9 ± 0.5 Ohms\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e 75 Ω triaxial, FEP insulated, FluidLoc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Miniature coaxial ClickLoc\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFluidLoc Cable Feature\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFluidLoc cable:\u003c\/strong\u003e Fluid-resistant for harsh environments\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBenefit:\u003c\/strong\u003e Withstands oils, coolants, and industrial fluids\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e No connector protector included (option 12 vs 11)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Wet environments, machinery with fluid exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTip Material:\u003c\/strong\u003e Polyphenylene sulfide (PPS)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase Material:\u003c\/strong\u003e AISI 304 stainless steel\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Thread Engagement:\u003c\/strong\u003e 21 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Rated Torque:\u003c\/strong\u003e 63.3 N·m (560 in·lb)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecommended Torque:\u003c\/strong\u003e 21.1 N·m (187 in·lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e -17.5 to -26 Vdc, nominal -24 Vdc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e Larger than 8mm probes (typically 3mm+ for 11mm)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Factory calibrated per 3300 XL standards\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Impedance:\u003c\/strong\u003e 75 Ω triaxial construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMagnetic Field Effects (60 Hz, up to 300 Gauss - 5m system)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAt 0.5mm gap (20 mils):\u003c\/strong\u003e 0.001 output voltage (mil pp\/gauss)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAt 2.5mm gap (100 mils):\u003c\/strong\u003e 0.009 output voltage (mil pp\/gauss)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAt 4.6mm gap (180 mils):\u003c\/strong\u003e 0.027 output voltage (mil pp\/gauss)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTemperature Ratings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating \u0026amp; Storage:\u003c\/strong\u003e -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePressure seal warning:\u003c\/strong\u003e Below -34°C may cause premature seal failure\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T1:\u003c\/strong\u003e -55°C to +232°C (EPL Ga\/Gc)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T2:\u003c\/strong\u003e -55°C to +177°C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T3:\u003c\/strong\u003e -55°C to +120°C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T4:\u003c\/strong\u003e -55°C to +80°C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T5:\u003c\/strong\u003e -55°C to +40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAgency Approval - None (00)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApproval option 00:\u003c\/strong\u003e No hazardous location certifications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafe area use only:\u003c\/strong\u003e Not certified for explosive atmospheres\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Non-hazardous industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConnector Option 11 vs 12 Comparison\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOption 11:\u003c\/strong\u003e ClickLoc connector with connector protector + FluidLoc cable\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOption 12:\u003c\/strong\u003e ClickLoc connector only + FluidLoc cable (no protector)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eChoose option 12 when:\u003c\/strong\u003e Connector protector not needed or will be installed immediately\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e330703-000-040-10-12-00 probe assembly with 1.0m FluidLoc cable\u003c\/li\u003e\n    \u003cli\u003eClickLoc connector\u003c\/li\u003e\n    \u003cli\u003eCalibration certificate\u003c\/li\u003e\n    \u003cli\u003eInstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 0.4 kg (0.88 lb)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protective box\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL (2-5 business days)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between option 11 and option 12 for connector and cable?\u003c\/strong\u003e\u003cbr\u003eA: Option 11 includes a connector protector plus FluidLoc cable. Option 12 includes FluidLoc cable only (no connector protector). Choose option 12 if you have a protector already or will connect immediately.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is FluidLoc cable and when should I use it?\u003c\/strong\u003e\u003cbr\u003eA: FluidLoc cable is fluid-resistant cable designed for applications with exposure to oils, coolants, and industrial fluids. Standard cables may degrade in these environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the recommended installation torque?\u003c\/strong\u003e\u003cbr\u003eA: Recommended torque is 21.1 N·m (187 in·lb). Maximum rated torque is 63.3 N·m (560 in·lb). Do not exceed maximum to avoid thread damage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: Is this probe approved for hazardous locations?\u003c\/strong\u003e\u003cbr\u003eA: No. Option 00 means no hazardous location certifications. Use only in safe (non-classified) areas. For hazardous locations, choose option 05 (multiple approvals).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the advantage of 11mm probe over 8mm?\u003c\/strong\u003e\u003cbr\u003eA: 11mm probes offer longer linear range (typically 3mm+ vs 2mm for 8mm). Better for large shaft movement, thrust position monitoring, and applications with wider gap variations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47666534777090,"sku":"330703-000-040-10-12-00","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330703-000-040-10-12-00.jpg?v=1776325873","url":"https:\/\/www.nex-auto.com\/products\/330703-000-040-10-12-00-bently-nevada-metric-probe","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}