{"product_id":"tc-fil081-honeywell-8-ch-thermocouple-input-analog-module","title":"TC-FIL081 Honeywell 8-Ch Thermocouple Input Analog Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell TC-FIL081 Thermocouple Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell TC-FIL081 (8-Channel Thermocouple Analog Input).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e The module provides 8 isolated thermocouple input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Thermocouple Types:\u003c\/strong\u003e B, C, E, J, K, N, R, S, T, and TXK\/XK (L) types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Ranges:\u003c\/strong\u003e Type B: 300 to 1820°C; Type C: 0 to 2315°C; Type E: -270 to 1000°C; Type J: -210 to 1200°C; Type K: -270 to 1372°C; Type N: -270 to 1300°C; Types R\/S: -50 to 1768°C; Type T: -270 to 400°C; TXK\/XK: -200 to 800°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit data format with typical 2.384 µV per bit resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e With filter at 24°C: ±0.5°C (0.025% of full scale); without filter: ±0.5°C (0.05% of full scale).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Rejection:\u003c\/strong\u003e Normal mode -60dB @ 60Hz; common mode -115dB @ 60Hz and -100dB @ 50Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Throughput:\u003c\/strong\u003e 325ms for 1 channel, 2.6s for 8 channels (programmable down to 28ms and 224ms respectively).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Bandwidth:\u003c\/strong\u003e 0 to 2.62Hz (-3dB) for stable signal acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRFI Immunity:\u003c\/strong\u003e Error less than 1% of range at 10V\/m from 27 to 1000MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e Built-in compensation range from 0 to 70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e 35V dc continuous and 250V peak transient withstand capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Detection:\u003c\/strong\u003e Automatically detects open thermocouples and outputs an upscale reading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Electrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Temperature:\u003c\/strong\u003e 0 to 55°C (32 to 131°F) with derating curve considerations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C (-40 to 185°F) for safe storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5 to 95% non-condensing (operating); 5 to 80% non-condensing (non-operating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30g peak acceleration (operating) and 50g (non-operating) with 11ms pulse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e Tested at 5g from 10 to 500Hz per IEC 68-2-6 standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24V dc nominal (range 19.2 to 31.2V dc including 5% ripple).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Current:\u003c\/strong\u003e Draws 150mA typical at 24V dc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 3W maximum at 31.2V dc; thermal dissipation 10.2 BTU\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexbus Current:\u003c\/strong\u003e Consumes 20mA from the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel-to-channel isolation of 10V for reliable signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e Certified for Class I Division 2 and Class I Zone 2 Group IIC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What thermocouple types does the TC-FIL081 support?\u003c\/strong\u003e\u003cbr\u003eA: It supports B, C, E, J, K, N, R, S, T, and TXK\/XK (L) types with full temperature ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the resolution of the TC-FIL081 module?\u003c\/strong\u003e\u003cbr\u003eA: The module provides 16-bit resolution with a typical step size of 2.384 µV per bit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the TC-FIL081 have built-in cold junction compensation?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes internal cold junction compensation for the range 0 to 70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the system throughput for 8 channels?\u003c\/strong\u003e\u003cbr\u003eA: The default scan time is 2.6 seconds for all 8 channels, programmable down to 224ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this module in a hazardous area?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is certified for Class I Division 2 and Class I Zone 2 Group IIC locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum input voltage the TC-FIL081 can withstand?\u003c\/strong\u003e\u003cbr\u003eA: It handles 35V dc continuous and 250V peak transients without damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have stock for the Honeywell TC-FIL081?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we maintain ample stock and ship within 5 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What shipping carriers do you use?\u003c\/strong\u003e\u003cbr\u003eA: We ship via FedEx, UPS, or DHL – you can select your preferred option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48264969453826,"sku":"TC-FIL081","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/TC-FIL081.jpg?v=1789897781","url":"https:\/\/www.nex-auto.com\/products\/tc-fil081-honeywell-8-ch-thermocouple-input-analog-module","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}