{"product_id":"honeywell-48vdc-safe-output-module-fs-sdo-0448","title":"Honeywell 48VDC Safe Output Module FS-SDO-0448","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell FS-SDO-0448 Safe Digital Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e74b5;\"\u003eHoneywell FS-SDO-0448\u003c\/strong\u003e is a high-integrity digital output module engineered for safety-critical control systems. Featuring 4 independent channels with 48VDC switching capability, this module delivers reliable power control while maintaining the stringent requirements of safety instrumented systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eFS-SDO-0448\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Safe Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e \u003cstrong style=\"color: #c65911;\"\u003e4 Channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e \u003cstrong style=\"color: #c65911;\"\u003e48 VDC\u003c\/strong\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e \u003cstrong style=\"color: #c65911;\"\u003e0.75 A\u003c\/strong\u003e per channel continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e \u003cstrong style=\"color: #c65911;\"\u003eSIL 3 (IEC 61508)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Switching Type:\u003c\/strong\u003e Protected MOSFET solid-state output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Resistance:\u003c\/strong\u003e ≤ 0.25 Ω at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Power Dissipation:\u003c\/strong\u003e 1.8 W per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current:\u003c\/strong\u003e \u0026lt; 50 μA at 48VDC (off-state)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Electronic current limiting, auto-recovery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e Up to 100 Hz maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTiming Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurn-On Delay Time:\u003c\/strong\u003e ≤ 1.5 ms (command to 90% output)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurn-Off Delay Time:\u003c\/strong\u003e ≤ 1.0 ms (command to 10% output)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Test Interval:\u003c\/strong\u003e Configurable from 10 ms to 10 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Detection Time:\u003c\/strong\u003e \u0026lt; 50 ms for short-circuit conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Fault Tolerance (HFT):\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integrity Level:\u003c\/strong\u003e SIL 3 (IEC 61508), PLe (ISO 13849-1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Coverage:\u003c\/strong\u003e \u0026gt; 99% (per IEC 61508 requirements)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePFH (Probability of Dangerous Failure per Hour):\u003c\/strong\u003e \u0026lt; 1×10⁻⁸\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArchitecture:\u003c\/strong\u003e Dual-path with continuous cross-monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Diagnostics:\u003c\/strong\u003e Open-load detection, short-to-ground detection, overtemperature monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Diagnostics:\u003c\/strong\u003e Supply voltage monitoring, watchdog timer, memory checksum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indication:\u003c\/strong\u003e Per-channel dual-color LEDs (green\/red)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Diagnostics:\u003c\/strong\u003e Fault reporting via safety bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Functions:\u003c\/strong\u003e Programmable pulse test for fault detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIsolation \u0026amp; Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 500 V AC RMS (channel to logic, channel to channel)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e 2.2 kV AC for 60 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e 1 kV per IEC 61000-4-5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e 8 kV contact, 15 kV air per IEC 61000-4-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Category:\u003c\/strong\u003e III per IEC 60664-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 5-150 Hz, 2.0 G (operational)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 G, 11 ms half-sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20 (requires enclosure)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Supply:\u003c\/strong\u003e 5 VDC ±5%, 120 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Supply:\u003c\/strong\u003e 24-48 VDC, 100 mA (module consumption)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Module Power:\u003c\/strong\u003e ≤ 6 W maximum (all channels active)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e \u0026lt; 2 A for 10 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions:\u003c\/strong\u003e 110 × 75 × 35 mm (H × W × D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 220 grams\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail TS35\/7.5 or TS35\/15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Removable spring-cage terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Range:\u003c\/strong\u003e 0.2-2.5 mm² (AWG 24-14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 0.4-0.6 Nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance \u0026amp; Approvals\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e IEC 61508, IEC 61511, ISO 13849-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e EN 61326-1 (industrial), FCC Part 15 Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL 508, CSA C22.2 No. 142, CE marked\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Approvals:\u003c\/strong\u003e DNV-GL, ABS (pending)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e ATEX Zone 2, Class I Div 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety shutdown solenoids and valves\u003c\/li\u003e\n\u003cli\u003eEmergency stop circuits\u003c\/li\u003e\n\u003cli\u003eFire suppression system actuators\u003c\/li\u003e\n\u003cli\u003eProcess interlock final elements\u003c\/li\u003e\n\u003cli\u003eCritical machine safety controls\u003c\/li\u003e\n\u003cli\u003eAlarm and annunciation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Controllers:\u003c\/strong\u003e Honeywell Safety Manager SC, Experion HS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Software:\u003c\/strong\u003e Safety Builder 4.0 or higher\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Interface:\u003c\/strong\u003e Safety-rated fieldbus protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swap Capable:\u003c\/strong\u003e Yes, with automatic configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMean Time To Repair (MTTR):\u003c\/strong\u003e \u0026lt; 15 minutes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47159471767810,"sku":"FS-SDO-0448","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/FS-SDO-0448.jpg?v=1766391285","url":"https:\/\/www.nex-auto.com\/products\/honeywell-48vdc-safe-output-module-fs-sdo-0448","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}