{"product_id":"ge-is200eacfg2abb-ex2100-exciter-board","title":"GE IS200EACFG2ABB EX2100 Exciter Board","description":"\u003csection\u003e\n  \u003ch2\u003e\u003cstrong\u003eGE IS200EACFG2ABB EX2100 Exciter AC Feedback Board\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cp\u003eThe \u003cstrong\u003eGE IS200EACFG2ABB\u003c\/strong\u003e is an Exciter AC Feedback board from the EX2100 Series manufactured by General Electric. This board monitors and measures exciter PPT AC supply voltage and current within EX2100 Excitation Control systems. It ensures accurate feedback for system stability and efficiency in power generation applications.\u003c\/p\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003eIS200EACFG2ABB\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e EX2100\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Exciter AC Feedback Board\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCountry of Manufacture:\u003c\/strong\u003e United States (USA)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage Measurement:\u003c\/strong\u003e Three-phase PPT AC supply via integrated transformers\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCurrent Measurement:\u003c\/strong\u003e Via flux\/air core coils connected to TB4\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutput Connectors:\u003c\/strong\u003e 3 DB9 connectors for controllers M1, M2, and C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Cable Length:\u003c\/strong\u003e 90 meters between EACF board and EBKP backplane\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInput Terminals:\u003c\/strong\u003e TB1, TB2, TB3 for voltage wiring; TB4 for coil inputs\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secured with 3 screws to mounting standoffs\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eIntegrated transformers for precise three-phase voltage measurement\u003c\/li\u003e\n    \u003cli\u003eDedicated TB4 terminals for flux\/air core coil current sensing\u003c\/li\u003e\n    \u003cli\u003eThree DB9 outputs distribute signals to redundant controllers\u003c\/li\u003e\n    \u003cli\u003eSupports cable runs up to 90 meters for flexible installation\u003c\/li\u003e\n    \u003cli\u003eCritical feedback component for EX2100 excitation stability\u003c\/li\u003e\n    \u003cli\u003eDirect replacement for existing EACF boards in EX2100 systems\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eMeasurement Capabilities\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage Inputs:\u003c\/strong\u003e Three-phase PPT AC supply via TB1, TB2, TB3\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCurrent Inputs:\u003c\/strong\u003e Flux\/air core coil connections at TB4\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutput Distribution:\u003c\/strong\u003e Processed signals to M1, M2, and C controllers via DB9\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFeedback Accuracy:\u003c\/strong\u003e Ensures precise excitation control loop performance\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eInstallation Procedure\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eOpen auxiliary cabinet and verify circuit is fully de-energized using voltage tester\u003c\/li\u003e\n    \u003cli\u003eLabel all cables with connector names as marked on board before disconnecting\u003c\/li\u003e\n    \u003cli\u003eDisconnect voltage wiring from TB1, TB2, TB3 and coil wiring from TB4\u003c\/li\u003e\n    \u003cli\u003eRemove 3 screws securing board to mounting standoffs\u003c\/li\u003e\n    \u003cli\u003eGently extract existing board without damaging adjacent components\u003c\/li\u003e\n    \u003cli\u003ePosition new \u003cstrong\u003eIS200EACFG2ABB\u003c\/strong\u003e in same orientation\u003c\/li\u003e\n    \u003cli\u003eSecure with 3 screws to proper torque specification\u003c\/li\u003e\n    \u003cli\u003eReconnect all labeled cables to correct terminals\u003c\/li\u003e\n    \u003cli\u003eVerify connections at both ends before restoring power\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e1x \u003cstrong\u003eGE IS200EACFG2ABB\u003c\/strong\u003e Exciter AC Feedback Board\u003c\/li\u003e\n    \u003cli\u003eAnti-static protective packaging\u003c\/li\u003e\n    \u003cli\u003eShips via FedEx, UPS, or DHL\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is the function of this board?\u003c\/strong\u003e\u003cbr\u003eIt measures exciter PPT AC voltage and current, providing feedback to EX2100 controllers for excitation system stability.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat voltage and current inputs does it support?\u003c\/strong\u003e\u003cbr\u003eThree-phase voltage via TB1-3 and flux\/air core coil current via TB4.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHow does it connect to controllers?\u003c\/strong\u003e\u003cbr\u003eThree DB9 connectors distribute measured signals to M1, M2, and C controllers.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable distance?\u003c\/strong\u003e\u003cbr\u003eUp to 90 meters between EACF board and EBKP backplane.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat precautions should I take during replacement?\u003c\/strong\u003e\u003cbr\u003eVerify zero voltage, label all cables, and ensure proper reseating of connections.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47410919604482,"sku":"IS200EACFG2ABB","price":884.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS200EACFG2ABB.jpg?v=1772094033","url":"https:\/\/www.nex-auto.com\/products\/ge-is200eacfg2abb-ex2100-exciter-board","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}