{"product_id":"ge-400w-power-supply-is2020rkpsg2a","title":"GE 400W Power Supply IS2020RKPSG2A","description":"\u003ch2\u003e\u003cstrong\u003eReliable VME Rack Power for Turbine Control Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Electric\u003c\/strong\u003e engineered the \u003cstrong\u003eIS2020RKPSG2A\u003c\/strong\u003e for robust power delivery. This VME Rack Power Supply Module operates within \u003cstrong\u003eMark VI\u003c\/strong\u003e Speedtronic systems. It provides stable, regulated DC power to VME control and interface racks in gas turbine applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e\u003c\/span\u003e General Electric \u003cstrong\u003eIS2020RKPSG2A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e VME Rack Power Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003c\/span\u003e Mark VI Speedtronic System\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003c\/span\u003e 125 VDC from Power Distribution Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTotal Output Power:\u003c\/strong\u003e\u003c\/span\u003e 400 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eBoard Size:\u003c\/strong\u003e\u003c\/span\u003e 6.25 × 4.25 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/span\u003e 7 lbs (3.18 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eOutput Voltage Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e+5 VDC for logic and processor circuits\u003c\/li\u003e\n\u003cli\u003e±12 VDC for analog signal processing\u003c\/li\u003e\n\u003cli\u003e±15 VDC for precision analog applications\u003c\/li\u003e\n\u003cli\u003e±28 VDC for probe excitation and remote devices\u003c\/li\u003e\n\u003cli\u003eFive +28V outputs power VME rack sections A-F\u003c\/li\u003e\n\u003cli\u003eOne remote +28V output (P28C\/PS28) for external peripherals\u003c\/li\u003e\n\u003cli\u003eOptional 335 VDC output for TRPG flame detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInput Voltage Options\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eStandard 125 VDC:\u003c\/strong\u003e\u003c\/span\u003e Powered by Power Distribution Module (PDM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eLow Voltage Version:\u003c\/strong\u003e\u003c\/span\u003e 24 VDC operation available (LVPSG2)\u003c\/li\u003e\n\u003cli\u003eDirect replacement for RKPSG1 and LVPSG1 respectively\u003c\/li\u003e\n\u003cli\u003eFlexible configuration for different system requirements\u003c\/li\u003e\n\u003cli\u003eReliable power source for turbine control applications\u003c\/li\u003e\n\u003cli\u003eProven performance in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFront Panel Controls \u0026amp; Indicators\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSingle user control: locking power switch with pull-to-toggle operation\u003c\/li\u003e\n\u003cli\u003eLow voltage control for enabling\/disabling output voltages\u003c\/li\u003e\n\u003cli\u003eServes as fault reset when toggled off and on\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eGreen LED:\u003c\/strong\u003e\u003c\/span\u003e Normal operation indicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eYellow LED:\u003c\/strong\u003e\u003c\/span\u003e Input power status\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eRed LED:\u003c\/strong\u003e\u003c\/span\u003e Fault condition presence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Configuration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStand-alone module design for VME rack mounting\u003c\/li\u003e\n\u003cli\u003eMounts on right-hand side of VME rack via sheet metal bracket\u003c\/li\u003e\n\u003cli\u003eLarge heat sink with metal fins for thermal management\u003c\/li\u003e\n\u003cli\u003eFront faceplate labeled \"Power supply\" with revision, catalog, and serial numbers\u003c\/li\u003e\n\u003cli\u003eTop edge: PSA and PSB connectors for VME rack power harness\u003c\/li\u003e\n\u003cli\u003eBottom edge: PS125, PS335, PS28, and PSSTAT connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eConnector Layout\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePSA\/PSB (Top):\u003c\/strong\u003e\u003c\/span\u003e Mate with cable harness to VME rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePS125\/PS24:\u003c\/strong\u003e\u003c\/span\u003e DC input power connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePS335:\u003c\/strong\u003e\u003c\/span\u003e Optional flame detector power output\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePS28:\u003c\/strong\u003e\u003c\/span\u003e 28 VDC outputs for rack sections and remote device\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePSSTAT:\u003c\/strong\u003e\u003c\/span\u003e Status connector for diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eAll bottom connections easily accessible for installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e5V Current Limit Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpecial case handling due to 5V under-voltage detector\u003c\/li\u003e\n\u003cli\u003eCurrent limit causes 5V output to fold back below UV threshold\u003c\/li\u003e\n\u003cli\u003eAll other outputs automatically disable during fault\u003c\/li\u003e\n\u003cli\u003eOutputs restore when 5V returns above UV threshold\u003c\/li\u003e\n\u003cli\u003eProtects downstream components from undervoltage conditions\u003c\/li\u003e\n\u003cli\u003eEnsures system integrity during power disturbances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFault Management\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree fault response types: reset required, transient output shutdown, or supply replacement\u003c\/li\u003e\n\u003cli\u003eFaults cleared by toggling power switch off then on\u003c\/li\u003e\n\u003cli\u003eFault cleared only if root cause no longer exists\u003c\/li\u003e\n\u003cli\u003eRed LED indicates active fault condition\u003c\/li\u003e\n\u003cli\u003eSimple fault recovery procedure for operators\u003c\/li\u003e\n\u003cli\u003eMinimal system downtime during fault resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExternal Peripheral Power Configuration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eP28C or PS28 output at bottom powers external devices\u003c\/li\u003e\n\u003cli\u003eJumper plug on bracket left of rack selects configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eNormal Position:\u003c\/strong\u003e\u003c\/span\u003e Standard rack power operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eIsolated Position:\u003c\/strong\u003e\u003c\/span\u003e Enables external peripheral power\u003c\/li\u003e\n\u003cli\u003eFlexible power distribution for auxiliary equipment\u003c\/li\u003e\n\u003cli\u003eSimple jumper adjustment for configuration changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for Mark VI VME control and interface racks\u003c\/li\u003e\n\u003cli\u003eSupports redundant operation for critical applications\u003c\/li\u003e\n\u003cli\u003eCompatible with gas, steam, and wind turbine systems\u003c\/li\u003e\n\u003cli\u003eIncorporates Speedtronic control system technology\u003c\/li\u003e\n\u003cli\u003eGroup 2 Mark VI Series product grouping\u003c\/li\u003e\n\u003cli\u003eNormal PCB coating for environmental protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Availability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eCurrent Status:\u003c\/strong\u003e\u003c\/span\u003e In stock for immediate shipment\u003c\/li\u003e\n\u003cli\u003eNew and original General Electric component\u003c\/li\u003e\n\u003cli\u003eA-rated primary functional product revision\u003c\/li\u003e\n\u003cli\u003eManufactured in the United States\u003c\/li\u003e\n\u003cli\u003eComplete with installation documentation\u003c\/li\u003e\n\u003cli\u003eReference manual: GEH-6421E and GEI-100567\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine VME rack power distribution\u003c\/li\u003e\n\u003cli\u003eSteam turbine control system power supply\u003c\/li\u003e\n\u003cli\u003eWind turbine automated drive assemblies\u003c\/li\u003e\n\u003cli\u003eTRPG flame detector power for gas turbines\u003c\/li\u003e\n\u003cli\u003eVME backplane power for I\/O and processor boards\u003c\/li\u003e\n\u003cli\u003eExternal peripheral device power applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount to right-hand side of VME rack using sheet metal bracket\u003c\/li\u003e\n\u003cli\u003eConnect DC input to PS125\/PS24 at bottom\u003c\/li\u003e\n\u003cli\u003eMate PSA\/PSB connectors with VME rack cable harness\u003c\/li\u003e\n\u003cli\u003eConfigure jumper for normal or isolated operation\u003c\/li\u003e\n\u003cli\u003eVerify all connections before power application\u003c\/li\u003e\n\u003cli\u003eFollow GEH-6421E manual for complete instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast shipping via FedEx, UPS, and DHL services\u003c\/li\u003e\n\u003cli\u003eOrders typically ship within 24 business hours\u003c\/li\u003e\n\u003cli\u003eInternational shipping available worldwide\u003c\/li\u003e\n\u003cli\u003eComplete tracking information provided\u003c\/li\u003e\n\u003cli\u003eProfessional packaging ensures module protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat input voltage does this power supply require?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS2020RKPSG2A\u003c\/strong\u003e requires 125 VDC input from a Power Distribution Module. A 24 VDC low voltage version (LVPSG2) is also available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat output voltages are provided?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides +5V, ±12V, ±15V, ±28V DC outputs, plus five +28V rack section outputs and an optional 335V DC output for flame detectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow much total power can it deliver?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTotal output power rating is 400 Watts across all output voltages for reliable system operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow are faults indicated and cleared?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRed LED indicates fault condition. Toggle power switch off then on to clear fault only if root cause no longer exists.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it power external peripheral devices?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYes, the P28C\/PS28 output can power external devices by moving the jumper from Normal to Isolated position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat documentation is available?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRefer to GE manuals GEH-6421E and GEI-100567 for complete technical specifications and installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47357756539138,"sku":"IS2020RKPSG2A","price":402.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS2020RKPSG2A-1.jpg?v=1770865377","url":"https:\/\/www.nex-auto.com\/products\/ge-400w-power-supply-is2020rkpsg2a","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}