{"product_id":"ge-is220yturs1a-turbine-protection-module-mark-vies","title":"GE IS220YTURS1A Turbine Protection Module Mark VIeS","description":"\u003ch2\u003e\u003cstrong\u003eCritical Safety Protection for Industrial Turbines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Electric\u003c\/strong\u003e engineered the \u003cstrong\u003eIS220YTURS1A\u003c\/strong\u003e for reliable turbine protection. This Primary Turbine Protection I\/O Module works within \u003cstrong\u003eMark VIeS\u003c\/strong\u003e safety systems. It provides essential monitoring and shutdown functions for industrial turbine operations.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e\u003c\/span\u003e General Electric \u003cstrong\u003eIS220YTURS1A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e Primary Turbine Protection I\/O Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003c\/span\u003e Mark VIeS Safety System\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003c\/span\u003e 6 input\/output channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003c\/span\u003e 28 VDC nominal (27.4-28.6 VDC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eContact Rating:\u003c\/strong\u003e\u003c\/span\u003e 125 VDC maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e -30°C to +65°C ambient\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Protection Functions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors up to four passive magnetic speed sensor inputs\u003c\/li\u003e\n\u003cli\u003eProvides flame detection for eight separate flame sensors\u003c\/li\u003e\n\u003cli\u003eInterfaces with electrical trip devices (ETD) via relay outputs\u003c\/li\u003e\n\u003cli\u003eHandles bus voltage, generator voltage, and shaft signals\u003c\/li\u003e\n\u003cli\u003eControls outputs to main breaker for emergency shutdown\u003c\/li\u003e\n\u003cli\u003eSupports hardware fault-tolerant channel operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInput \u0026amp; Output Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSpeed Inputs:\u003c\/strong\u003e\u003c\/span\u003e 2 to 20,000 Hz frequency range\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eFlame Detection:\u003c\/strong\u003e\u003c\/span\u003e Triggers on pulses above 2.5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eAnalog I\/O:\u003c\/strong\u003e\u003c\/span\u003e 4-20mA signal feedback capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003c\/span\u003e Modbus protocol support\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003c\/span\u003e 120V AC operational\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eOutput Range:\u003c\/strong\u003e\u003c\/span\u003e 5V to 24V DC adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCompatibility \u0026amp; Integration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for use with \u003cstrong\u003eMark VIeS\u003c\/strong\u003e safety systems\u003c\/li\u003e\n\u003cli\u003eCompatible with TTUR and TRPA terminal boards\u003c\/li\u003e\n\u003cli\u003ePlug-and-play with TTURS1C, TRPAS1A, TRPAS2A terminal boards\u003c\/li\u003e\n\u003cli\u003eWorks with TRPGS1B and TRPGS2B for trip relay applications\u003c\/li\u003e\n\u003cli\u003eFeatures box connector types for secure terminal connections\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting for easy panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e 3.4 x 6.37 inches (86 x 162 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/span\u003e 2.00 lbs (0.91 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePCB Coating:\u003c\/strong\u003e\u003c\/span\u003e S-style conformal coating\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eRevision Level:\u003c\/strong\u003e\u003c\/span\u003e Functional Revision A\u003c\/li\u003e\n\u003cli\u003eManufactured in the United States\u003c\/li\u003e\n\u003cli\u003eIncludes special assembly features for enhanced reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Availability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThis module is \u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ecurrently in stock\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNew and original General Electric product\u003c\/li\u003e\n\u003cli\u003eShips in protective factory packaging\u003c\/li\u003e\n\u003cli\u003eImmediate availability for urgent requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOrders typically ship within 24 hours of placement\u003c\/li\u003e\n\u003cli\u003eExpress shipping available via FedEx, UPS, and DHL\u003c\/li\u003e\n\u003cli\u003eInternational shipping to most global destinations\u003c\/li\u003e\n\u003cli\u003eComplete tracking information provided for all shipments\u003c\/li\u003e\n\u003cli\u003eProfessional packaging ensures safe transit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation \u0026amp; Configuration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConsult GE manual GEH-6721P for complete installation guidelines\u003c\/li\u003e\n\u003cli\u003eVerify proper terminal board compatibility before installation\u003c\/li\u003e\n\u003cli\u003eEnsure power supply remains within 27.4-28.6 VDC range\u003c\/li\u003e\n\u003cli\u003eMaintain ambient temperature within specified operating limits\u003c\/li\u003e\n\u003cli\u003eConfigure speed and flame detection parameters per application\u003c\/li\u003e\n\u003cli\u003eTest all protection functions before placing system in service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTesting \u0026amp; Commissioning\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest speed inputs by varying signals and comparing to reference\u003c\/li\u003e\n\u003cli\u003eVerify flame detection operation by observing flame presence\u003c\/li\u003e\n\u003cli\u003eTest E-Stop input by actuating and observing PTR drop-out\u003c\/li\u003e\n\u003cli\u003eCheck system maintains outputs during communication loss\u003c\/li\u003e\n\u003cli\u003eValidate all configurable items (CFG) are properly set\u003c\/li\u003e\n\u003cli\u003eEnsure no diagnostic faults exist before operational use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the primary function of this module?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS220YTURS1A\u003c\/strong\u003e provides primary turbine protection including speed monitoring, flame detection, and emergency trip functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many speed sensors can it monitor?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIt can interface with up to four passive magnetic speed sensors simultaneously.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat terminal boards are compatible?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible boards include TTURS1C, TRPAS1A, TRPAS2A, TRPGS1B, and TRPGS2B.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the operating voltage range?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module operates on 28 VDC nominal, with an acceptable range of 27.4 to 28.6 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIs this a safety-certified module?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYes, the \u003cstrong\u003eIS220YTURS1A\u003c\/strong\u003e is part of the \u003cstrong\u003eMark VIeS\u003c\/strong\u003e safety system with certified protection functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhere can I find technical documentation?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRefer to GE manual GEH-6721P for complete specifications, installation, and testing procedures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47349889892610,"sku":"IS220YTURS1A","price":721.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS220YTURS1A.jpg?v=1770705609","url":"https:\/\/www.nex-auto.com\/products\/ge-is220yturs1a-turbine-protection-module-mark-vies","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}