{"product_id":"abb-v18345-1010251001-tzidc-120-valve-positioner","title":"ABB V18345-1010251001 TZIDC-120 Valve Positioner","description":"\u003ch2\u003e\u003cstrong\u003eABB V18345-1010251001 TZIDC-120 Intelligent Valve Positioner\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eV18345-1010251001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e TZIDC-120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Intelligent Positioner with indicator and operator panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e Two-wire 4...20 mA with LKS adapter connector plug\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion Protection:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Function:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003eSingle acting, fail freeze\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Cable thread M20 x 1.5; air pipe thread 1\/4-18 NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption Module:\u003c\/strong\u003e Plug-in analog position feedback, signal range 4...20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Position Feedback Kit:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e Standard varnish and coding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Aluminium, varnished, IP 65 (NEMA 4X)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Linear actuators per DIN\/IEC 534 \/ NAMUR or rotary actuators per VDI\/VDE 3845, integral mounting ready\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Pressure:\u003c\/strong\u003e 1.4...6 bar (20...90 psi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Consumption:\u003c\/strong\u003e \u0026lt; 0.03 kg\/h \/ 0.015 scfm, independent of supply pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance and Control Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput 1 Increasing:\u003c\/strong\u003e Increasing signal 0...100% raises output pressure OUT 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput 1 Decreasing:\u003c\/strong\u003e Increasing signal 0...100% lowers output pressure OUT 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAction (Signal) Direct:\u003c\/strong\u003e Signal 4...20 mA equals position 0...100%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAction (Signal) Reverse:\u003c\/strong\u003e Signal 20...4 mA equals position 0...100%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharacteristic Curve:\u003c\/strong\u003e Linear, equal percentage 1:25 or 1:50 or 25:1 or 50:1, freely configurable with 20 reference points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharacteristic Deviation:\u003c\/strong\u003e ≤ 0.5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTolerance Band:\u003c\/strong\u003e 0.3...10%, adjustable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDead Band:\u003c\/strong\u003e 0.1...10%, adjustable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution (A\/D Conversion):\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u0026gt; 4000 steps\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Rate:\u003c\/strong\u003e 20 msec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfluence of Ambient Temperature:\u003c\/strong\u003e ≤ 0.5% for every 10 °C change\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfluence of Vibration:\u003c\/strong\u003e ≤ ± 1% up to 10 g and 80 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeismic Requirements:\u003c\/strong\u003e Meets DIN\/IEC 68-3-3 Class III for strong and strongest earthquakes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfluence of Mounting Orientation:\u003c\/strong\u003e No effect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the input signal range of the V18345-1010251001?\u003c\/strong\u003e\u003cbr\u003eA: The unit accepts a two-wire 4...20 mA signal with LKS adapter connector plug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this positioner support both linear and rotary actuators?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it mounts to linear actuators per DIN\/IEC 534 \/ NAMUR and rotary actuators per VDI\/VDE 3845.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the supply pressure range?\u003c\/strong\u003e\u003cbr\u003eA: The supply pressure range is 1.4...6 bar (20...90 psi), and you must not exceed the actuator's maximum pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What happens when electrical power fails?\u003c\/strong\u003e\u003cbr\u003eA: The single-acting output provides fail freeze, so the actuator holds its last position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the resolution of the A\/D conversion?\u003c\/strong\u003e\u003cbr\u003eA: The resolution exceeds 4000 steps for precise valve positioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the analog position feedback module included?\u003c\/strong\u003e\u003cbr\u003eA: Yes, this configuration includes a plug-in analog position feedback module with 4...20 mA signal range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What are the cable and air pipe thread sizes?\u003c\/strong\u003e\u003cbr\u003eA: The cable thread is M20 x 1.5, and the air pipe thread is 1\/4-18 NPT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How does vibration affect the positioner?\u003c\/strong\u003e\u003cbr\u003eA: Vibration influence stays within ± 1% up to 10 g and 80 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How long does shipping take?\u003c\/strong\u003e\u003cbr\u003eA: We dispatch within 5 days and use FedEx, UPS, or DHL for delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48468879016194,"sku":"V18345-1010251001","price":208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/V18345-1010251001.jpg?v=1789009391","url":"https:\/\/www.nex-auto.com\/products\/abb-v18345-1010251001-tzidc-120-valve-positioner","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}