{"product_id":"ge-ds200siobh1aba-mark-v-vme-i-o-card","title":"GE DS200SIOBH1ABA Mark V VME I\/O Card","description":"\u003ch2\u003eCore Specifications: GE DS200SIOBH1ABA\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eGeneral Electric DS200SIOBH1ABA\u003c\/strong\u003e — authentic Mark V Speedtronic series board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Industrial Systems (USA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e VME Stand I\/O Card. Functional acronym \u003cstrong\u003eSIOB\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V Turbine Control System. Legacy Speedtronic technology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Description:\u003c\/strong\u003e SC2000 VME I\/O Board. Occupies one full VME slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Protection:\u003c\/strong\u003e Full conformal coating. Group 1 Mark V Series product grouping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision History:\u003c\/strong\u003e Three revisions. Modified version of parent \u003cstrong\u003eDS200SIOBH1\u003c\/strong\u003e board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e Normal assembly. US domestic manufacture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e In stock. Ready to ship.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHardware Configuration \u0026amp; Jumpers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Jumpers:\u003c\/strong\u003e 20 factory-positioned jumpers. Some support only one position. Cannot alter these.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Blocks:\u003c\/strong\u003e Three blocks. Each contains six switches. Total 18 configurable switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Defaults:\u003c\/strong\u003e Jumpers arrive preset from GE. Match original board settings for consistent performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternate Settings:\u003c\/strong\u003e Refer to original printed material. Some jumper positions change board behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Rule:\u003c\/strong\u003e Always match new board jumpers to old board. Ensures identical drive support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40-Pin Connector:\u003c\/strong\u003e One onboard connector. Provides I\/O interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDiagnostic LED Indicator\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle LED:\u003c\/strong\u003e One diagnostic indicator on base circuit board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIllumination Condition:\u003c\/strong\u003e LED glows when VME rack accesses the \u003cstrong\u003eDS200SIOBH1ABA\u003c\/strong\u003e board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Meaning:\u003c\/strong\u003e Indicates normal functional status. Confirms board communication with Mark V system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTroubleshooting Aid:\u003c\/strong\u003e Quick visual confirmation. No software needed for basic operational check.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVME Rack Integration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Location:\u003c\/strong\u003e Installs in VME rack assembly. Connects to VME P1 connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Occupation:\u003c\/strong\u003e Occupies one full VME slot. Standard Mark V form factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Compatibility:\u003c\/strong\u003e Functions alongside other VME modules in Speedtronic control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Retention:\u003c\/strong\u003e Secures with mounting screws. Two-hand removal required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Lineage \u0026amp; Revision Status\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eParent Board:\u003c\/strong\u003e Derived from \u003cstrong\u003eDS200SIOBH1\u003c\/strong\u003e. The ABA variant includes three functional revisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision Impact:\u003c\/strong\u003e Altered performance specifications. Dimensions may differ from original H1 documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation Note:\u003c\/strong\u003e Original manuals describe parent board. ABA revision supersedes those specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Status:\u003c\/strong\u003e Mark V series discontinued. This board remains a critical spare for active turbine installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeedtronic Heritage:\u003c\/strong\u003e Uses patented GE technology dating from Mark I (1960s) through Mark V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Procedure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOld Board Removal:\u003c\/strong\u003e Remove mounting screws. Use two hands. Avoid contact with other drive components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Flatten static protective bag on clean dry surface. Place old board on bag.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNew Board Handling:\u003c\/strong\u003e Slide replacement from sealed bag. Carry with two hands. Place adjacent to old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Matching:\u003c\/strong\u003e Compare jumper positions. Set new board jumpers to match old board exactly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Matching:\u003c\/strong\u003e Configure all three switch blocks. Match each of the 18 switch positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Board will behave identically. Drive performance remains consistent after replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Construction:\u003c\/strong\u003e Standard Mark V VME form factor. Conformal coated surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComponent Density:\u003c\/strong\u003e Populated with jumpers, switches, 40-pin connector, and LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Handling:\u003c\/strong\u003e Two-handed carry required. Sensitive components on both sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Bag:\u003c\/strong\u003e Ships in sealed ESD bag. Open only at installation time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping \u0026amp; Availability\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock Status:\u003c\/strong\u003e In stock. Ships within 24 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Anti-static ESD bag. Foam-lined industrial box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat You Receive:\u003c\/strong\u003e 1x \u003cstrong\u003eGE DS200SIOBH1ABA\u003c\/strong\u003e VME Stand I\/O Card. Factory jumper presets. No cables or mounting hardware included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the difference between DS200SIOBH1 and DS200SIOBH1ABA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ABA variant carries three total revisions. The parent H1 board is the original SC2000 VME I\/O Board. The ABA version includes updated performance specifications. Always verify jumper mappings, as ABA revisions may differ from H1 documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How do I determine the correct jumper settings if I lost the old board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou need the original GE manual for your specific turbine application. Factory defaults are preset on the board. However, drive performance may require specific non-default positions. Contact technical support with your Mark V model number for guidance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Which jumpers cannot be changed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGE does not publish a universal list. Some jumpers have only one supported position. Attempting to move these jumpers damages the board or causes unreliable operation. Always assume any jumper not mentioned in your manual is fixed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Does the LED indicate board failure if it turns off?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The LED only glows during VME access. It is not a continuous power indicator. The LED may turn on and off during normal operation. Absence of light does not automatically mean board failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Can I install this board in a Mark VI VME rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. GE designed the \u003cstrong\u003eDS200SIOBH1ABA\u003c\/strong\u003e specifically for Mark V systems. Mark VI uses different backplane architecture and I\/O packs. Physical fit may differ. Electrical compatibility is not guaranteed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. How do I confirm conformal coating presence on this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect under bright light. The coating appears as a thin transparent gloss. It covers traces and component bodies. The Group 1 designation in the product number confirms factory-applied coating. No field application required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Buying advice: Should I choose the ABA revision over available H1 stock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \u003cstrong\u003eDS200SIOBH1ABA\u003c\/strong\u003e includes three revisions absent from the original H1. GE released these revisions to resolve field issues. The ABA variant is the most mature SIOB board for Mark V systems. For legacy turbine support, ABA is the preferred spare.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. Why does the installation procedure emphasize two-handed handling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVME boards are long and component-heavy. One-handed carry risks flexing the PCB. Flexing cracks solder joints and damages surface mount components. Two hands distribute support evenly. This rule prevents hidden mechanical damage.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47358141694210,"sku":"DS200SIOBH1ABA","price":596.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/DS200SIOBH1ABA-1.jpg?v=1770885272","url":"https:\/\/www.nex-auto.com\/products\/ge-ds200siobh1aba-mark-v-vme-i-o-card","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}