{"product_id":"ge-is200trtdh1ccc-rtd-terminal-board-mark-vi","title":"GE IS200TRTDH1CCC RTD Terminal Board Mark VI","description":"\u003ch2\u003e\u003cstrong\u003ePrecise Temperature Measurement for Industrial Control\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Electric\u003c\/strong\u003e manufactured the \u003cstrong\u003eIS200TRTDH1CCC\u003c\/strong\u003e for accurate temperature monitoring. This RTD Terminal Board operates within \u003cstrong\u003eMark VI\u003c\/strong\u003e control systems. It provides reliable interface for multiple resistance temperature detectors in industrial applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e\u003c\/span\u003e General Electric \u003cstrong\u003eIS200TRTDH1CCC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e Resistance Temperature Device (RTD) Terminal Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003c\/span\u003e Mark VI Control System\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003c\/span\u003e 16 three-wire RTD inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eVoltage Span:\u003c\/strong\u003e\u003c\/span\u003e 0.3532 to 4.054 Volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e\u003c\/span\u003e United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eRTD Compatibility \u0026amp; Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePlatinum RTDs:\u003c\/strong\u003e\u003c\/span\u003e 10Ω, 100Ω, 200Ω platinum sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eCopper RTDs:\u003c\/strong\u003e\u003c\/span\u003e 10Ω copper temperature sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eNickel RTDs:\u003c\/strong\u003e\u003c\/span\u003e 120Ω nickel resistance detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eMaximum Lead Resistance:\u003c\/strong\u003e\u003c\/span\u003e 15Ω (including cable resistance)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eChannel Capacity:\u003c\/strong\u003e\u003c\/span\u003e Eight channels per terminal board\u003c\/li\u003e\n\u003cli\u003eSurface mount technology for reliable connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eHardware Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSixteen three-wire RTD inputs with organized wiring\u003c\/li\u003e\n\u003cli\u003eTwo barrier-type terminal blocks for secure connections\u003c\/li\u003e\n\u003cli\u003eAdvanced noise suppression circuitry on all inputs\u003c\/li\u003e\n\u003cli\u003eProtection against voltage surges and high-frequency noise\u003c\/li\u003e\n\u003cli\u003eTwo DC-type connectors for VRTD simplex operation\u003c\/li\u003e\n\u003cli\u003eShield terminal strip adjacent to each terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation \u0026amp; Wiring\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDirect wiring of 16 RTDs to two terminal blocks\u003c\/li\u003e\n\u003cli\u003eEach terminal block secured with two screws for stability\u003c\/li\u003e\n\u003cli\u003e24 terminals per block accept up to #12 AWG wire\u003c\/li\u003e\n\u003cli\u003eShield terminal strips attached to chassis ground\u003c\/li\u003e\n\u003cli\u003eStrategic placement for efficient grounding\u003c\/li\u003e\n\u003cli\u003eMinimizes electromagnetic interference risks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBoard Variants \u0026amp; Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTRTDH1B:\u003c\/strong\u003e\u003c\/span\u003e TMR variant with six DC connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTRTDH1C:\u003c\/strong\u003e\u003c\/span\u003e Simplex board with two VRTD connectors (this model)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTRTDH1D:\u003c\/strong\u003e\u003c\/span\u003e Simplex with two PRTD normal scan connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTRTDH2D:\u003c\/strong\u003e\u003c\/span\u003e Simplex with two PRTD quick-scan connectors\u003c\/li\u003e\n\u003cli\u003eCommunicates with one or more I\/O processors\u003c\/li\u003e\n\u003cli\u003eConverts analog RTD inputs to digital temperature values\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFault Detection \u0026amp; Safety\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHardware-level high\/low limit checks for out-of-range conditions\u003c\/li\u003e\n\u003cli\u003eSoftware-level limit checks for additional protection\u003c\/li\u003e\n\u003cli\u003eFailed ID chip detection for component monitoring\u003c\/li\u003e\n\u003cli\u003eTrigger appropriate responses to system abnormalities\u003c\/li\u003e\n\u003cli\u003eEnhances system safety and operational reliability\u003c\/li\u003e\n\u003cli\u003eQuick identification and resolution of potential issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSignal Processing \u0026amp; Communication\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O processors convert analog signals to digital values\u003c\/li\u003e\n\u003cli\u003eDigital temperature values transferred to system controller\u003c\/li\u003e\n\u003cli\u003eEnables swift decision-making based on accurate data\u003c\/li\u003e\n\u003cli\u003eMaintains precision and consistency in temperature monitoring\u003c\/li\u003e\n\u003cli\u003eSupports various industrial and scientific applications\u003c\/li\u003e\n\u003cli\u003eEnsures reliable performance in temperature-sensitive systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Availability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eCurrent Status:\u003c\/strong\u003e\u003c\/span\u003e In stock for immediate shipment\u003c\/li\u003e\n\u003cli\u003eNew and original General Electric component\u003c\/li\u003e\n\u003cli\u003eComplete with all necessary hardware and terminals\u003c\/li\u003e\n\u003cli\u003eShips in protective packaging with documentation\u003c\/li\u003e\n\u003cli\u003eReady for integration into temperature monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial process temperature monitoring\u003c\/li\u003e\n\u003cli\u003eEquipment temperature protection systems\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring and control\u003c\/li\u003e\n\u003cli\u003eHVAC system temperature regulation\u003c\/li\u003e\n\u003cli\u003eManufacturing process temperature control\u003c\/li\u003e\n\u003cli\u003eScientific research temperature measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast shipping via FedEx, UPS, and DHL services\u003c\/li\u003e\n\u003cli\u003eOrders typically ship within 24 business hours\u003c\/li\u003e\n\u003cli\u003eInternational shipping available worldwide\u003c\/li\u003e\n\u003cli\u003eComplete tracking information provided\u003c\/li\u003e\n\u003cli\u003eProfessional packaging ensures board protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDesign Advantages\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStreamlined and organized connection process\u003c\/li\u003e\n\u003cli\u003eEffective noise suppression for accurate measurements\u003c\/li\u003e\n\u003cli\u003eVersatile compatibility with multiple RTD types\u003c\/li\u003e\n\u003cli\u003eRobust construction for industrial environments\u003c\/li\u003e\n\u003cli\u003eEasy maintenance and troubleshooting capabilities\u003c\/li\u003e\n\u003cli\u003eReliable long-term performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many RTD inputs does this board support?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS200TRTDH1CCC\u003c\/strong\u003e supports 16 three-wire RTD inputs for comprehensive temperature monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat RTD types are compatible?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 10Ω, 100Ω, 200Ω platinum; 10Ω copper; and 120Ω nickel RTDs for various applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the voltage measurement range?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe board measures RTD signals spanning from 0.3532 to 4.054 Volts for accurate temperature conversion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat protection features are included?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes noise suppression circuitry and surge protection to maintain measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow is the board configured?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis is a simplex board variant (TRTDH1C) with two DC-type connectors for VRTD applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat wire sizes can be used?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTerminal blocks accept wires up to #12 AWG and include shield terminals for proper grounding.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47350035185922,"sku":"IS200TRTDH1CCC","price":665.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS200TRTDH1CCC.jpg?v=1770717424","url":"https:\/\/www.nex-auto.com\/products\/ge-is200trtdh1ccc-rtd-terminal-board-mark-vi","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}