{"product_id":"is200vturh1bab-ge-mark-vi-vibration-transducer-interface-module","title":"IS200VTURH1BAB GE Mark VI Vibration Transducer Interface Module","description":"\u003ch2\u003e\u003cstrong\u003eComprehensive Primary Turbine Protection and Control\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Electric\u003c\/strong\u003e engineered the \u003cstrong\u003eIS200VTURH1BAB\u003c\/strong\u003e for critical turbine safety. This Primary Turbine Protection Card operates within \u003cstrong\u003eMark VI\u003c\/strong\u003e Speedtronic systems. It provides essential overspeed protection, flame detection, and generator synchronization functions.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e\u003c\/span\u003e General Electric \u003cstrong\u003eIS200VTURH1BAB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e Primary Turbine Protection Card\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003c\/span\u003e Mark VI Speedtronic System\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eBoard Rating:\u003c\/strong\u003e\u003c\/span\u003e 125 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eCommon Mode Voltage:\u003c\/strong\u003e\u003c\/span\u003e ±5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/span\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eAnalog Voltage Inputs:\u003c\/strong\u003e\u003c\/span\u003e 6 channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSpeed Measurement \u0026amp; Overspeed Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFour passive pulse rate devices for turbine speed measurement\u003c\/li\u003e\n\u003cli\u003eFrequency range: 2 Hz to 20,000 Hz\u003c\/li\u003e\n\u003cli\u003eDetects 2 RPM turning gear speed with sixty-tooth wheel\u003c\/li\u003e\n\u003cli\u003eIdentifies turbine stoppage (zero speed) conditions\u003c\/li\u003e\n\u003cli\u003eRelays speed data to controller for primary overspeed trip\u003c\/li\u003e\n\u003cli\u003eActivates turning gear operation when speed drops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFlame Detection System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors eight Geiger-Mueller flame detectors in gas turbines\u003c\/li\u003e\n\u003cli\u003eLinked to TRPG terminal board for integrated protection\u003c\/li\u003e\n\u003cli\u003eExternal power supply: 335 VDC, 0.5 mA\u003c\/li\u003e\n\u003cli\u003eEssential for early flame irregularity detection\u003c\/li\u003e\n\u003cli\u003eSwift response and mitigation for critical situations\u003c\/li\u003e\n\u003cli\u003eGas turbine specific monitoring capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePrimary Trip Solenoid Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControls three primary overspeed trip relays on TRPx board\u003c\/li\u003e\n\u003cli\u003eController calculates and transmits trip signals to VTUR\u003c\/li\u003e\n\u003cli\u003eSignals forwarded to TRPG for emergency solenoid activation\u003c\/li\u003e\n\u003cli\u003eOverspeed trips can originate from VTUR or VPRO\u003c\/li\u003e\n\u003cli\u003eNine magnetic relays interface with three trip solenoids\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTMR Systems:\u003c\/strong\u003e\u003c\/span\u003e Nine relays employed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eSimplex Systems:\u003c\/strong\u003e\u003c\/span\u003e Three relays utilized\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShaft Monitoring \u0026amp; Voltage Sensing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors induced shaft voltage with brush capture\u003c\/li\u003e\n\u003cli\u003eTracks current to machine casing\u003c\/li\u003e\n\u003cli\u003eAlarms for excessive voltage and current levels\u003c\/li\u003e\n\u003cli\u003eProvides insights into turbine operating conditions\u003c\/li\u003e\n\u003cli\u003eEarly detection of potential electrical issues\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring for optimal performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eGenerator Synchronization\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic generator synchronization capability\u003c\/li\u003e\n\u003cli\u003eManages main breaker relay coil 52G closure\u003c\/li\u003e\n\u003cli\u003eTTUR provides permissive generator synchronizing relays\u003c\/li\u003e\n\u003cli\u003eWorks with turbine controller and excitation system\u003c\/li\u003e\n\u003cli\u003eSeamless coordination between generator systems\u003c\/li\u003e\n\u003cli\u003eEnhances operational efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFront Panel Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-slot sturdy metal faceplate\u003c\/li\u003e\n\u003cli\u003eOne cable connector labeled J5 for interfacing\u003c\/li\u003e\n\u003cli\u003eThree LED indicators for critical diagnostic information\u003c\/li\u003e\n\u003cli\u003eDisplays functional fault statuses including fatal faults\u003c\/li\u003e\n\u003cli\u003eVisual diagnostics for immediate operator feedback\u003c\/li\u003e\n\u003cli\u003eQuick troubleshooting and status verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Board Components\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOver five dozen integrated circuits\u003c\/li\u003e\n\u003cli\u003e13 transistors for signal processing\u003c\/li\u003e\n\u003cli\u003eTwo backplane connectors for VME rack integration\u003c\/li\u003e\n\u003cli\u003eMulti-position plug for daughterboard mounting\u003c\/li\u003e\n\u003cli\u003eResistors, diodes, and capacitors throughout\u003c\/li\u003e\n\u003cli\u003eMarkings: Type 6, 94V-0, and 6BA01 codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTrip Board Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTRPG:\u003c\/strong\u003e\u003c\/span\u003e Gas turbine applications with TREG for emergency trips\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTRPS:\u003c\/strong\u003e\u003c\/span\u003e Small and medium steam turbine systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eTRPL:\u003c\/strong\u003e\u003c\/span\u003e Large steam turbine systems for emergency scenarios\u003c\/li\u003e\n\u003cli\u003eSupports up to three ETDs per TRPx\/TREx combination\u003c\/li\u003e\n\u003cli\u003eDiscrete inputs for trip relay position monitoring\u003c\/li\u003e\n\u003cli\u003eSynchronizing relay coil activation and ETD power status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Architecture Support\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for both simplex and TMR configurations\u003c\/li\u003e\n\u003cli\u003eFlexible deployment based on application requirements\u003c\/li\u003e\n\u003cli\u003eConnected HMI for centralized information access\u003c\/li\u003e\n\u003cli\u003eGroup 1 Mark VI Series product grouping\u003c\/li\u003e\n\u003cli\u003eConformal PCB coating for environmental protection\u003c\/li\u003e\n\u003cli\u003eThree-fold product revision history\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation \u0026amp; Integration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVME rack installation for standard system integration\u003c\/li\u003e\n\u003cli\u003eFactory-drilled mounting ensures board integrity\u003c\/li\u003e\n\u003cli\u003eSingle-slot faceplate for rack mounting compatibility\u003c\/li\u003e\n\u003cli\u003eNo permeation of base printed circuit board\u003c\/li\u003e\n\u003cli\u003eRefer to GEH-6421I manual for complete instructions\u003c\/li\u003e\n\u003cli\u003eFollow GE publications for alarm faults and handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDiscrete Input Monitoring\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors trip relay position status\u003c\/li\u003e\n\u003cli\u003eTracks synchronizing relay coil activation\u003c\/li\u003e\n\u003cli\u003eVerifies ETD power status\u003c\/li\u003e\n\u003cli\u003eEnables comprehensive system diagnostics\u003c\/li\u003e\n\u003cli\u003eSupports fault detection and troubleshooting\u003c\/li\u003e\n\u003cli\u003eEnsures reliable trip board functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Availability \u0026amp; Services\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eCurrent Status:\u003c\/strong\u003e\u003c\/span\u003e In stock for immediate shipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e\u003cstrong\u003eRepair Services:\u003c\/strong\u003e\u003c\/span\u003e 3-7 day repair turnaround available\u003c\/li\u003e\n\u003cli\u003eNew and original General Electric component\u003c\/li\u003e\n\u003cli\u003ePart of last Speedtronic turbine management systems\u003c\/li\u003e\n\u003cli\u003eManufactured in the United States\u003c\/li\u003e\n\u003cli\u003eComplete with necessary documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine overspeed protection systems\u003c\/li\u003e\n\u003cli\u003eSteam turbine primary trip control\u003c\/li\u003e\n\u003cli\u003eGenerator synchronization and breaker management\u003c\/li\u003e\n\u003cli\u003eFlame detection and monitoring for gas turbines\u003c\/li\u003e\n\u003cli\u003eShaft voltage and current condition monitoring\u003c\/li\u003e\n\u003cli\u003eCritical turbine safety system implementations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast shipping via FedEx, UPS, and DHL services\u003c\/li\u003e\n\u003cli\u003eOrders typically ship within 24 business hours\u003c\/li\u003e\n\u003cli\u003eInternational shipping available worldwide\u003c\/li\u003e\n\u003cli\u003eComplete tracking information provided\u003c\/li\u003e\n\u003cli\u003eProfessional packaging ensures board protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the primary function of this board?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eIS200VTURH1BAB\u003c\/strong\u003e provides primary turbine protection including overspeed trip, flame detection, and generator synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many speed sensors does it support?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports up to four passive magnetic speed inputs with 2 Hz to 20 kHz range, detecting 2 RPM turning gear speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many flame detectors can it monitor?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors eight Geiger-Mueller flame detectors in gas turbine applications with 335 VDC external power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat trip boards are compatible?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with TRPG (gas), TRPS (small\/medium steam), and TRPL (large steam) terminal boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow many relays are used in different configurations?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUses nine relays in TMR systems and three relays in simplex systems for trip solenoid interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat indicators are on the front panel?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures three LED indicators for critical diagnostic information including functional fault statuses.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47357744513282,"sku":"IS200VTURH1BAB","price":425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/IS200VTURH1BAB.jpg?v=1770864808","url":"https:\/\/www.nex-auto.com\/products\/is200vturh1bab-ge-mark-vi-vibration-transducer-interface-module","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}