{"product_id":"innpm01-abb-npm-infi-net-controlway-module","title":"INNPM01 | ABB NPM | INFI-NET Controlway Module","description":"\u003ch2\u003e\u003cstrong\u003eABB INNPM01 Network Processing Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eABB INNPM01\u003c\/strong\u003e Network Processing Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e Routes exception reports and manages communication between INFI-NET and Controlway.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Capacity:\u003c\/strong\u003e Includes 256 kbytes of ROM and 512 kbytes of RAM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e Requires +5 VDC at 2 A. Nominal power consumption is 10 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Rates:\u003c\/strong\u003e Supports 1 Mbaud on the Controlway and 83.3 kbaud on the module bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting \u0026amp; Weight:\u003c\/strong\u003e Occupies one slot in a standard INFI 90 module mounting unit. Weighs 0.45 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoll Rate Selection:\u003c\/strong\u003e Dipswitch settings on the PCB allow poll rates of 1, 2, 4, or 8 polls per second.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eException Report Handling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolling Mechanism:\u003c\/strong\u003e The \u003cstrong\u003eINNPM01\u003c\/strong\u003e polls all control modules within the process control unit for exception reports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReport Triggers:\u003c\/strong\u003e Control modules generate an exception report when a designated point changes significantly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Triggers:\u003c\/strong\u003e Reports also occur when the maximum time expires or when an alarm condition changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLED Indicators \u0026amp; Controls\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LED:\u003c\/strong\u003e Solid green indicates execute mode. Solid red signals a hardware failure or configuration issue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU LEDs:\u003c\/strong\u003e Eight CPU LEDs display error codes when the status LED is red.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStop\/Reset Button:\u003c\/strong\u003e A pushbutton on the faceplate allows you to stop or reset the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Off:\u003c\/strong\u003e Indicates no power is supplied to the \u003cstrong\u003eINNPM01\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEdge Connector Pin Assignment (P1)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connections:\u003c\/strong\u003e +5 VDC on pins 1 and 2. Common on pins 5 and 6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Controlway B on pin 4. Controlway A \/ Module Bus on pin 11.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Signals:\u003c\/strong\u003e Power Supply Status on pin 3. Power Fail Interrupt on pin 9.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnused Pins:\u003c\/strong\u003e Pins 7, 8, 10, and 12 are reserved and have no connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Packaging\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1x \u003cstrong\u003eABB INNPM01\u003c\/strong\u003e Network Processing Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e We ship globally using FedEx, DHL, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Time:\u003c\/strong\u003e We ship all in-stock orders within 5 business days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the ABB INNPM01 new or refurbished?\u003c\/strong\u003e We stock only brand new, original \u003cstrong\u003eINNPM01\u003c\/strong\u003e modules from ABB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the typical lead time for this NPM module?\u003c\/strong\u003e We usually dispatch the \u003cstrong\u003eINNPM01\u003c\/strong\u003e within 3 to 5 working days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I return the module if it doesn't meet my needs?\u003c\/strong\u003e Yes. We support returns within 30 days of delivery. Contact us to initiate the process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the communication rates of the INNPM01?\u003c\/strong\u003e The module supports 1 Mbaud on Controlway and 83.3 kbaud on the module bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48254111973634,"sku":"INNPM01","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/INNPM01-1.jpg?v=1785921101","url":"https:\/\/www.nex-auto.com\/products\/innpm01-abb-npm-infi-net-controlway-module","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}