{"product_id":"bently-nevada-330192-00-08-05-05-etr-probe","title":"Bently Nevada 330192-00-08-05-05 ETR Probe","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 330192-00-08-05-05\u003c\/strong\u003e Hazardous Location ETR Probe\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong\u003e330192-00-08-05-05\u003c\/strong\u003e ETR probe\u003c\/span\u003e for 3300 XL series.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 8 mm Eddy Current Transducer with stainless steel armor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThread:\u003c\/strong\u003e 3\/8-24 UNF.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e 05 = CSA, ATEX, IECEx multiple approvals.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eGlobal Hazardous Location Certifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified for North American hazardous locations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved for European explosive atmospheres.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for worldwide use.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Oil refineries, chemical plants, gas pipelines.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBenefit:\u003c\/strong\u003e One probe works in multiple regulatory regions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eUltra Short Design\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase length:\u003c\/strong\u003e Only 0.8 inches (20.3 millimeters).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable length:\u003c\/strong\u003e 0.5 meter (1.6 feet).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUnthreaded section:\u003c\/strong\u003e Zero - threads start at shoulder.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum wall thickness:\u003c\/strong\u003e 0.2 inches (5 millimeters).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBest for:\u003c\/strong\u003e Tight spaces and thin casings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRPROBE at 0.5 meter:\u003c\/strong\u003e 7.45 ± 0.50 Ohms.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e -17.5 to -26 Vdc, nominal -24 Vdc.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutput voltage swing:\u003c\/strong\u003e -2 to -18 Vdc over linear range.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 7.87 V\/mm (200 mV\/mil).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLinear range:\u003c\/strong\u003e 2 millimeters (80 mils).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFrequency response:\u003c\/strong\u003e 0 to 10 kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTemperature Ratings\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard operating:\u003c\/strong\u003e -52 to 177 degrees Celsius.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtended tip:\u003c\/strong\u003e Up to 218 degrees Celsius.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtended cable:\u003c\/strong\u003e -51 to 260 degrees Celsius.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePressure seal warning:\u003c\/strong\u003e Below -34 degrees Celsius may cause seal failure.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTemperature class T4:\u003c\/strong\u003e Suitable for most industrial gas groups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe diameter:\u003c\/strong\u003e 8 millimeters tip.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase material:\u003c\/strong\u003e AISI 303 or 304 stainless steel.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTip material:\u003c\/strong\u003e Polyphenylene sulfide (PPS).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum thread engagement:\u003c\/strong\u003e 0.563 inches.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArmor type:\u003c\/strong\u003e Stainless steel over cable.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Standard 3300 XL coaxial.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHumidity Performance\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTest standard:\u003c\/strong\u003e IEC 68-2-3 for up to 56 days.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTest humidity:\u003c\/strong\u003e 93 percent relative humidity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePerformance change:\u003c\/strong\u003e Less than 3 percent change in Average Scale Factor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResult:\u003c\/strong\u003e Excellent for high humidity environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePressure Seal Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSeal material:\u003c\/strong\u003e Viton O-ring between tip and case.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Seals differential pressure at mounting point.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFactory test:\u003c\/strong\u003e Not performed before shipment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCustom option:\u003c\/strong\u003e Contact design department for pressure testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProximitor:\u003c\/strong\u003e 3300 XL 8mm (330180-90-00).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtension cables:\u003c\/strong\u003e 3300 XL series only.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTarget material:\u003c\/strong\u003e Calibrated for AISI 4140 steel.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMonitoring systems:\u003c\/strong\u003e 3500 Series, 1900 Series, 2300 Series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe assembly:\u003c\/strong\u003e 330192-00-08-05-05 with 0.5m armored cable.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLock nut:\u003c\/strong\u003e 3\/8-24 UNF hex nut.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCalibration certificate:\u003c\/strong\u003e Individual sensitivity data.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Installation instructions.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector cap:\u003c\/strong\u003e Plastic protector for storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 0.3 kilograms (0.66 pounds).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Small cardboard tube.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL (2 to 5 business days).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What approvals does the 05 option include?\u003c\/strong\u003e\u003cbr\u003e\n    A: Option 05 includes CSA for North America, ATEX for Europe, and IECEx for international hazardous locations. This probe works globally without needing different models for each region.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum wall thickness for this 0.8 inch probe?\u003c\/strong\u003e\u003cbr\u003e\n    A: Safe maximum is 0.2 inches (5 millimeters). Calculation: 0.8 inch case minus 0.5 inch minimum thread engagement minus 0.06 inch gap minus 0.04 inch safety margin equals 0.2 inches maximum.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: Can I use this probe in temperatures below -34 degrees Celsius?\u003c\/strong\u003e\u003cbr\u003e\n    A: The probe operates to -52 degrees Celsius, but Bently Nevada warns that the Viton pressure seal may fail prematurely below -34 degrees Celsius. For sustained cold operation, contact Bently about special sealing materials.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between approval option 00 and 05?\u003c\/strong\u003e\u003cbr\u003e\n    A: Option 00 has no hazardous location certifications. Option 05 includes CSA, ATEX, and IECEx for use in explosive atmospheres. Use option 05 for refineries, chemical plants, and gas handling facilities.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: Does the 0.5 meter cable limit my installation distance?\u003c\/strong\u003e\u003cbr\u003e\n    A: You can add 3300 XL extension cables to reach longer distances. Total system length (probe cable plus extension) must match your proximitor calibration. Example: 0.5 meter probe plus 4.5 meter extension equals 5.0 meter system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47632220979458,"sku":"330192-00-08-05-05","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330192-00-08-05-05.jpg?v=1775640428","url":"https:\/\/www.nex-auto.com\/products\/bently-nevada-330192-00-08-05-05-etr-probe","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}