{"product_id":"bently-nevada-2300-25-02-monitor-with-spa-outputs","title":"Bently Nevada 2300\/25-02 Monitor with SPA Outputs","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 2300\/25-02\u003c\/strong\u003e | Monitor with SPA Outputs\u003c\/h2\u003e\n\n\u003cp\u003e\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/span\u003e | \u003cstrong\u003ePart Number:\u003c\/strong\u003e 2300\/25-02 | \u003cstrong\u003eType:\u003c\/strong\u003e Monitor with SPA Outputs | \u003cstrong\u003eApproval:\u003c\/strong\u003e ATEX, IECEx, CSA (Multiple Explosive Atmosphere Certifications) | \u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/p\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 18 to 36 Vdc, maximum 7.5 Watts\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to +65°C (-22°F to +149°F)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e Up to 95% non-condensing\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVibration Limitation:\u003c\/strong\u003e 3g\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.03 kg (2.26 lbs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel mount or DIN rail (adapter included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Dimensions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 127 mm (5 inches)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 127 mm (5 inches)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 76.2 mm (3 inches)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact design:\u003c\/strong\u003e Fits in standard industrial enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInput Channels\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eICP Accelerometers:\u003c\/strong\u003e 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV\/g scale factor, 2 to 80 g peak full scale\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVelocity:\u003c\/strong\u003e 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV\/in\/s scale factor, 0 to 50 in\/s peak full scale\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRadial Vibration:\u003c\/strong\u003e 0.2 Hz to 20 kHz bandpass filter, 5 to 1000 mV\/mil scale factor, 0 to 160 mil peak-peak full scale\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThrust Channel:\u003c\/strong\u003e 5 to 1000 mV\/mil scale factor range\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProcess Variable Channel:\u003c\/strong\u003e Supports most units with default on temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpeed\/Keyphasor Input\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eKeyphasor transducers:\u003c\/strong\u003e Support multiple events per revolution\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSpeed input:\u003c\/strong\u003e Up to 20 kHz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThreshold voltage resolution:\u003c\/strong\u003e 0.1 Vdc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRPM range:\u003c\/strong\u003e 1 to 120,000 (proximity), 1 to 60,000 (proximity switch), 200 to 120,000 (magnetic pickup)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eProximity Transducer Interface\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e -22.8 to -25.2 Vdc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Rated Current:\u003c\/strong\u003e 15 mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShort Circuit Current:\u003c\/strong\u003e 15.1 to 23.6 mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±1% of full scale range\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInput Impedance (3-wire Voltage Mode):\u003c\/strong\u003e 10 kΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMeasurement Accuracy\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature Channel:\u003c\/strong\u003e ±1% of full scale range\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProximity Transducer:\u003c\/strong\u003e ±1% of full scale range\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIndependent 24-bit ADCs:\u003c\/strong\u003e On all input channels\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSPA Output Accuracy:\u003c\/strong\u003e High\/Low AC ±1% of full-scale at 100 Hz, DC GAP ±0.5V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutputs\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBuffered Outputs (BNC):\u003c\/strong\u003e 2 vibration outputs, 1 speed output\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Two dry-contact outputs, epoxy sealed, single pole double throw\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRelay Contact Life:\u003c\/strong\u003e 100,000 cycles at 5A, 250 Vac; 200,000 at 1A, 24 Vdc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSPA Output (2300\/25):\u003c\/strong\u003e High AC 8 Vpp, Low AC 1.6 Vpp, DC GAP 0 to -20 Vdc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSPA Frequency Response:\u003c\/strong\u003e 10 Hz to 3000 Hz ±5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRelay Specifications (Hazardous Area)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum switched contact voltage and current:\u003c\/strong\u003e 6A at 24 Vac, 5A at 30 Vac, 5.8A at 24 Vdc, 4A at 30 Vdc\u003c\/li\u003e\n    \u003cli\u003eSuitable for explosive atmosphere installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCommunications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 10Base-T and 100Base-TX, conforms to IEEE802.3\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e RJ-45 for 10Base-T\/100Base-TX\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Cable Length:\u003c\/strong\u003e 100 meters (328 feet)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eData Storage\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNetwork disruption:\u003c\/strong\u003e Stores up to 5 alarm data captures\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRequires:\u003c\/strong\u003e System 1 Evolution 21.1 or newer, Firmware 3.2 or newer\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTrend Intervals:\u003c\/strong\u003e Pre-event 10 minutes at 1 second, 20 seconds at 100 milliseconds\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSpectrum\/Waveform:\u003c\/strong\u003e Pre-event 2.5 minutes at 10 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBattery Life (Real Time Clock)\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePowered:\u003c\/strong\u003e 38 years at 50°C (122°F)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUn-powered:\u003c\/strong\u003e 12 years at 50°C (122°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFront Panel LEDs\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOK:\u003c\/strong\u003e Monitor operating properly\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProtection Fault:\u003c\/strong\u003e Hardware fault impacting alarm determination\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUser Inhibit:\u003c\/strong\u003e Alarms\/relays intentionally inhibited\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBypass:\u003c\/strong\u003e User initiated bypass action\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRelay Status:\u003c\/strong\u003e Relays activated\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTX\/RX:\u003c\/strong\u003e Ethernet status and remote communication\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSPEED\/AUX Channel Status:\u003c\/strong\u003e Valid speed signal or operating correctly\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAlert LED:\u003c\/strong\u003e Any channel in alert state\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDanger LED:\u003c\/strong\u003e Any channel in danger state\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eLCD Display\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003eView machine speed readings\u003c\/li\u003e\n    \u003cli\u003eView vibration measurement values\u003c\/li\u003e\n    \u003cli\u003eView setpoints and configuration information\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eContact Inputs\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e3 contact capabilities with input terminals for:\u003c\/li\u003e\n    \u003cli\u003eConfiguration lock\u003c\/li\u003e\n    \u003cli\u003eLatched alarm\/relay reset function\u003c\/li\u003e\n    \u003cli\u003eMonitor bypass (activate 0 to 10 kΩ, de-activate 150 kΩ to infinite)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eButton Inputs\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003eExternal button to reset latched alarm and relay\u003c\/li\u003e\n    \u003cli\u003eOne buried button provides 3 functions:\n        \u003cul\u003e\n            \u003cli\u003eDisplay monitor information\u003c\/li\u003e\n            \u003cli\u003eLCD contrast adjustment\u003c\/li\u003e\n            \u003cli\u003eReset settings to default\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e2300\/25-02 monitor with SPA outputs\u003c\/li\u003e\n    \u003cli\u003eDIN rail mount assembly (adapter included)\u003c\/li\u003e\n    \u003cli\u003eMonitor configuration software\u003c\/li\u003e\n    \u003cli\u003eInstallation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.5 kg (3.3 lb) packaged\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Factory sealed box\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL (2-5 business days)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What approvals does the 2300\/25-02 have?\u003c\/strong\u003e\u003cbr\u003eA: Option 02 provides Multiple Explosive Atmosphere Certifications including ATEX (Europe), IECEx (international), and CSA (North America) for global hazardous location use.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the SPA output?\u003c\/strong\u003e\u003cbr\u003eA: SPA (Signal Processing Assembly) output provides High AC (8 Vpp), Low AC (1.6 Vpp), and DC GAP (0 to -20 Vdc) signals with frequency response of 10 Hz to 3000 Hz ±5% for external analysis.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: How many channels does this monitor support?\u003c\/strong\u003e\u003cbr\u003eA: The 2300\/25-02 supports multiple channel types including ICP accelerometers, velocity, radial vibration, thrust, process variable, temperature, speed\/Keyphasor, proximity switch, and magnetic pickup inputs.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the accuracy of the measurements?\u003c\/strong\u003e\u003cbr\u003eA: The monitor features independent 24-bit ADCs on all input channels with ±1% of full scale range accuracy for most measurements. DC GAP accuracy is ±0.5V.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: Does the monitor store data during network outages?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The 2300 can store up to 5 alarm data captures during network disruption between the 2300 and System 1. Requires System 1 Evolution 21.1 or newer and Firmware 3.2 or newer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47666454135042,"sku":"2300\/25-02","price":352.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/2300_25-02.jpg?v=1776320504","url":"https:\/\/www.nex-auto.com\/products\/bently-nevada-2300-25-02-monitor-with-spa-outputs","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}