{"product_id":"ge-is200vtcch1cbb-thermocouple-processor-board","title":"GE IS200VTCCH1CBB Thermocouple Processor Board","description":"\u003ch2\u003e\u003cstrong\u003eHigh-Precision Thermocouple Signal Processing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Electric\u003c\/strong\u003e engineered the \u003cstrong\u003eIS200VTCCH1CBB\u003c\/strong\u003e for accurate temperature measurement. This Thermocouple Processor Board operates within \u003cstrong\u003eMark VI\u003c\/strong\u003e Speedtronic systems. It provides reliable processing for multiple thermocouple inputs in turbine control applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e\u003c\/span\u003e General Electric \u003cstrong\u003eIS200VTCCH1CBB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e Thermocouple Processor Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003c\/span\u003e Mark VI Speedtronic System\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003c\/span\u003e 24 thermocouple inputs capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSupported Types:\u003c\/strong\u003e\u003c\/span\u003e E, J, K, S, T thermocouples\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eVoltage Span:\u003c\/strong\u003e\u003c\/span\u003e -8 mV to +45 mV input range\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eA\/D Resolution:\u003c\/strong\u003e\u003c\/span\u003e 16-bit analog-to-digital conversion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProcessing \u0026amp; Conversion Capabilities\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e16-bit analog-to-digital converter for high precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e\u003c\/span\u003e AMD-K6 300 MHz for fast processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eCommon Mode Voltage:\u003c\/strong\u003e\u003c\/span\u003e +5 Volts operational\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eNormal Mode Rejection:\u003c\/strong\u003e\u003c\/span\u003e 250 mV noise rejection\u003c\/li\u003e\n\u003cli\u003eSoftware linearization for individual thermocouple types\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration using filtered reference voltages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Groups\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eVTCCH1 Group:\u003c\/strong\u003e\u003c\/span\u003e Optimized for gas turbine control applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eVTCCH2 Group:\u003c\/strong\u003e\u003c\/span\u003e General purpose with additional thermocouple types\u003c\/li\u003e\n\u003cli\u003eWorks with TBTC or DTTC terminal boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSimplex Control:\u003c\/strong\u003e\u003c\/span\u003e TBTCH1C terminal board configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTMR Control:\u003c\/strong\u003e\u003c\/span\u003e TBTCH1B terminal board configuration\u003c\/li\u003e\n\u003cli\u003eSame terminal boards used with both VTCC groups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eThermocouple Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupports grounded and ungrounded thermocouples\u003c\/li\u003e\n\u003cli\u003eMaximum distance: 300 meters (984 ft) from control cabinet\u003c\/li\u003e\n\u003cli\u003eMaximum cable resistance: 450 Ω (two-way)\u003c\/li\u003e\n\u003cli\u003eHigh-frequency noise suppression on terminal board\u003c\/li\u003e\n\u003cli\u003eTwo cold junction reference devices for accuracy\u003c\/li\u003e\n\u003cli\u003eOut-of-range inputs removed from scanning to protect system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTwo cold junction (CJ) devices for redundancy\u003c\/li\u003e\n\u003cli\u003eAverage of both CJs used when within configurable limits\u003c\/li\u003e\n\u003cli\u003eSingle CJ used when only one within acceptable limits\u003c\/li\u003e\n\u003cli\u003eDefault value applied when neither CJ within limits\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration of thermocouple and CJ inputs\u003c\/li\u003e\n\u003cli\u003eFiltered calibration reference and zero voltage usage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e 8.26 × 4.19 cm (3.25 × 1.65 inches)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTechnology:\u003c\/strong\u003e\u003c\/span\u003e Surface-mount construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e\u003c\/span\u003e United States\u003c\/li\u003e\n\u003cli\u003eDesigned for VME rack installation\u003c\/li\u003e\n\u003cli\u003eCaptive screws for secure front panel mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTMR System Operation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTriple Modular Redundant configuration capability\u003c\/li\u003e\n\u003cli\u003eSignal variance detection from median\/voted values\u003c\/li\u003e\n\u003cli\u003ePredetermined limits for fault identification\u003c\/li\u003e\n\u003cli\u003eFault indication when signals exceed variance limits\u003c\/li\u003e\n\u003cli\u003eDiagnostic checks for system integrity monitoring\u003c\/li\u003e\n\u003cli\u003eComprehensive fault detection capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Procedure\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePower down VME processor rack before installation\u003c\/li\u003e\n\u003cli\u003eSlide VTCC board into designated slot carefully\u003c\/li\u003e\n\u003cli\u003ePush top and bottom levers to seat edge connectors\u003c\/li\u003e\n\u003cli\u003eTighten captive screws at top and bottom of front panel\u003c\/li\u003e\n\u003cli\u003eEnsure proper alignment and connection\u003c\/li\u003e\n\u003cli\u003eFollow safety procedures for rack installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine temperature monitoring and control\u003c\/li\u003e\n\u003cli\u003eSteam turbine temperature measurement systems\u003c\/li\u003e\n\u003cli\u003eWind turbine temperature monitoring applications\u003c\/li\u003e\n\u003cli\u003eIndustrial process temperature measurement\u003c\/li\u003e\n\u003cli\u003eCritical temperature monitoring in power generation\u003c\/li\u003e\n\u003cli\u003eAutomated drive assembly temperature control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSignal Processing Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHardware limit detection for input protection\u003c\/li\u003e\n\u003cli\u003eAutomatic removal of out-of-range inputs\u003c\/li\u003e\n\u003cli\u003ePrevents adverse effects on other channels\u003c\/li\u003e\n\u003cli\u003eHigh accuracy measurement with 16-bit resolution\u003c\/li\u003e\n\u003cli\u003eFast processing with 300 MHz microprocessor\u003c\/li\u003e\n\u003cli\u003eRobust noise rejection for clean signal acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Availability \u0026amp; Services\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eCurrent Status:\u003c\/strong\u003e\u003c\/span\u003e In stock for immediate shipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eRepair Services:\u003c\/strong\u003e\u003c\/span\u003e 3-7 day repair turnaround available\u003c\/li\u003e\n\u003cli\u003eNew and original General Electric component\u003c\/li\u003e\n\u003cli\u003eManufactured by GE Motors and Industrial Systems\u003c\/li\u003e\n\u003cli\u003eComplete with installation and operation documentation\u003c\/li\u003e\n\u003cli\u003eReady for integration into temperature monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocumentation \u0026amp; Support\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefer to GE Manual GEH-6421 for detailed specifications\u003c\/li\u003e\n\u003cli\u003eGEH-6421V manual provides comprehensive guidance\u003c\/li\u003e\n\u003cli\u003eTechnical support available for installation questions\u003c\/li\u003e\n\u003cli\u003eFault indication and diagnostic information documented\u003c\/li\u003e\n\u003cli\u003eComplete operational and maintenance guidelines\u003c\/li\u003e\n\u003cli\u003eSafety and handling instructions provided\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast shipping via FedEx, UPS, and DHL services\u003c\/li\u003e\n\u003cli\u003eOrders typically ship within 24 business hours\u003c\/li\u003e\n\u003cli\u003eInternational shipping available worldwide\u003c\/li\u003e\n\u003cli\u003eComplete tracking information provided\u003c\/li\u003e\n\u003cli\u003eProfessional packaging ensures board protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many thermocouple inputs does this board accept?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS200VTCCH1CBB\u003c\/strong\u003e accepts up to 24 thermocouple inputs for comprehensive temperature monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat thermocouple types are supported?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Type E, J, K, S, and T thermocouples with software linearization for each type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the voltage input range?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts thermocouple signals from -8 mV to +45 mV for precise temperature measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does cold junction compensation work?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUses two cold junction references with averaging, single reference, or default value based on limit compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat A\/D conversion resolution is provided?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures 16-bit analog-to-digital conversion for high-precision temperature measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow are out-of-range inputs handled?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInputs outside hardware limits are automatically removed from scanning to prevent system effects.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47353972982018,"sku":"IS200VTCCH1CBB","price":524.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS200VTCCH1CBB.jpg?v=1770781724","url":"https:\/\/www.nex-auto.com\/products\/ge-is200vtcch1cbb-thermocouple-processor-board","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}