{"product_id":"ge-is200ggxig1afe-mark-vi-expander-load-board","title":"GE IS200GGXIG1AFE Mark VI Expander Load Board","description":"\u003csection\u003e\n\u003ch2\u003e\u003cstrong\u003eGE IS200GGXIG1AFE Mark VI Expander Load Source Board\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200GGXIG1AFE\u003c\/strong\u003e is an Expander Load Source Board for Mark VI Speedtronic systems. This board provides control and isolation between high-voltage power bridges and other cards in Innovation Series racks, converting RS422 signals to fiber-optic for IGCT switching.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003eIS200GGXIG1AFE\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VI \/ Mark VI Speedtronic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Expander Load Source Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e Normal Assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Location:\u003c\/strong\u003e Domestic (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Manufacture:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevisions:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Configuration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable in Triple Redundant or Simplex form\u003c\/li\u003e\n\u003cli\u003eCentral Control Module for system control, monitoring, and protection\u003c\/li\u003e\n\u003cli\u003eConnects to up to 12 power devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Functions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControl and isolation between high-voltage power bridge and board rack cards\u003c\/li\u003e\n\u003cli\u003eConverts RS422 signals to fiber-optic signals\u003c\/li\u003e\n\u003cli\u003eGates bridge IGCT switching devices\u003c\/li\u003e\n\u003cli\u003eEfficient power management within system\u003c\/li\u003e\n\u003cli\u003eInterfaces with BICI, BPII, and GDPA boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJ1-J4:\u003c\/strong\u003e Power supply inputs for GGXI board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJ10-J12:\u003c\/strong\u003e Power output and feedback connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJ15-J16:\u003c\/strong\u003e Voltage feedback connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJFBK:\u003c\/strong\u003e Connects to BICI board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJGATE:\u003c\/strong\u003e Connects to BPII board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJ5:\u003c\/strong\u003e Monitors control power to GDPA board\u003c\/li\u003e\n\u003cli\u003eFiber-optic connectors for IGCT gating signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eGrounding \u0026amp; Isolation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLCOM grounding stabs:\u003c\/strong\u003e For quiet circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCOM grounding stabs:\u003c\/strong\u003e For noisy circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated serial ID chip:\u003c\/strong\u003e Board identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTest Points \u0026amp; Indicators\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e14 TP test points:\u003c\/strong\u003e For monitoring and troubleshooting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 LEDs:\u003c\/strong\u003e Status and fault indication\u003c\/li\u003e\n\u003cli\u003eNo adjustable hardware devices or fuses\u003c\/li\u003e\n\u003cli\u003eCapacitors and resistors for signal conditioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eI\/O Offerings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple I\/Os for connecting with other boards\u003c\/li\u003e\n\u003cli\u003ePower supply inputs for GGXI board\u003c\/li\u003e\n\u003cli\u003ePower output and feedback connectors\u003c\/li\u003e\n\u003cli\u003eVoltage feedback connectors\u003c\/li\u003e\n\u003cli\u003eFiber-optic connections\u003c\/li\u003e\n\u003cli\u003eDedicated communication to BICI, BPII, and GDPA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTriple Redundant or Simplex configuration options\u003c\/li\u003e\n\u003cli\u003eRS422 to fiber-optic signal conversion\u003c\/li\u003e\n\u003cli\u003eControls up to 12 IGCT power devices\u003c\/li\u003e\n\u003cli\u003eIsolation between high-voltage bridge and control cards\u003c\/li\u003e\n\u003cli\u003eDedicated connectors for BICI, BPII, and GDPA\u003c\/li\u003e\n\u003cli\u003eLCOM\/DCOM grounding stabs for noise separation\u003c\/li\u003e\n\u003cli\u003eIsolated serial ID chip for identification\u003c\/li\u003e\n\u003cli\u003e14 test points for diagnostics\u003c\/li\u003e\n\u003cli\u003e9 status LEDs\u003c\/li\u003e\n\u003cli\u003eNo fuses or adjustable hardware\u003c\/li\u003e\n\u003cli\u003eDomestic US manufacture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCompatible Boards\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBICI:\u003c\/strong\u003e Bridge Interface Control Board (via JFBK)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBPII:\u003c\/strong\u003e Bridge Personality Interface Board (via JGATE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGDPA:\u003c\/strong\u003e Gate Driver Power Assembly (monitored via J5)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGGXI:\u003c\/strong\u003e Power supply via J1-J4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStore in anti-static bags or boxes\u003c\/li\u003e\n\u003cli\u003eUse wrist grounding strap when handling\u003c\/li\u003e\n\u003cli\u003ePower off before removal\u003c\/li\u003e\n\u003cli\u003eRemove 7 mounting screws after power off\u003c\/li\u003e\n\u003cli\u003eMatch star washers with appropriate metal standoffs\u003c\/li\u003e\n\u003cli\u003eFollow precautions due to surface voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x \u003cstrong\u003eGE IS200GGXIG1AFE\u003c\/strong\u003e Expander Load Source Board\u003c\/li\u003e\n\u003cli\u003eAnti-static protective packaging\u003c\/li\u003e\n\u003cli\u003eShips via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the function of this board?\u003c\/strong\u003e\u003cbr\u003eIt provides control and isolation between high-voltage power bridges and rack cards, converting RS422 to fiber-optic for IGCT gating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many power devices can it connect to?\u003c\/strong\u003e\u003cbr\u003eUp to 12 IGCT switching devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat connectors are available?\u003c\/strong\u003e\u003cbr\u003eJ1-J4 (GGXI power), J10-J12 (output\/feedback), J15-J16 (voltage feedback), JFBK (BICI), JGATE (BPII), J5 (GDPA monitor), and fiber-optic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many test points and LEDs?\u003c\/strong\u003e\u003cbr\u003e14 TP test points and 9 status LEDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat grounding stabs are included?\u003c\/strong\u003e\u003cbr\u003eLCOM for quiet circuits, DCOM for noisy circuits.\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47415354884354,"sku":"IS200GGXIG1AFE","price":906.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS200GGXIG1AFE.jpg?v=1772176432","url":"https:\/\/www.nex-auto.com\/products\/ge-is200ggxig1afe-mark-vi-expander-load-board","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}