{"product_id":"bently-nevada-83387-065-hardline-cable-65in","title":"Bently Nevada 83387-065 Hardline Cable 65in","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 83387-065\u003c\/strong\u003e 65 Inch Hardline Cable\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong\u003e83387-065\u003c\/strong\u003e Hardline cable\u003c\/span\u003e for accelerometer interface modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Mineral insulated Hardline cable with stainless steel overbraid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 65 inches (5.4 feet \/ 1.65 meters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New \u0026amp; original in factory packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months factory warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e83387-065 vs 83387-054\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e83387-065:\u003c\/strong\u003e 65 inches (5.4 feet) - longer reach.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e83387-054:\u003c\/strong\u003e 54 inches (4.5 feet) - shorter reach.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame construction:\u003c\/strong\u003e Both use mineral insulation and stainless overbraid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame temperature ratings:\u003c\/strong\u003e Identical -54°C to +649°C capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame connectors:\u003c\/strong\u003e Both use MS 3100R-10SL-4P and MS 3106-10SL-4S.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose 065 when:\u003c\/strong\u003e Extra 11 inches of reach needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLength Selection Guide\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Hardline lengths:\u003c\/strong\u003e 012 (12in), 024 (24in), 036 (36in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedium lengths:\u003c\/strong\u003e 048 (48in), 054 (54in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThis length:\u003c\/strong\u003e 065 (65in) - 5.4 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger options:\u003c\/strong\u003e 072 (72in), 084 (84in), 096 (96in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelection rule:\u003c\/strong\u003e Shortest length that reaches - minimizes signal loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom lengths:\u003c\/strong\u003e Available for special requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHardline Temperature Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable continuous:\u003c\/strong\u003e -54°C to +649°C (-65°F to +1200°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccelerometer connector:\u003c\/strong\u003e -54°C to +427°C (-65°F to +800°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect interface connector:\u003c\/strong\u003e -54°C to +427°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftline limit:\u003c\/strong\u003e Only +204°C at cable, +93°C at interface connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardline advantage:\u003c\/strong\u003e 445°C higher temperature capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas turbines, furnaces, kilns, exhaust monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStainless Steel Overbraid Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Braided AISI 304 stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage:\u003c\/strong\u003e Approximately 90-95% braid density.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensile strength:\u003c\/strong\u003e Withstands pulling during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrush resistance:\u003c\/strong\u003e Protects mineral core from impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbrasion resistance:\u003c\/strong\u003e Rubs against machine parts safely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion resistance:\u003c\/strong\u003e Suitable for outdoor and marine use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConnector Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccelerometer end:\u003c\/strong\u003e MS 3100R-10SL-4P receptacle mating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccelerometer connector feature:\u003c\/strong\u003e Viton insert for high temp sealing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface end:\u003c\/strong\u003e MS 3106-10SL-4S disconnect connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector material:\u003c\/strong\u003e High temperature alloy (not standard aluminum).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact type:\u003c\/strong\u003e Solder or crimp (factory terminated).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey difference from Softline:\u003c\/strong\u003e Hardline uses MS 3106-10SL-4S, not MS 3112-8-3P.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e65 Inch Length Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge gas turbines:\u003c\/strong\u003e Long reach from accelerometer to junction box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial furnaces:\u003c\/strong\u003e Cable routes around hot zones to cool area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor stations:\u003c\/strong\u003e Remote mounting of interface module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine engines:\u003c\/strong\u003e Space constraints require longer cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit projects:\u003c\/strong\u003e Original cable was 65 inches - direct replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest stands:\u003c\/strong\u003e Flexible positioning of data acquisition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact length:\u003c\/strong\u003e 65 inches (1.65 meters) nominal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter diameter:\u003c\/strong\u003e Approximately 7-9mm including overbraid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 0.4 kg (0.88 lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum bend radius:\u003c\/strong\u003e 130mm (5.2 inches) - based on 2x diameter rule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend radius comparison:\u003c\/strong\u003e Less flexible than 54in due to longer length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector size:\u003c\/strong\u003e Standard MS series, approximately 30mm diameter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Tips for 65 Inch Length\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan the route:\u003c\/strong\u003e 65 inches allows moderate routing flexibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport every 12 inches:\u003c\/strong\u003e Use stainless steel cable ties.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-form bends:\u003c\/strong\u003e Gentle curves only - no sharp bends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum bend radius:\u003c\/strong\u003e 130mm (5.2 inches) strictly observed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeave service loop:\u003c\/strong\u003e Extra 2-3 inches at each end.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid tension:\u003c\/strong\u003e Cable should not pull on connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility Check\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccelerometer requirement:\u003c\/strong\u003e Must have MS 3100R-10SL-4P receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface module requirement:\u003c\/strong\u003e Must have MS 3106-10SL-4S connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot compatible with:\u003c\/strong\u003e Modules using MS 3112-8-3P (Softline type).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdapter available:\u003c\/strong\u003e May need adapter between Hardline and Softline modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify before ordering:\u003c\/strong\u003e Check your module connector part number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon mistake:\u003c\/strong\u003e Assuming all Bently accelerometer cables interchange.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 0.6 kg (1.3 lb) packaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Sealed moisture barrier bag in cardboard box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBox dimensions:\u003c\/strong\u003e 25 x 25 x 10 cm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFedEx:\u003c\/strong\u003e 2-3 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPS:\u003c\/strong\u003e 2-4 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDHL:\u003c\/strong\u003e 3-5 business days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the exact length of 83387-065 in meters?\u003c\/strong\u003e\u003cbr\u003eA: 65 inches equals 1.651 meters (5.42 feet). Bently Nevada specifies Hardline cables in inches, unlike Softline cables which use meters. This matches legacy installation drawings that use imperial units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use 83387-065 with a Softline interface module?\u003c\/strong\u003e\u003cbr\u003eA: No, because the connectors are different. Hardline uses MS 3106-10SL-4S. Softline modules use MS 3112-8-3P. You need an adapter cable or replace the module connector. Contact Bently for adapter part numbers if you must mix systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Why would I choose 65 inches over 54 inches?\u003c\/strong\u003e\u003cbr\u003eA: Choose 65 inches when your accelerometer to interface module distance exceeds 54 inches. Extra 11 inches matters in large machinery. However, longer cables have higher signal attenuation and cost more. Always use the shortest length that reaches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I store spare 83387-065 cables?\u003c\/strong\u003e\u003cbr\u003eA: Keep in original sealed moisture barrier bag with desiccant. Do not open until ready to install. Mineral insulation absorbs humidity from air. Opened but unused cables should be resealed or stored in a dry nitrogen cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum temperature at the connector end?\u003c\/strong\u003e\u003cbr\u003eA: Both connectors are rated to +427°C (+800°F) continuous. This is the system limit even though the cable itself handles +649°C. If your application exceeds +427°C at the connector, you must relocate the connection point to a cooler area.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47631170273538,"sku":"83387-065","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/83387-065.jpg?v=1775618553","url":"https:\/\/www.nex-auto.com\/products\/bently-nevada-83387-065-hardline-cable-65in","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}