{"product_id":"330930-040-01-05-armored-nsv-cable-bently-nevada","title":"330930-040-01-05 Armored NSv Cable Bently Nevada","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 330930-040-01-05\u003c\/strong\u003e Armored 3300 NSv Extension Cable\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong\u003e330930-040-01-05\u003c\/strong\u003e extension cable\u003c\/span\u003e for 3300 NSv Proximitor Sensor systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 75 Ω coaxial extension cable with full stainless steel armor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 4.0 meters (13.1 feet) as specified by -040 option.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector Option:\u003c\/strong\u003e 01 = With stainless steel armor, with FEP outer jacket.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e 05 = Multiple Approvals (international certifications).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 1.5 kg (3.3 lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eArmor Construction Details\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArmor Material:\u003c\/strong\u003e Flexible AISI 302 stainless steel.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e FEP (fluoroethylene propylene) over the armor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArmor Function:\u003c\/strong\u003e Protects cable from crushing, abrasion, and cutting.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFlexibility:\u003c\/strong\u003e Armor remains flexible for routing in tight spaces.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eChemical Resistance:\u003c\/strong\u003e FEP jacket resists oils, acids, and solvents.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e Full -51°C to +177°C range with armor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCable Electrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e 75 Ω coaxial for proper impedance matching.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInsulation Material:\u003c\/strong\u003e FEP dielectric throughout.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCenter Conductor DC Resistance:\u003c\/strong\u003e 0.220 Ω\/m (0.067 Ω\/ft).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShield DC Resistance:\u003c\/strong\u003e 0.066 Ω\/m (0.020 Ω\/ft).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTypical Capacitance:\u003c\/strong\u003e 69.9 pF\/m (21.3 pF\/ft).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector Material:\u003c\/strong\u003e Gold-plated brass for low contact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTemperature Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -51°C to +177°C (-60°F to +351°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e Same range as operating.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArmor Temperature Limit:\u003c\/strong\u003e Stainless steel handles full range.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFEP Jacket Limit:\u003c\/strong\u003e Maintains integrity to +177°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLow Temperature Performance:\u003c\/strong\u003e Remains flexible at -51°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication Suitability:\u003c\/strong\u003e Turbines, compressors, extreme environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Length Integration\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCritical Rule:\u003c\/strong\u003e Probe length + extension cable length = Proximitor total length.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExample Calculation:\u003c\/strong\u003e 1.0m probe + 4.0m cable = 5.0m system total.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCalibration Impact:\u003c\/strong\u003e Factory calibration assumes specific total length.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDo Not Mix:\u003c\/strong\u003e Different cable lengths alter system response.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVerification Step:\u003c\/strong\u003e Check Proximitor label for approved total length.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eField Modification:\u003c\/strong\u003e Never cut or splice this cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eLinear Range and Gap Settings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e 1.5 mm (60 mils) total measurement span.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRange Start:\u003c\/strong\u003e 0.25 mm (10 mils) from target surface.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRange End:\u003c\/strong\u003e 1.75 mm (70 mils) from target surface.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage at Start:\u003c\/strong\u003e Approximately -1 Vdc.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage at End:\u003c\/strong\u003e Approximately -13 Vdc.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecommended Gap:\u003c\/strong\u003e 1.0 mm (40 mils) for optimal linearity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage at Recommended Gap:\u003c\/strong\u003e Approximately -7 to -8 Vdc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eField Wiring Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Field Wiring Length:\u003c\/strong\u003e 305 meters (1,000 feet) to monitor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecommended Cable:\u003c\/strong\u003e Three-conductor shielded triad.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWire Gauge Range:\u003c\/strong\u003e 0.2 to 1.5 mm² (16 to 24 AWG).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWith Ferrules:\u003c\/strong\u003e 0.25 to 0.75 mm² (18 to 23 AWG).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFrequency Rolloff:\u003c\/strong\u003e See Figures 16 and 17 in manual for high frequency effects.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNoise Prevention:\u003c\/strong\u003e Keep field wiring away from power cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTensile Strength Ratings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe case to probe lead:\u003c\/strong\u003e 220 N (50 lb) maximum.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe lead to extension cable connector:\u003c\/strong\u003e 220 N (50 lb) maximum.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe case to stainless steel armor:\u003c\/strong\u003e 220 N (50 lb) maximum.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArmor Pull Strength:\u003c\/strong\u003e Armor adds significant pull resistance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInstallation Advice:\u003c\/strong\u003e Pull by armor or connector body, not the cable.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eService Loop:\u003c\/strong\u003e Leave slack at both ends for strain relief.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAgency Approval Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApproval Code 05:\u003c\/strong\u003e Multiple Approvals (international).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIncluded Certifications:\u003c\/strong\u003e CSA, ATEX, IECEx typically included.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHazardous Location Rating:\u003c\/strong\u003e Suitable for Class I, Division 2 areas.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGlobal Use:\u003c\/strong\u003e Approved for North America, Europe, and international.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Approval certificates available upon request.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInstallation Compliance:\u003c\/strong\u003e Follow local hazardous area codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConnector Care and Maintenance\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e 3300 NSv series gold-plated brass.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArmor Termination:\u003c\/strong\u003e Armor securely crimped to connector body.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eKeep Clean:\u003c\/strong\u003e Dirt and moisture cause signal degradation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHand-Tight Only:\u003c\/strong\u003e Never use tools on connector coupling nut.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInspect Before Use:\u003c\/strong\u003e Check for bent pins or damaged threads.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReplace If Damaged:\u003c\/strong\u003e Damaged connectors create intermittent signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatibility Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompatible Probes:\u003c\/strong\u003e 3300 NSv series proximity probes only.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompatible Proximitor:\u003c\/strong\u003e 3300 NSv Proximitor Sensor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompatible Rack:\u003c\/strong\u003e 3500 Series monitoring systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNot Compatible With:\u003c\/strong\u003e Standard 3300 XL probes (different connector).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Look for NSv marking on probe and proximitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhen to Choose Armored Cable (Option 01)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect Burial:\u003c\/strong\u003e Armor protects against soil and rocks.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExposed Runs:\u003c\/strong\u003e Cable not inside conduit needs armor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh Traffic Areas:\u003c\/strong\u003e Prevents damage from foot or vehicle traffic.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAbrasion Risk:\u003c\/strong\u003e Sharp edges or vibrating surfaces.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRodent Prone Areas:\u003c\/strong\u003e Stainless steel resists gnawing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutdoor Installations:\u003c\/strong\u003e FEP jacket with armor provides UV protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtension Cable:\u003c\/strong\u003e \u003cstrong\u003e330930-040-01-05\u003c\/strong\u003e with connectors on both ends.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArmor Type:\u003c\/strong\u003e Flexible AISI 302 SST with FEP outer jacket.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Installation instruction sheet.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApproval Documents:\u003c\/strong\u003e Multiple approval certification references.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNo Connector Protector:\u003c\/strong\u003e Option 01 does not include protector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 1.5 kg (3.3 lb).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Coiled in protective cardboard box.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBox Dimensions:\u003c\/strong\u003e Approximately 35 x 35 x 10 cm.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFedEx:\u003c\/strong\u003e 2-3 business days worldwide.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUPS:\u003c\/strong\u003e 2-4 business days.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDHL:\u003c\/strong\u003e 3-5 business days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between option 01 and option 03 for this cable?\u003c\/strong\u003e\u003cbr\u003e\n    A: Option 01 includes stainless steel armor with FEP outer jacket for maximum protection. Option 03 has no armor and includes a connector protector. Choose 01 for exposed or buried installations.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What does agency approval code 05 (Multiple Approvals) include?\u003c\/strong\u003e\u003cbr\u003e\n    A: Code 05 typically includes CSA for North America, ATEX for Europe, and IECEx for international hazardous locations. This cable is certified for global use in Class I, Division 2 areas.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: Can I use the \u003cstrong\u003e330930-040-01-05\u003c\/strong\u003e with standard 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003e\n    A: No. This cable is for 3300 NSv systems only. NSv uses different connector design and 75Ω impedance. Using with 3300 XL will cause signal errors and may damage connectors.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: How do I calculate total system length with this armored cable?\u003c\/strong\u003e\u003cbr\u003e\n    A: Add probe length plus extension cable length. Example: 0.5m probe + 4.0m cable = 4.5m total. This total must match the Proximitor Sensor calibration label exactly.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What temperature range does the armored \u003cstrong\u003e330930-040-01-05\u003c\/strong\u003e handle?\u003c\/strong\u003e\u003cbr\u003e\n    A: The cable handles -51°C to +177°C (-60°F to +351°F). The stainless steel armor and FEP jacket maintain full performance across this entire range, suitable for turbines and compressors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47618605187330,"sku":"330930-040-01-05","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330930-040-01-05.jpg?v=1775199867","url":"https:\/\/www.nex-auto.com\/products\/330930-040-01-05-armored-nsv-cable-bently-nevada","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}