{"product_id":"general-electric-paic-module-is220paich1b","title":"General Electric PAIC Module IS220PAICH1B","description":"\u003ch2\u003e\u003cstrong\u003ePrecision Analog Interface for Industrial Control\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Electric\u003c\/strong\u003e developed the \u003cstrong\u003eIS220PAICH1B\u003c\/strong\u003e for accurate process monitoring. This Analog I\/O Pack serves within \u003cstrong\u003eMark VIe\u003c\/strong\u003e distributed control systems. It provides reliable signal conversion between field devices and control networks.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e\u003c\/span\u003e General Electric \u003cstrong\u003eIS220PAICH1B\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e Analog Input\/Output Pack\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003c\/span\u003e Mark VIe Distributed I\/O System\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003c\/span\u003e 10 analog inputs, 2 analog outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003c\/span\u003e 16-bit analog-to-digital conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eScan Time:\u003c\/strong\u003e\u003c\/span\u003e 5 ms normal (200 Hz maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/span\u003e 5.3W typical, 6.2W maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAnalog Input Capabilities\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eChannels 1-8: Configurable as 5V, 10V, or 0-20mA inputs\u003c\/li\u003e\n\u003cli\u003eChannels 9-10: Selectable as 0-20mA or ±1mA current inputs\u003c\/li\u003e\n\u003cli\u003eInput ranges include 1-5V, ±5V, ±10V, and current loop\u003c\/li\u003e\n\u003cli\u003eTerminal board includes 250Ω burden resistors for current sensing\u003c\/li\u003e\n\u003cli\u003eAnalog multiplexer with configurable gain and scaling options\u003c\/li\u003e\n\u003cli\u003eVoltage sensing across terminal board load resistors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAnalog Output Functions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTwo independent 0-20mA current loop outputs\u003c\/li\u003e\n\u003cli\u003e18V compliance voltage for simplex or TMR operation\u003c\/li\u003e\n\u003cli\u003e14-bit digital-to-analog converter for precise control\u003c\/li\u003e\n\u003cli\u003eCurrent regulator loop monitors both pack and terminal board\u003c\/li\u003e\n\u003cli\u003eNormally-open mechanical relays for output enable\/disable\u003c\/li\u003e\n\u003cli\u003eSuicide relay function isolates failed outputs in TMR systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Integration \u0026amp; Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces with one or two I\/O Ethernet networks (IONet)\u003c\/li\u003e\n\u003cli\u003eCompatible terminal boards: IS200TBAIH1C, IS200TAIH1A, IS200TAIH2A\u003c\/li\u003e\n\u003cli\u003eAuto-Reconfiguration feature for easy pack replacement\u003c\/li\u003e\n\u003cli\u003eProcessor verifies board ID matching with application code\u003c\/li\u003e\n\u003cli\u003eThree-pin power input with two RJ45 Ethernet connectors\u003c\/li\u003e\n\u003cli\u003eDC-37 pin connector for terminal board interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental \u0026amp; Safety Ratings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003c\/span\u003e -40°F to 158°F (-40°C to 70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eATEX Certification:\u003c\/strong\u003e\u003c\/span\u003e Zone 2, Group IIC hazardous areas\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eNon-Hazardous:\u003c\/strong\u003e\u003c\/span\u003e UL E207685 certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/span\u003e EN 60079-11:2012, EN 60079-7:2015, EN 60079-0:2018\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003c\/span\u003e 22.5-28 VDC (24\/28 VDC nominal)\u003c\/li\u003e\n\u003cli\u003eManufactured in the United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDiagnostics \u0026amp; Monitoring\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLED indicator lights provide visual status information\u003c\/li\u003e\n\u003cli\u003eAlarm 66-67: Output current too high relative to total current\u003c\/li\u003e\n\u003cli\u003eAlarm 82-83: Suicide relay non-functional detection\u003c\/li\u003e\n\u003cli\u003eProcessor performs self-test routines during startup\u003c\/li\u003e\n\u003cli\u003eDetects compressor stall conditions within 30 seconds\u003c\/li\u003e\n\u003cli\u003eValidates configuration matching between components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Availability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNew and original General Electric component\u003c\/li\u003e\n\u003cli\u003eFunctional Revision B with updated specifications\u003c\/li\u003e\n\u003cli\u003eImmediate availability from stock inventory\u003c\/li\u003e\n\u003cli\u003eShips in original protective packaging\u003c\/li\u003e\n\u003cli\u003eComplete with all necessary hardware components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast shipping via FedEx, UPS, and DHL services\u003c\/li\u003e\n\u003cli\u003eOrders typically process within 24 business hours\u003c\/li\u003e\n\u003cli\u003eInternational shipping to most global destinations\u003c\/li\u003e\n\u003cli\u003eReal-time tracking information provided\u003c\/li\u003e\n\u003cli\u003eProfessional packaging ensures component protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation \u0026amp; Configuration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum wire size: 22 AWG for terminal connections\u003c\/li\u003e\n\u003cli\u003eVerify proper terminal board compatibility before installation\u003c\/li\u003e\n\u003cli\u003eEnsure power supply voltage within 22.5-28 VDC range\u003c\/li\u003e\n\u003cli\u003eMaintain ambient temperature within specified limits\u003c\/li\u003e\n\u003cli\u003eConfigure input types and ranges per application requirements\u003c\/li\u003e\n\u003cli\u003eTest all channels and outputs before system commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat types of signals can this module handle?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS220PAICH1B\u003c\/strong\u003e accepts voltage (1-5V, ±5V, ±10V) and current (0-20mA, ±1mA) signals on different channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many input and output channels does it have?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis PAIC pack provides 10 analog input channels and 2 analog output channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the scan rate of this module?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNormal scan time is 5 ms (200 Hz), though maximum controller frame rate is 100 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCan this be used in hazardous areas?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYes, the \u003cstrong\u003eIS220PAICH1B\u003c\/strong\u003e carries ATEX Zone 2 certification for Group IIC hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat terminal boards are compatible?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible boards include IS200TBAIH1C, IS200TAIH1A, and IS200TAIH2A terminal boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does the suicide relay do?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe suicide relay isolates a failed output in TMR systems, allowing the remaining outputs to function correctly without interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47349890744578,"sku":"IS220PAICH1B","price":752.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS220PAICH1B.jpg?v=1770706121","url":"https:\/\/www.nex-auto.com\/products\/general-electric-paic-module-is220paich1b","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}