{"product_id":"bently-nevada-330192-00-28-05-00-short-probe","title":"Bently Nevada 330192-00-28-05-00 Short Probe","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 330192-00-28-05-00\u003c\/strong\u003e Compact Short Case 3300 XL ETR Probe\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong\u003e330192-00-28-05-00\u003c\/strong\u003e ETR probe\u003c\/span\u003e for 3300 XL series.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 8 mm Eddy Current Transducer with stainless steel armor.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThread:\u003c\/strong\u003e 3\/8-24 UNF.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSmallest in the 330192 Family\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase length:\u003c\/strong\u003e Only 2.8 inches (71.1 mm).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable length:\u003c\/strong\u003e Shortest available at 0.5 meter (1.6 feet).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUnthreaded section:\u003c\/strong\u003e Zero - threads start at shoulder.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTotal weight:\u003c\/strong\u003e Lightest among armored 8mm probes.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTarget market:\u003c\/strong\u003e Compact machinery with limited space.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAlternative to:\u003c\/strong\u003e Bulkier 3.0in, 6.0in, or 8.0in case probes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhere This Probe Excels\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTight bearing housings:\u003c\/strong\u003e Small pumps and fans.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThin wall casings:\u003c\/strong\u003e 1.5 to 2.5 inches thick.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRetrofit projects:\u003c\/strong\u003e Replaces older shorter probes.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLimited access areas:\u003c\/strong\u003e Wrench swing restricted.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePortable monitoring:\u003c\/strong\u003e Temporary installation on test stands.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM equipment:\u003c\/strong\u003e Built into new compact machines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCase Length vs Wall Thickness Guide\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e2.8in case works for:\u003c\/strong\u003e Walls up to 2.0 inches thick.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThread engagement needed:\u003c\/strong\u003e Minimum 0.5 inches.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRemaining length:\u003c\/strong\u003e 0.8 inches for tip extension past wall.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGap setting:\u003c\/strong\u003e 1.5mm (0.06in) from tip to shaft.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety margin:\u003c\/strong\u003e Tip will not hit shaft if wall is 2.0in or less.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDo not use on:\u003c\/strong\u003e Walls thicker than 2.2 inches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Characteristic at 0.5 Meter\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRPROBE:\u003c\/strong\u003e 7.45 ± 0.50 Ω.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompare to 1.0m probe:\u003c\/strong\u003e 7.59 Ω (0.14 Ω difference).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompare to 9.0m probe:\u003c\/strong\u003e 9.87 Ω (2.42 Ω difference).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShort cable advantage:\u003c\/strong\u003e Lowest possible resistance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSignal strength:\u003c\/strong\u003e Minimal attenuation over short distance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNoise pickup:\u003c\/strong\u003e Less susceptible than long cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eZero Unthreaded Section Explained\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat it means:\u003c\/strong\u003e No smooth metal at the tip before threads start.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVisual:\u003c\/strong\u003e Threads continue all the way to the probe tip.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhy choose this:\u003c\/strong\u003e Maximizes thread length on short case.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTrade-off:\u003c\/strong\u003e Cannot use copper crush washer at shoulder.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSealing method:\u003c\/strong\u003e Thread sealant (PTFE tape or pipe dope).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRule check:\u003c\/strong\u003e 2.8in case - 0in unthreaded = 2.8in difference. Required is 0.8in. Pass.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eArmor on Short Cable\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArmor type:\u003c\/strong\u003e AISI 302 stainless steel braid.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCoverage:\u003c\/strong\u003e Full 0.5 meter length.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector to probe:\u003c\/strong\u003e Armor terminates at both ends.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShort cable benefit:\u003c\/strong\u003e Easier to route in crowded junction boxes.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBend radius:\u003c\/strong\u003e 50mm minimum (tighter than long cables).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConduit size:\u003c\/strong\u003e 3\/4 inch sufficient for this short cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePressure Seal Reality Check\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eViton O-ring:\u003c\/strong\u003e Located inside probe tip assembly.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSeals against:\u003c\/strong\u003e Differential pressure across mounting.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNo factory test:\u003c\/strong\u003e Standard units ship untested.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShort probe note:\u003c\/strong\u003e Same seal as longer probes.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLow pressure OK:\u003c\/strong\u003e Fine for most industrial applications under 500 psi.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh pressure need:\u003c\/strong\u003e Request custom pressure test service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTemperature Limits at a Glance\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMinimum continuous:\u003c\/strong\u003e -52°C (-62°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum continuous:\u003c\/strong\u003e +177°C (+350°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSeal warning:\u003c\/strong\u003e Below -34°C, Viton may crack.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShort term exposure:\u003c\/strong\u003e Tip can reach +218°C (+425°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable limit:\u003c\/strong\u003e +260°C (+500°F) for extended range version.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard version:\u003c\/strong\u003e Suits 95% of industrial machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTemperature Class Selection Table\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGas zone T1:\u003c\/strong\u003e Max surface 232°C, ambient -55 to +232°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGas zone T2:\u003c\/strong\u003e Max surface 177°C, ambient -55 to +177°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGas zone T3:\u003c\/strong\u003e Max surface 120°C, ambient -55 to +120°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGas zone T4:\u003c\/strong\u003e Max surface 80°C, ambient -55 to +80°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGas zone T5:\u003c\/strong\u003e Max surface 40°C, ambient -55 to +40°C.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDust zone:\u003c\/strong\u003e Surface limits from 280°C down to 90°C depending on ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Notes for Short Probe\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWrench size:\u003c\/strong\u003e 7\/8 inch open end.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTorque:\u003c\/strong\u003e 15-20 Nm (11-15 lb-ft).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGap setting:\u003c\/strong\u003e 1.5mm (60 mils) from shaft.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMethod:\u003c\/strong\u003e Touch shaft, back off 1.5 turns.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLock nut:\u003c\/strong\u003e Tighten against mounting surface.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAccess tip:\u003c\/strong\u003e Short probe fits where wrench swing is limited.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatibility Check\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProximitor:\u003c\/strong\u003e 3300 XL 8mm (330180-90-00) required.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtension cables:\u003c\/strong\u003e Use 3300 XL series only.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum total length:\u003c\/strong\u003e Probe + extension = proximitor rating.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExample:\u003c\/strong\u003e 0.5m probe + 4.5m extension = 5.0m system.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Standard 3300 XL coaxial.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTarget:\u003c\/strong\u003e Calibrated for AISI 4140 steel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIncluded in Package\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe:\u003c\/strong\u003e \u003cstrong\u003e330192-00-28-05-00\u003c\/strong\u003e with attached 0.5m armored cable.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLock nut:\u003c\/strong\u003e 3\/8-24 UNF hex nut.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCalibration certificate:\u003c\/strong\u003e Individual sensitivity data.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInstruction sheet:\u003c\/strong\u003e Short form installation guide.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProtector cap:\u003c\/strong\u003e For connector storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Details\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg (0.66 lb).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Small cardboard tube.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTube size:\u003c\/strong\u003e 30 x 30 x 200 mm.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping carriers:\u003c\/strong\u003e FedEx, UPS, DHL.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDelivery:\u003c\/strong\u003e 2-5 business days worldwide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum wall thickness for this 2.8 inch probe?\u003c\/strong\u003e\u003cbr\u003e\n    A: Safe maximum is 2.0 inches (50mm). Calculation: 2.8in case minus 0.5in minimum thread engagement minus 0.06in gap minus 0.24in safety margin = 2.0in maximum wall. Thicker walls risk the tip not reaching the shaft.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: Why would I choose 0.5 meter cable over longer options?\u003c\/strong\u003e\u003cbr\u003e\n    A: Short cable keeps resistance low and signal strong. It also reduces cost and weight. Use 0.5m when your proximitor mounts very close to the probe, such as on the same machine skid or inside a local junction box.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: Can I add extension cable to reach 5.0 meters total?\u003c\/strong\u003e\u003cbr\u003e\n    A: Yes. Add a 4.5 meter 3300 XL extension cable. The system total becomes 0.5m + 4.5m = 5.0m. Verify your proximitor label shows 5.0m calibration. Do not exceed the printed length.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: Is zero unthreaded length a problem for sealing?\u003c\/strong\u003e\u003cbr\u003e\n    A: Not if you use proper thread sealant. Without a smooth unthreaded section, you cannot use a copper crush washer. Apply PTFE tape (3 to 5 wraps) or anaerobic pipe sealant to the threads. The sealant prevents leakage through thread paths.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What tools do I need to install this short probe?\u003c\/strong\u003e\u003cbr\u003e\n    A: You need a 7\/8 inch open-end wrench for the hex flats. A 3\/8-24 UNF tap to clean mounting threads. A gap setting tool or feeler gauge. No special tools required - standard mechanic's tools work.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47618764374274,"sku":"330192-00-28-05-00","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/330192-00-28-05-00.jpg?v=1775202848","url":"https:\/\/www.nex-auto.com\/products\/bently-nevada-330192-00-28-05-00-short-probe","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}