{"product_id":"tc-pbfo01-honeywell-controlnet-repeater-adapter-hazardous","title":"TC-PBFO01 Honeywell ControlNet Repeater Adapter Hazardous","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell TC-PBFO01 ControlNet Repeater Adapter for Hazardous Locations\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eFiber Module Capacity \u0026amp; Power Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eFiber Module Capacity:\u003c\/strong\u003e\u003c\/span\u003e 2 fiber modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eIntrinsically Safe Power Channel (Ui):\u003c\/strong\u003e\u003c\/span\u003e 9.5 Vdc, 1 A, Ci = 120 nF, Li negligible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/span\u003e One power supply unit load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003c\/span\u003e 8 W maximum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInternal \u0026amp; External Bus Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eInternal Bus (TTL):\u003c\/strong\u003e\u003c\/span\u003e Uo = 5.4 Vdc, Io = 201 mA, Po = 1.09 W, Lo ≤ 0.45 mH, Co = 71 μF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eExternal Bus (ControlNet):\u003c\/strong\u003e\u003c\/span\u003e Uo = 5.4 Vdc, Io = 201 mA, AC coupled with high-pass filter (f ≥ 900 kHz).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eCommunication Rate:\u003c\/strong\u003e\u003c\/span\u003e 5 Mbit\/s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003eGalvanic Isolation (per DIN EN 50020):\u003c\/strong\u003e\u003c\/span\u003e TTL Bus \/ Power Supply, TTL Bus \/ ControlNet, ControlNet \/ Power Supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental \u0026amp; Operating Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e\u003c\/span\u003e -20°C to 70°C (-4°F to 158°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/span\u003e -20°C to 100°C (-4°F to 212°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eMaximum Relative Humidity:\u003c\/strong\u003e\u003c\/span\u003e 95% non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003ePollution Gas Test:\u003c\/strong\u003e\u003c\/span\u003e Test Level G3 per ISA-S71.04-1985.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eShock Test:\u003c\/strong\u003e\u003c\/span\u003e 15g peak, 11ms duration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eVibration Test:\u003c\/strong\u003e\u003c\/span\u003e 2g @ 10 Hz to 500 Hz per IEC 68-2-6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eProtection Class:\u003c\/strong\u003e\u003c\/span\u003e IP20 (requires IP54 or better housing for field installation).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Dimensions \u0026amp; Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #8e44ad;\"\u003e\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e\u003c\/span\u003e 92 mm x 94 mm x 87 mm (3.6 in x 3.7 in x 3.4 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #8e44ad;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/span\u003e 0.319 kg (0.70 lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #8e44ad;\"\u003e\u003cstrong\u003eWire Size (Power Terminals):\u003c\/strong\u003e\u003c\/span\u003e 12 AWG (4 mm²) stranded max, 1.2 mm insulation max.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #8e44ad;\"\u003e\u003cstrong\u003eControlNet Cable:\u003c\/strong\u003e\u003c\/span\u003e Belden 3092A (see Honeywell specifications for details).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards \u0026amp; Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e67e22;\"\u003e\u003cstrong\u003eConformity:\u003c\/strong\u003e\u003c\/span\u003e DIN EN 50014:1992, DIN EN 50020:1994, DIN EN 50284:1997, DIN IEC 721, DIN EN 50081-2, DIN EN 50082-2, NAMUR NE 21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e67e22;\"\u003e\u003cstrong\u003eCE Conformity (Europe):\u003c\/strong\u003e\u003c\/span\u003e TBD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e67e22;\"\u003e\u003cstrong\u003eCENELEC Classification:\u003c\/strong\u003e\u003c\/span\u003e II (1) 2G EEx ia\/ib IIB\/IIC T4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e67e22;\"\u003e\u003cstrong\u003eATEX Certification:\u003c\/strong\u003e\u003c\/span\u003e DMT 99 ATEX E 036 X. Marked for all applicable directives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eHoneywell TC-PBFO01\u003c\/strong\u003e on a DIN rail inside a suitable enclosure.\u003c\/li\u003e\n\u003cli\u003eUse an IP54 or higher rated housing when installing in hazardous field locations.\u003c\/li\u003e\n\u003cli\u003eConnect the ControlNet cables using Belden 3092A coax per Honeywell specifications.\u003c\/li\u003e\n\u003cli\u003eInstall fiber optic modules into the two available slots as needed.\u003c\/li\u003e\n\u003cli\u003eEnsure all intrinsically safe connections comply with ATEX installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eHoneywell TC-PBFO01\u003c\/strong\u003e ControlNet repeater adapter.\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting clip (pre-installed).\u003c\/li\u003e\n\u003cli\u003ePrinted quick-start guide.\u003c\/li\u003e\n\u003cli\u003eNo certificates or warranty documents included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship via \u003cstrong\u003eFedEx, UPS, or DHL\u003c\/strong\u003e within 5 business days.\u003c\/li\u003e\n\u003cli\u003eAll units are brand new and original stock.\u003c\/li\u003e\n\u003cli\u003eWe keep the \u003cstrong\u003eTC-PBFO01\u003c\/strong\u003e in stock for immediate dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many fiber modules does the TC-PBFO01 support?\u003c\/strong\u003e\u003cbr\u003eThis \u003cstrong\u003eHoneywell TC-PBFO01\u003c\/strong\u003e supports up to 2 fiber optic modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the intrinsically safe power rating?\u003c\/strong\u003e\u003cbr\u003eThe IS power channel provides Ui = 9.5 Vdc and Ii = 1 A with Ci = 120 nF.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What communication rate does this repeater support?\u003c\/strong\u003e\u003cbr\u003eIt supports ControlNet at 5 Mbit\/s with a high-pass filter at 900 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this module certified for hazardous locations?\u003c\/strong\u003e\u003cbr\u003eYes, it carries ATEX certification DMT 99 ATEX E 036 X and CENELEC II (1) 2G EEx ia\/ib IIB\/IIC T4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What operating temperature range does it support?\u003c\/strong\u003e\u003cbr\u003eThe TC-PBFO01 operates from -20°C to 70°C (-4°F to 158°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have the TC-PBFO01 in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we maintain stock and ship within 5 days via FedEx, UPS, or DHL. Returns are accepted within 30 days.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-top: 20px;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48259502506242,"sku":"TC-PBFO01","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/TC-PBFO01.jpg?v=1786346294","url":"https:\/\/www.nex-auto.com\/products\/tc-pbfo01-honeywell-controlnet-repeater-adapter-hazardous","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}