{"product_id":"330930-065-03-00-6-5m-nsv-cable-bently-nevada","title":"330930-065-03-00 6.5m NSv Cable Bently Nevada","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 330930-065-03-00\u003c\/strong\u003e 6.5 Meter NSv Extension Cable\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong\u003e330930-065-03-00\u003c\/strong\u003e extension cable\u003c\/span\u003e for 3300 NSv Proximitor Sensor systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 75 Ω coaxial extension cable without armor, includes connector protector.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 6.5 meters (21.3 feet) as specified by -065 option.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector Option:\u003c\/strong\u003e 03 = Without stainless steel armor, with connector protector.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e 00 = Not required (no hazardous location certifications).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 1.5 kg (3.3 lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eLong Cable Length Applications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e6.5 meter reach:\u003c\/strong\u003e Spans greater distance from probe to proximitor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTypical use case:\u003c\/strong\u003e Proximitor rack located farther from machine.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eControl room mounting:\u003c\/strong\u003e Allows proximitor installation in safe area.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLarge machinery:\u003c\/strong\u003e Suitable for turbines, compressors, and generators.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCombination example:\u003c\/strong\u003e 0.5m probe + 6.5m cable = 7.0m system total.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFlexibility:\u003c\/strong\u003e Unarmored design easier to route through conduit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCable Electrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e 75 Ω coaxial for precise impedance matching.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInsulation Material:\u003c\/strong\u003e FEP (fluoroethylene propylene) dielectric.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCenter Conductor DC Resistance:\u003c\/strong\u003e 0.220 Ω\/m (0.067 Ω\/ft).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShield DC Resistance:\u003c\/strong\u003e 0.066 Ω\/m (0.020 Ω\/ft).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTypical Capacitance:\u003c\/strong\u003e 69.9 pF\/m (21.3 pF\/ft).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e Maintains performance over full 6.5 meter length.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector Material:\u003c\/strong\u003e Gold-plated brass for low resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTemperature Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -51°C to +177°C (-60°F to +351°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e Same range as operating.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFEP Rating:\u003c\/strong\u003e Maintains electrical properties across full range.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLow Temperature:\u003c\/strong\u003e Cable remains flexible at -51°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh Temperature:\u003c\/strong\u003e Withstands +177°C continuously.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector Rating:\u003c\/strong\u003e Gold-plated brass handles full temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Length Integration Rules\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCritical Rule:\u003c\/strong\u003e Probe length + extension cable length = Proximitor total length.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExample with 6.5m cable:\u003c\/strong\u003e 1.0m probe + 6.5m cable = 7.5m system total.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShorter probe option:\u003c\/strong\u003e 0.5m probe + 6.5m cable = 7.0m system total.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCalibration impact:\u003c\/strong\u003e Factory calibration assumes specific total length.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDo not mix lengths:\u003c\/strong\u003e Using wrong cable changes system response.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Check Proximitor label for approved total length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eLinear Range and Gap Settings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e 1.5 mm (60 mils) total measurement span.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRange Start:\u003c\/strong\u003e 0.25 mm (10 mils) from target surface.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRange End:\u003c\/strong\u003e 1.75 mm (70 mils) from target surface.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage at start:\u003c\/strong\u003e Approximately -1 Vdc.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage at end:\u003c\/strong\u003e Approximately -13 Vdc.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecommended Gap:\u003c\/strong\u003e 1.0 mm (40 mils) for best linearity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage at recommended gap:\u003c\/strong\u003e Approximately -7 to -8 Vdc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eField Wiring Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum field wiring:\u003c\/strong\u003e 305 meters (1,000 feet) from proximitor to monitor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecommended cable:\u003c\/strong\u003e Three-conductor shielded triad.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWire gauge range:\u003c\/strong\u003e 0.2 to 1.5 mm² (16 to 24 AWG).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWith ferrules:\u003c\/strong\u003e 0.25 to 0.75 mm² (18 to 23 AWG).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFrequency rolloff:\u003c\/strong\u003e See Figures 16 and 17 in product manual.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNoise reduction:\u003c\/strong\u003e Keep field wiring away from power cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eUnarmored Design Benefits (Option 03)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLighter weight:\u003c\/strong\u003e Easier to handle than armored version.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMore flexible:\u003c\/strong\u003e Bends tighter for conduit pulls.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLower cost:\u003c\/strong\u003e No stainless steel armor reduces price.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector protector included:\u003c\/strong\u003e Plastic cover for storage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBest for conduit:\u003c\/strong\u003e Conduit provides physical protection.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIndoor use:\u003c\/strong\u003e Suitable for clean, protected environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConnector Protector Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIncluded:\u003c\/strong\u003e Plastic protector screws onto connector.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePurpose:\u003c\/strong\u003e Prevents dirt and moisture ingress during storage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProtects pins:\u003c\/strong\u003e Keeps gold-plated contacts clean.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUse when disconnected:\u003c\/strong\u003e Install protector on both ends.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRemove before connecting:\u003c\/strong\u003e Protector must come off for installation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReplace if lost:\u003c\/strong\u003e Generic protectors available from Bently Nevada.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTensile Strength Ratings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe case to probe lead:\u003c\/strong\u003e 220 N (50 lb) maximum.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe lead to extension cable connector:\u003c\/strong\u003e 220 N (50 lb) maximum.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWithout armor:\u003c\/strong\u003e Same ratings apply to unarmored cable.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInstallation advice:\u003c\/strong\u003e Pull by connector body, not cable jacket.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eService loop:\u003c\/strong\u003e Leave slack at both ends for strain relief.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAvoid sharp bends:\u003c\/strong\u003e Minimum bend radius is 10x cable diameter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConnector Care and Maintenance\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eKeep connectors clean:\u003c\/strong\u003e Dirt causes signal noise and drift.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUse protector when disconnected:\u003c\/strong\u003e Always install for storage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInspect before each connection:\u003c\/strong\u003e Look for bent pins or damage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHand-tighten only:\u003c\/strong\u003e Never use pliers or wrenches on coupling nut.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReplace if damaged:\u003c\/strong\u003e Damaged connectors cause intermittent signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatibility Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompatible Probes:\u003c\/strong\u003e 3300 NSv series proximity probes only.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompatible Proximitor:\u003c\/strong\u003e 3300 NSv Proximitor Sensor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompatible Rack:\u003c\/strong\u003e 3500 Series monitoring systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNot compatible with:\u003c\/strong\u003e Standard 3300 XL probes.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Look for NSv marking on all components.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMixing systems:\u003c\/strong\u003e Will cause signal errors and possible damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAgency Approval Note (Code 00)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApproval code 00:\u003c\/strong\u003e No hazardous location certifications.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafe area use only:\u003c\/strong\u003e Not approved for Class I, Division 2.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard compliance:\u003c\/strong\u003e Meets basic electrical safety standards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCost savings:\u003c\/strong\u003e Lower price without approval fees.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUpgrade path:\u003c\/strong\u003e Order code 05 for multiple approvals.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Suitable for non-hazardous industrial areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtension cable:\u003c\/strong\u003e \u003cstrong\u003e330930-065-03-00\u003c\/strong\u003e with connectors on both ends.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector protector:\u003c\/strong\u003e Installed on one connector for storage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Installation instruction sheet.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNo armor:\u003c\/strong\u003e This is unarmored option 03.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 1.5 kg (3.3 lb).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Coiled in protective cardboard box.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBox dimensions:\u003c\/strong\u003e Approximately 35 x 35 x 10 cm.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFedEx:\u003c\/strong\u003e 2-3 business days worldwide.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUPS:\u003c\/strong\u003e 2-4 business days.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDHL:\u003c\/strong\u003e 3-5 business days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: Why would I choose the 6.5 meter \u003cstrong\u003e330930-065-03-00\u003c\/strong\u003e over a shorter cable?\u003c\/strong\u003e\u003cbr\u003e\n    A: Use this longer cable when your proximitor mounts farther from the probe. Total system length (probe + cable) must match the Proximitor calibration. This 6.5m cable works with 0.5m or 1.0m probes for 7.0m or 7.5m total systems.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What does option 03 (no armor, with connector protector) mean for installation?\u003c\/strong\u003e\u003cbr\u003e\n    A: Option 03 means the cable has no stainless steel armor but includes a plastic connector protector. Use this cable inside conduit where the conduit provides physical protection. The protector keeps connectors clean during storage and shipping.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: Can I use the \u003cstrong\u003e330930-065-03-00\u003c\/strong\u003e in hazardous locations?\u003c\/strong\u003e\u003cbr\u003e\n    A: No. Agency approval code 00 means no hazardous location certifications. For Class I, Division 2 areas, order code 05 (Multiple Approvals) instead. Code 00 is for safe area installations only.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What temperature range does this 6.5 meter cable handle?\u003c\/strong\u003e\u003cbr\u003e\n    A: The FEP insulation handles -51°C to +177°C (-60°F to +351°F). The unarmored design maintains flexibility at low temperatures and integrity at high temperatures, suitable for turbine and compressor environments.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: How do I calculate total system length with this 6.5m cable?\u003c\/strong\u003e\u003cbr\u003e\n    A: Add your probe length to 6.5 meters. Example: 0.5m probe + 6.5m cable = 7.0m total. Example 2: 1.0m probe + 6.5m cable = 7.5m total. Check your Proximitor label for the approved total length before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47618625372418,"sku":"330930-065-03-00","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330930-065-03-00.jpg?v=1775199989","url":"https:\/\/www.nex-auto.com\/products\/330930-065-03-00-6-5m-nsv-cable-bently-nevada","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}