{"product_id":"sj-e204l-keyence-bar-ionizer-static-eliminator","title":"SJ-E204L Keyence Bar Ionizer Static Eliminator","description":"\u003ch2\u003e\u003cstrong\u003eSJ-E204L Keyence Bar-Type Static Eliminator: Extended Reach for Wide Production Lines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Keyence\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eSJ-E204L\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e SJ-E series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Bar-type static eliminator (small flow model)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIon generation:\u003c\/strong\u003e Corona discharge with shockless resistive coupling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage application:\u003c\/strong\u003e Pulse AC method, ±8000 V applied voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIon balance control:\u003c\/strong\u003e Hi-Power I.C.C. method\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIon balance:\u003c\/strong\u003e \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003e±30 V\u003c\/strong\u003e\u003c\/span\u003e measured at 300 mm or more with 0.2 MPa air pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation distance:\u003c\/strong\u003e 50 to 2000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of electrodes:\u003c\/strong\u003e 33\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEffective length:\u003c\/strong\u003e \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003e2120 mm\u003c\/strong\u003e\u003c\/span\u003e static elimination range at 50 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal length:\u003c\/strong\u003e 2000 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode probe material:\u003c\/strong\u003e Tungsten\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain body material:\u003c\/strong\u003e ABS\/PBT\/PP\/LCP\/PPS\/SPS\/SUS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.10 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Control Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupply voltage ranges from \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003e24 to 36 VDC ±10%\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCurrent consumption reaches 700 mA at 24 V and 500 mA at 36 V\u003c\/li\u003e\n\u003cli\u003eOutputs use NPN open collector for ion level warning, condition warning, and alarm\u003c\/li\u003e\n\u003cli\u003eStatic elimination stop input accepts NPN open collector or contact point signals\u003c\/li\u003e\n\u003cli\u003eControl output handles NPN open collector with 100 mA maximum at 40 VDC or less\u003c\/li\u003e\n\u003cli\u003eAir connection port uses Rc 1\/8 thread\u003c\/li\u003e\n\u003cli\u003eAir supply pressure spans \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003e0.1 to 0.5 MPa\u003c\/strong\u003e\u003c\/span\u003e with 0.2 MPa recommended\u003c\/li\u003e\n\u003cli\u003eOvervoltage category I and pollution degree 2 apply\u003c\/li\u003e\n\u003cli\u003eBuilt-in communication ports remain unavailable; the unit supports remote control communication only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Tolerance and Interference Resistance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature holds steady from \u003cspan style=\"color: #1a5276;\"\u003e\u003cstrong\u003e0 to +40 °C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity ranges from 35 to 85 % RH without condensation\u003c\/li\u003e\n\u003cli\u003eThe shockless resistive coupling design suppresses discharge spikes and protects sensitive products\u003c\/li\u003e\n\u003cli\u003eHi-Power I.C.C. control corrects ion balance against environmental drift and interference\u003c\/li\u003e\n\u003cli\u003eThe product carries no formal protection rating, so install it in clean indoor areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the bar between 50 mm and 2000 mm from the target surface\u003c\/li\u003e\n\u003cli\u003eKeep the 33 tungsten electrodes free of dust and oil for stable corona discharge\u003c\/li\u003e\n\u003cli\u003eConnect clean, dry compressed air to the Rc 1\/8 port at 0.2 MPa for best results\u003c\/li\u003e\n\u003cli\u003eWire the 24 to 36 VDC supply and confirm the current draw stays within rated limits\u003c\/li\u003e\n\u003cli\u003eRoute the NPN open collector alarm output to your PLC or indicator for condition monitoring\u003c\/li\u003e\n\u003cli\u003eVerify ion balance with a charged plate monitor after installation and during scheduled checks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eSJ-E204L\u003c\/strong\u003e bar-type static eliminator\u003c\/li\u003e\n\u003cli\u003eMounting hardware and installation instructions\u003c\/li\u003e\n\u003cli\u003eProtective packaging for safe transport\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe keep this item in stock and ship within 5 days\u003c\/li\u003e\n\u003cli\u003eWe deliver through FedEx, UPS, and DHL\u003c\/li\u003e\n\u003cli\u003eWe accept returns within 30 days\u003c\/li\u003e\n\u003cli\u003eEvery unit arrives brand new and original\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What installation distance does the SJ-E204L support?\u003c\/strong\u003e\u003cbr\u003eA: The bar works from 50 mm to 2000 mm, and the 2120 mm effective range applies at 50 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How stable is the ion balance?\u003c\/strong\u003e\u003cbr\u003eA: The Hi-Power I.C.C. method holds balance at ±30 V when you measure at 300 mm or more with 0.2 MPa air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many electrodes does this bar carry?\u003c\/strong\u003e\u003cbr\u003eA: It uses 33 tungsten electrodes along a 2000 mm total length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which supply voltage does the unit need?\u003c\/strong\u003e\u003cbr\u003eA: It runs on 24 to 36 VDC ±10% and draws 700 mA at 24 V or 500 mA at 36 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What air pressure should I set?\u003c\/strong\u003e\u003cbr\u003eA: The range is 0.1 to 0.5 MPa, and Keyence recommends 0.2 MPa for rated performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The bar operates from 0 to +40 °C at 35 to 85 % RH without condensation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Keyence","offers":[{"title":"Default Title","offer_id":51003429355778,"sku":"SJ-E204L","price":208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/SJ-E204L.jpg?v=1794194472","url":"https:\/\/www.nex-auto.com\/products\/sj-e204l-keyence-bar-ionizer-static-eliminator","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}