{"product_id":"ge-is215ucvdh7am-mark-vi-input-module-board","title":"GE IS215UCVDH7AM Mark VI Input Module Board","description":"\u003ch2\u003eCore Specifications: GE IS215UCVDH7AM\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eGeneral Electric IS215UCVDH7AM\u003c\/strong\u003e — authentic Mark VI Speedtronic series board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Industrial Systems (Salem, Virginia USA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Input Module Board. Functional acronym \u003cstrong\u003eUCVD\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VI Speedtronic Turbine Control System.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Protection:\u003c\/strong\u003e Full conformal coating. Thin chemically applied layer protects all components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Revisions:\u003c\/strong\u003e Dual revisions — 1A and 2M. Modified version of parent IS215UCVDH7 board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup:\u003c\/strong\u003e Group 7 Mark VI Series classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDiagnostic LED Indicators\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Faceplate LEDs:\u003c\/strong\u003e Six status indicators for controller and communication health.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eACTIVE:\u003c\/strong\u003e Board operational status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMAS:\u003c\/strong\u003e Backup master status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSLOT1:\u003c\/strong\u003e Slot identification indicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENET:\u003c\/strong\u003e Ethernet link status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSYS:\u003c\/strong\u003e System health monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBSLV:\u003c\/strong\u003e Backup slave status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuntime Error Codes:\u003c\/strong\u003e Ten H\/L LEDs. Display specific runtime error codes during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Value:\u003c\/strong\u003e Technicians read these LEDs instantly. No software needed for basic fault identification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConnectivity \u0026amp; Communication Ports\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitor Port:\u003c\/strong\u003e GE-designated port. Factory use only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMouse Port:\u003c\/strong\u003e GE-designated port. Not for field peripheral connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyboard Port:\u003c\/strong\u003e GE-designated port. Reserved for manufacturer access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOM1:\u003c\/strong\u003e RS-232C serial port. Use for initial controller setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOM2:\u003c\/strong\u003e RS-232C serial port. Handles serial communications during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Port:\u003c\/strong\u003e Supports UDH (Unit Data Highway) communications. Primary data link.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISBus Drive LAN Ports:\u003c\/strong\u003e Physically present. Unused in standard Mark VI configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHardware Protection \u0026amp; PCB Coating\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Factory-applied thin chemical layer. Covers entire board surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Scope:\u003c\/strong\u003e Shields LEDs, ports, ICs, and passive components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e Guards against moisture, dust, vibration, and conductive contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Coating is transparent. All component labels and LEDs remain visible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability:\u003c\/strong\u003e Extends PCB service life in turbine control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFunctional Revision \u0026amp; Product Lineage\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eParent Board:\u003c\/strong\u003e Derived from \u003cstrong\u003eIS215UCVDH7\u003c\/strong\u003e. The AM variant includes two functional revisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision 1A:\u003c\/strong\u003e Base functional revision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision 2M:\u003c\/strong\u003e Secondary functional revision. Modifies parent board behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModification Benefit:\u003c\/strong\u003e Offers enhanced compatibility or corrected errata from original H7 design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Original GE factory manuals available. Functional description remains Input Module Board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMechanical \u0026amp; Physical Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e Mark VI standard module size. Fits dedicated UCVD slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaceplate:\u003c\/strong\u003e Front panel with cutouts for all LEDs and ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Rack-mounted within Mark VI control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Layering:\u003c\/strong\u003e Multi-layer surface mount design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States. GE Industrial Systems, Salem VA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping \u0026amp; Availability\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock Status:\u003c\/strong\u003e In stock and ready to ship.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Anti-static ESD bag. Foam-lined industrial box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat You Receive:\u003c\/strong\u003e 1x \u003cstrong\u003eGE IS215UCVDH7AM\u003c\/strong\u003e Input Module Board. No cables or mounting hardware included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the difference between IS215UCVDH7 and IS215UCVDH7AM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AM variant carries two functional revisions: 1A and 2M. The parent H7 board typically carries a single revision. The AM version also includes specific component updates verified during Salem production.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Can I use the mouse, keyboard, and monitor ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. GE designates these ports for factory use only. They do not function as standard peripheral interfaces in the field. Use COM1 and COM2 for setup and serial tasks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What do the ten H\/L runtime LEDs tell me?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThey display numeric error codes. Each H\/L combination represents a specific runtime fault. Refer to GEH-6721 manual series for code translation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Is the ISBus Drive LAN port required for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Original GE documentation states these ports remain unused. You do not need to connect them. The ethernet port handles all UDH communications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. How do I verify conformal coating integrity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePerform a visual inspection under bright light. The coating should appear uniform and glossy. No bare pads or lifted areas. No flaking or peeling at connector edges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Buying advice: Should I choose the H7AM revision over older UCVD boards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \u003cstrong\u003eIS215UCVDH7AM\u003c\/strong\u003e includes both revision A and M updates. It is the most current UCVD variant for Mark VI systems. It resolves known issues from early H7 production runs. Always verify your system group compatibility, but this board suits most Mark VI turbine retrofit projects.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47358133534978,"sku":"IS215UCVDH7AM","price":620.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS215UCVDH7AM-2.jpg?v=1770876604","url":"https:\/\/www.nex-auto.com\/products\/ge-is215ucvdh7am-mark-vi-input-module-board","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}