{"product_id":"gt-75a-keyence-digital-contact-sensor-amplifier","title":"GT-75A Keyence Digital Contact Sensor Amplifier","description":"\u003ch2\u003e\u003cstrong\u003eGT-75A Keyence Digital Contact Sensor Amplifier – Panel Mount NPN Main Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Keyence\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eGT-75A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e GT series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Digital contact sensor amplifier unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay range:\u003c\/strong\u003e -99.999 to 999.999\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay resolution:\u003c\/strong\u003e 1 µm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling rate:\u003c\/strong\u003e 2,000 times\/second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e Selectable hsp (1.5 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s, and 5 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput type:\u003c\/strong\u003e HIGH\/GO\/LOW NPN open collector, 50 mA max, 40 V or less\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual voltage:\u003c\/strong\u003e 1 V or less, N.O.\/N.C. selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 12 to 24 VDC, ripple (p-p) 10 % or less\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 1,140 mW (95 mA) or less at 12 V in normal mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 1,200 mW (50 mA) or less at 24 V in normal mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEco mode:\u003c\/strong\u003e 600 mW (50 mA) at 12 V, 840 mW (35 mA) at 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -10 to +55 °C, no freezing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 35 to 85 % RH, no condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 110 g including power cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel mount, main unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 1 µm resolution supports fine dimensional checks on small parts.\u003c\/li\u003e\n\u003cli\u003eA 2,000 times\/second sampling rate captures fast moving targets.\u003c\/li\u003e\n\u003cli\u003eSeven selectable response times let you balance speed and stability.\u003c\/li\u003e\n\u003cli\u003eThe NPN open collector output handles up to 50 mA directly.\u003c\/li\u003e\n\u003cli\u003eN.O.\/N.C. switching gives you flexible wiring for different machines.\u003c\/li\u003e\n\u003cli\u003eEco mode cuts power draw to 600 mW at 12 V for energy savings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eGT-75A\u003c\/strong\u003e main unit into a panel cutout for a fixed setup.\u003c\/li\u003e\n\u003cli\u003eConnect 12 to 24 VDC power and keep ripple below 10 % (p-p).\u003c\/li\u003e\n\u003cli\u003eWire the HIGH\/GO\/LOW NPN outputs to your controller or PLC input.\u003c\/li\u003e\n\u003cli\u003eSet N.O. or N.C. logic to match your machine sequence.\u003c\/li\u003e\n\u003cli\u003eChoose a response time from hsp (1.5 ms) up to 5 s for your task.\u003c\/li\u003e\n\u003cli\u003eAdd optional GT series communication units when you need fieldbus links.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe main unit ships without built-in ports or protocols.\u003c\/li\u003e\n\u003cli\u003eOptional GT series communication units add network connectivity.\u003c\/li\u003e\n\u003cli\u003eYou buy these expansion units separately from Keyence.\u003c\/li\u003e\n\u003cli\u003eThis design keeps the base amplifier compact and cost efficient.\u003c\/li\u003e\n\u003cli\u003eExpansion modules slot in without changing the panel footprint.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Durability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe amplifier runs from -10 to +55 °C without freezing.\u003c\/li\u003e\n\u003cli\u003eHumidity tolerance spans 35 to 85 % RH with no condensation.\u003c\/li\u003e\n\u003cli\u003eStable electronics resist drift across the rated temperature band.\u003c\/li\u003e\n\u003cli\u003eShielded wiring and stable supply voltage reduce electrical noise.\u003c\/li\u003e\n\u003cli\u003eThe unit suits machine tools, assembly lines, and inspection stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Keyence \u003cstrong\u003eGT-75A\u003c\/strong\u003e digital contact sensor amplifier main unit\u003c\/li\u003e\n\u003cli\u003e1 × Power cable\u003c\/li\u003e\n\u003cli\u003eShipping via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the display resolution of the GT-75A?\u003c\/strong\u003e A: The \u003cstrong\u003eGT-75A\u003c\/strong\u003e shows 1 µm resolution across its -99.999 to 999.999 range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How fast does this amplifier sample?\u003c\/strong\u003e A: It samples 2,000 times per second for quick measurement updates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I change the response time?\u003c\/strong\u003e A: Yes, you select from hsp (1.5 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s, or 5 s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What output type does it use?\u003c\/strong\u003e A: It provides HIGH\/GO\/LOW NPN open collector outputs at 50 mA max.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it include communication ports?\u003c\/strong\u003e A: No, you add optional GT series communication units for networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power supply do I need?\u003c\/strong\u003e A: Use 12 to 24 VDC with ripple of 10 % (p-p) or less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is the item in stock?\u003c\/strong\u003e A: Yes, we hold brand new original stock and ship within 5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping methods do you offer?\u003c\/strong\u003e A: We ship by common carriers such as DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I return the product?\u003c\/strong\u003e A: Yes, we accept returns within 30 days of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Keyence","offers":[{"title":"Default Title","offer_id":51125637316866,"sku":"GT-75A","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/GT-75A-2.jpg?v=1795059284","url":"https:\/\/www.nex-auto.com\/products\/gt-75a-keyence-digital-contact-sensor-amplifier","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}