{"product_id":"dfe32b-sew-profinet-io-fieldbus-interface","title":"DFE32B SEW PROFINET IO Fieldbus Interface","description":"\u003ch2\u003e\u003cstrong\u003eDFE32B SEW PROFINET IO Fieldbus Interface for MOVIDRIVE MDX61B\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e SEW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eDFE32B\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e PROFINET IO Fieldbus Interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e \u003cstrong\u003eDFE32B\u003c\/strong\u003e (18213456)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for MOVIDRIVE MDX61B units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Name for Project Planning:\u003c\/strong\u003e MOVIDRIVE DFE32B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Real-time data exchange between a controller and a drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Supply:\u003c\/strong\u003e DC 24 V (–15 %, +20 %)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Data Set:\u003c\/strong\u003e Index 47\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Slot Number:\u003c\/strong\u003e Recommended 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Code:\u003c\/strong\u003e 10A hex (SEW-EURODRIVE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfile ID:\u003c\/strong\u003e 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC2 Response Timeout:\u003c\/strong\u003e 1 S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Length C1 Channel:\u003c\/strong\u003e 240 bytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Length C2 Channel:\u003c\/strong\u003e 240 bytes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference Immunity:\u003c\/strong\u003e Robust gateway design keeps communication stable in industrial networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 0.6 cm x 12.7 cm x 7.6 cm (0.3\" x 5.0\" x 3.0\")\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.44 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003ePROFINET IO\u003c\/strong\u003e\u003c\/span\u003e protocol delivers real-time communication between controller and drive.\u003c\/li\u003e\n\u003cli\u003eEach C1 and C2 channel carries up to \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e240 bytes\u003c\/strong\u003e\u003c\/span\u003e for flexible data mapping.\u003c\/li\u003e\n\u003cli\u003eThe module draws only 3 W, so it adds little load to the 24 VDC supply.\u003c\/li\u003e\n\u003cli\u003eWide voltage tolerance of –15 % to +20 % keeps the card stable on noisy grids.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer code 10A hex supports quick project setup in SEW software.\u003c\/li\u003e\n\u003cli\u003eA compact 0.44 kg gateway fits easily inside the MDX61B cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the MOVIDRIVE MDX61B unit and disconnect all supply lines first.\u003c\/li\u003e\n\u003cli\u003eFind the fieldbus option slot inside the MDX61B housing.\u003c\/li\u003e\n\u003cli\u003eAlign the \u003cstrong\u003eDFE32B\u003c\/strong\u003e module with the slot rails and slide it in firmly.\u003c\/li\u003e\n\u003cli\u003eSecure the module with the mounting screw from the accessory kit.\u003c\/li\u003e\n\u003cli\u003eConnect the DC 24 V supply and confirm the polarity before power-up.\u003c\/li\u003e\n\u003cli\u003eAttach the PROFINET cable to the gateway port on the module.\u003c\/li\u003e\n\u003cli\u003eSet the module name to MOVIDRIVE DFE32B and use slot number 0 in the project.\u003c\/li\u003e\n\u003cli\u003eUse data set index 47 and keep the C1 and C2 channels within 240 bytes each.\u003c\/li\u003e\n\u003cli\u003ePower up the drive and check the PROFINET connection in the controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eDFE32B\u003c\/strong\u003e PROFINET IO fieldbus interface\u003c\/li\u003e\n\u003cli\u003eOne mounting screw set\u003c\/li\u003e\n\u003cli\u003eOne quick reference installation sheet\u003c\/li\u003e\n\u003cli\u003eProtective anti-static packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide through FedEx, UPS and DHL.\u003c\/li\u003e\n\u003cli\u003eWe dispatch in-stock items within 5 business days.\u003c\/li\u003e\n\u003cli\u003eWe accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003cli\u003eOur team answers technical questions about the \u003cstrong\u003eDFE32B\u003c\/strong\u003e and MDX61B series promptly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What protocol does the DFE32B use?\u003c\/strong\u003e\u003cbr\u003eA: It uses PROFINET IO for real-time communication between a controller and a drive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power supply does the module need?\u003c\/strong\u003e\u003cbr\u003eA: The DFE32B runs on DC 24 V with –15 % to +20 % tolerance and draws about 3 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What are the maximum channel lengths?\u003c\/strong\u003e\u003cbr\u003eA: Both the C1 and C2 channels support up to 240 bytes each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What module name should I use in project planning?\u003c\/strong\u003e\u003cbr\u003eA: Use the name MOVIDRIVE DFE32B with recommended slot number 0.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the supported data set index?\u003c\/strong\u003e\u003cbr\u003eA: The module supports data set index 47.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this card compatible with MOVIDRIVE MDX61B units only?\u003c\/strong\u003e\u003cbr\u003eA: Yes, SEW designed the DFE32B specifically for the MOVIDRIVE MDX61B drive family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the item new and in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we offer brand new original units and hold stock for fast dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast do you ship, and which carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship within 5 days via FedEx, UPS and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SEW","offers":[{"title":"Default Title","offer_id":51169236451586,"sku":"DFE32B","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/DFE32B-2.jpg?v=1795402014","url":"https:\/\/www.nex-auto.com\/products\/dfe32b-sew-profinet-io-fieldbus-interface","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}