{"product_id":"330703-000-100-10-11-05-bently-nevada-100mm-probe","title":"330703-000-100-10-11-05 Bently Nevada 100mm Probe","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 330703-000-100-10-11-05\u003c\/strong\u003e | 11mm Long Case Metric Proximity Probe\u003c\/h2\u003e\n\n\u003cp\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/span\u003e | \u003cstrong\u003ePart Number:\u003c\/strong\u003e 330703-000-100-10-11-05 | \u003cstrong\u003eType:\u003c\/strong\u003e 3300 XL 11mm Proximity Probe | \u003cstrong\u003eThread:\u003c\/strong\u003e M14 x 1.5 Metric | \u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/p\u003e\n\n\u003ch2\u003eModel Number Breakdown\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e330703:\u003c\/strong\u003e 3300 XL 11mm Probe, M14 x 1.5 thread, without armor\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e000:\u003c\/strong\u003e Unthreaded length = 0 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e100:\u003c\/strong\u003e Overall case length = 100 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e10:\u003c\/strong\u003e Total cable length = 1.0 meter (3.3 feet)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e11:\u003c\/strong\u003e Miniature coaxial ClickLoc connector with connector protector, FluidLoc cable\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e05:\u003c\/strong\u003e Agency approval = Multiple Approvals (CSA\/ATEX\/IECEx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe Diameter:\u003c\/strong\u003e 11mm tip\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThread Size:\u003c\/strong\u003e M14 x 1.5 (metric)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase Length:\u003c\/strong\u003e 100 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUnthreaded Length:\u003c\/strong\u003e 0 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 1.0 meter (3.3 feet)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRPROBE at 1.0m:\u003c\/strong\u003e 5.9 ± 0.5 Ohms\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e 75 Ω triaxial, FEP insulated, FluidLoc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Miniature coaxial ClickLoc with connector protector\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eLong Case Design (100mm)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e100mm case length:\u003c\/strong\u003e Longer than standard 40mm or 50mm cases\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Thick machine casings, deep recessed mounting ports\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWall thickness capacity:\u003c\/strong\u003e Suitable for casings up to approximately 85mm thick\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThreaded portion:\u003c\/strong\u003e Full 100mm threaded for maximum engagement options\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFluidLoc Cable Feature\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFluidLoc cable:\u003c\/strong\u003e Fluid-resistant for harsh environments\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBenefit:\u003c\/strong\u003e Withstands oils, coolants, and industrial fluids\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector protector:\u003c\/strong\u003e Included for storage and transport\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Wet environments, machinery with fluid exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTip Material:\u003c\/strong\u003e Polyphenylene sulfide (PPS)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase Material:\u003c\/strong\u003e AISI 304 stainless steel\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Thread Engagement:\u003c\/strong\u003e 21 mm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Rated Torque:\u003c\/strong\u003e 63.3 N·m (560 in·lb)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecommended Torque:\u003c\/strong\u003e 21.1 N·m (187 in·lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e -17.5 to -26 Vdc, nominal -24 Vdc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e Larger than 8mm probes (typically 3mm+ for 11mm)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Factory calibrated per 3300 XL standards\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Impedance:\u003c\/strong\u003e 75 Ω triaxial construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMagnetic Field Effects (60 Hz, up to 300 Gauss - 5m system)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAt 0.5mm gap (20 mils):\u003c\/strong\u003e 0.001 output voltage (mil pp\/gauss)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAt 2.5mm gap (100 mils):\u003c\/strong\u003e 0.009 output voltage (mil pp\/gauss)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAt 4.6mm gap (180 mils):\u003c\/strong\u003e 0.027 output voltage (mil pp\/gauss)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTemperature Ratings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating \u0026amp; Storage:\u003c\/strong\u003e -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePressure seal warning:\u003c\/strong\u003e Below -34°C may cause premature seal failure\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T1:\u003c\/strong\u003e -55°C to +232°C (EPL Ga\/Gc)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T2:\u003c\/strong\u003e -55°C to +177°C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T3:\u003c\/strong\u003e -55°C to +120°C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T4:\u003c\/strong\u003e -55°C to +80°C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Class T5:\u003c\/strong\u003e -55°C to +40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAgency Approval - Multiple Approvals (05)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified for North American hazardous locations\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved for European explosive atmospheres\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for worldwide use\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Refineries, chemical plants, gas pipelines, offshore platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e330703-000-100-10-11-05 probe assembly with 1.0m FluidLoc cable\u003c\/li\u003e\n    \u003cli\u003eClickLoc connector with connector protector\u003c\/li\u003e\n    \u003cli\u003eCalibration certificate\u003c\/li\u003e\n    \u003cli\u003eInstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 0.5 kg (1.1 lb)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protective box\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL (2-5 business days)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: Why choose 100mm case length for an 11mm probe?\u003c\/strong\u003e\u003cbr\u003eA: The 100mm case reaches through very thick machine casings (up to approximately 85mm). Ideal for large turbines, compressors with thick walls, or deep recessed mounting ports where standard 40mm or 50mm cases cannot reach.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What approvals does option 05 include?\u003c\/strong\u003e\u003cbr\u003eA: Multiple Approvals include CSA (North America), ATEX (Europe), and IECEx (international) for global hazardous location use.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is FluidLoc cable and when should I use it?\u003c\/strong\u003e\u003cbr\u003eA: FluidLoc cable is fluid-resistant cable designed for applications with exposure to oils, coolants, and industrial fluids. The connector protector keeps the connector clean during storage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the recommended installation torque for the 100mm case?\u003c\/strong\u003e\u003cbr\u003eA: Recommended torque is 21.1 N·m (187 in·lb). Maximum rated torque is 63.3 N·m (560 in·lb). The longer case requires careful alignment to avoid cross-threading.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the advantage of 11mm probe over 8mm for long case applications?\u003c\/strong\u003e\u003cbr\u003eA: 11mm probes offer longer linear range (typically 3mm+ vs 2mm for 8mm). This is beneficial when mounting through thick walls where gap settings may be less precise or shaft movement is larger.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47666520752386,"sku":"330703-000-100-10-11-05","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330703-000-100-10-11-05.jpg?v=1776325515","url":"https:\/\/www.nex-auto.com\/products\/330703-000-100-10-11-05-bently-nevada-100mm-probe","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}