{"product_id":"s30a-4111dp-sick-s3000-safety-laser-scanner-profinet","title":"S30A-4111DP SICK S3000 Safety Laser Scanner | PROFINET","description":"\u003ch2\u003e\u003cstrong\u003eS30A-4111DP SICK S3000 Safety Laser Scanner\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e SICK\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eS30A-4111DP\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003eS3000\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1045651\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective field range:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e4 m\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum warning field range:\u003c\/strong\u003e 49 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistance measuring range:\u003c\/strong\u003e 49 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan angle:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e190°\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 30 mm, 40 mm, 50 mm, 70 mm, 150 mm (configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e60 ms\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of simultaneously monitored protective fields:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of field sets:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of fields:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of monitoring cases:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of field set:\u003c\/strong\u003e Dual field sets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of multiple samplings:\u003c\/strong\u003e Configurable 2 to 16\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety and Network Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety integrity level:\u003c\/strong\u003e SIL2 (IEC 61508), SILCL2 (EN 62061)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Category 3 (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance level:\u003c\/strong\u003e PL d (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePFHd:\u003c\/strong\u003e 8.0 1E-08 (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMission time:\u003c\/strong\u003e 20 a (EN ISO 13849)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Type 3 (IEC 61496)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaser class:\u003c\/strong\u003e 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous area protection:\u003c\/strong\u003e Vertical and horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess protection:\u003c\/strong\u003e Vertical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePROFINET and PROFIsafe Properties\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFINET IO device:\u003c\/strong\u003e 2-port real-time switch per PROFINET specification V2.2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGSDML:\u003c\/strong\u003e According to GSDML specification V2.25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePROFIsafe profile:\u003c\/strong\u003e 6-octet input and 6-octet output per IEC 61784-3-3 V2.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCycle time:\u003c\/strong\u003e 4, 8, 16, 32 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformance:\u003c\/strong\u003e Conformance Class B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopology support:\u003c\/strong\u003e SNMP, MIB-2, LLDP per IEEE 802.1AB, MRP client support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort properties:\u003c\/strong\u003e Auto-negotiation, auto-crossover (MDIX), auto-polarity, 100Base-TX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch properties:\u003c\/strong\u003e Filtering data base per IEEE 802.1D, 6 prioritization levels for IEEE 802.1Q\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Channel diagnostics, report system errors, cable diagnostics, neighborhood alerts, port statistics, I\u0026amp;M0 to I\u0026amp;M4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot supported:\u003c\/strong\u003e Multicast communication, Supervisor AR, MAC-pause in full duplex, back-pressure in half duplex, static learning, broadcast storm control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Interface Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 16.8 V DC, 24 V DC, 28.8 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection class:\u003c\/strong\u003e III (VDE 0106, EN 60950)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration and diagnostics interface:\u003c\/strong\u003e RS-232\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCDS interfaces:\u003c\/strong\u003e TCP port 9000 and UDP port 30718\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical connection:\u003c\/strong\u003e Copper conductor, 2 female connectors for RJ-45 push-pull plug, system plug with or without connecting cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured data output:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated configuration memory:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic protective field switching:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal device monitoring (EDM):\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe SICK device communication via EFI\/SDL:\u003c\/strong\u003e Not supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical and Environmental Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 155 mm x 185 mm x 160 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.3 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure rating:\u003c\/strong\u003e IP 65 (EN 60529)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient operating temperature:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e–10 °C to +50 °C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the scanner indoors so the 190° scan angle fully covers the hazardous area.\u003c\/li\u003e\n\u003cli\u003eUse the RJ-45 push-pull connectors to link the device to your PROFINET network.\u003c\/li\u003e\n\u003cli\u003eSet the PROFIsafe cycle time to 4, 8, 16, or 32 ms to match your controller.\u003c\/li\u003e\n\u003cli\u003eConfigure resolution and multiple samplings according to your safety distance calculation.\u003c\/li\u003e\n\u003cli\u003eUse the RS-232 interface or CDS over TCP port 9000 for configuration and diagnostics.\u003c\/li\u003e\n\u003cli\u003eConfirm the 60 ms response time against your machine stopping time before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003eS30A-4111DP\u003c\/strong\u003e safety laser scanner\u003c\/li\u003e\n\u003cli\u003e1 x System plug\u003c\/li\u003e\n\u003cli\u003e1 x Mounting kit\u003c\/li\u003e\n\u003cli\u003e1 x Quick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock:\u003c\/strong\u003e We have this item in stock and ready for dispatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead time:\u003c\/strong\u003e We ship within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, and DHL are available for delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e We support 30-day returns for this product.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand new and original.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the protective field range of the S30A-4111DP?\u003c\/strong\u003e\u003cbr\u003eA: The protective field range is 4 m, and the maximum warning field range is 49 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model support PROFINET and PROFIsafe?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is a PROFINET IO device with PROFIsafe profile support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many protective fields can this scanner monitor simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: It can simultaneously monitor 2 protective fields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the response time of the S30A-4111DP?\u003c\/strong\u003e\u003cbr\u003eA: The response time is 60 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The ambient operating temperature range is –10 °C to +50 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does this model support external device monitoring?\u003c\/strong\u003e\u003cbr\u003eA: No, external device monitoring (EDM) is not supported on this model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What enclosure rating does this scanner have?\u003c\/strong\u003e\u003cbr\u003eA: The enclosure rating is IP 65.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\" rel=\"noopener\" target=\"_blank\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":50735931883778,"sku":"S30A-4111DP","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/S30A-4111DP.jpg?v=1791949798","url":"https:\/\/www.nex-auto.com\/products\/s30a-4111dp-sick-s3000-safety-laser-scanner-profinet","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}