{"product_id":"tc-pil081-honeywell-8-channel-temperature-input-module","title":"TC-PIL081 Honeywell 8-Channel Temperature Input Module","description":"\u003ch2\u003e\u003cstrong\u003eTC-PIL081 Honeywell Temperature Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eHoneywell TC-PIL081\u003c\/strong\u003e supports multiple TC sensor types including E, J, K, N, R, S, and T. The mV input range spans from –40 mV to 100 mV.\u003c\/li\u003e\n\u003cli\u003eRTD support covers Pt100, Pt200, Ni100, Ni200, Ni120, and Cu10 sensor types. The module offers 2-wire, 3-wire, and 4-wire measurement modes.\u003c\/li\u003e\n\u003cli\u003eYou can configure temperature formats as Celsius, Fahrenheit, or Kelvin for all channels. Filter cutoff frequencies range from 0.2 Hz to 10 Hz per group.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eTC-PIL081\u003c\/strong\u003e delivers 16-bit resolution with a 4 ms response time. Thermocouple accuracy reaches ±0.5% for types E, J, K, and N.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIntrinsic Safety and Electrical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis module carries a CENELEC II (1) 2G EEx ia\/ib IIB\/IIC T4 certification. Permissible field values include Uo = 9V, Io = 37mA, and Po = 83mW.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eTC-PIL081\u003c\/strong\u003e provides galvanic isolation between inputs and the backplane bus. It also isolates inputs from the power supply per DIN EN 50020 standards.\u003c\/li\u003e\n\u003cli\u003ePower consumption measures 0.19 power supply unit load with 1.6W power dissipation. Input voltage supplies through the intrinsically safe terminal base.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAlarm and Fault Detection Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module enables configurable fault detection for lead breakage or short circuits. You can set this feature independently for channel groups 0 to 3 and 4 to 7.\u003c\/li\u003e\n\u003cli\u003eOverrange and underrange alarms activate per individual channel. A cold junction alarm monitors the reference junction health.\u003c\/li\u003e\n\u003cli\u003eCold junction sensor accuracy reaches ±0.8°C maximum at 25°C. Drift performance stays within 100ppm\/°C across the -15°C to 70°C range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature spans –20°C to 70°C with storage capability from –20°C to 100°C. Maximum relative humidity tolerates 95% non-condensing conditions.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eTC-PIL081\u003c\/strong\u003e withstands 15g peak shock with 11ms duration. Vibration tolerance meets 2g @ 10Hz to 500Hz per IEC 68-2-6 standards.\u003c\/li\u003e\n\u003cli\u003eProtection class is IP20, requiring a separate IP54 or better housing for field installations. Dimensions measure 76 x 94 x 46 mm and weight is 0.247 kg.\u003c\/li\u003e\n\u003cli\u003eKeyswitch position is 2. The module meets EMC compliance through DIN EN 50081-2, DIN EN 50082-2, and NAMUR NE 21 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the TC-PIL081 handle both thermocouples and RTDs simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYes, you can configure channels 0 to 3 for one sensor type and channels 4 to 7 for another type. Each group operates independently with its own filter setting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the TC-PIL081 support 4-wire RTD measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYes, the module supports 2-wire, 3-wire, and 4-wire RTD configurations. The 4-wire mode eliminates lead resistance errors for maximum accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during a sensor lead breakage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe module detects open circuits when fault detection is enabled. You will see a fault alarm for the affected channel group.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TC-PIL081 suitable for hazardous area installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYes, it carries CENELEC II (1) 2G EEx ia\/ib IIB\/IIC T4 certification for intrinsic safety. Always follow field circuit values for safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the shipping and return policies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWe keep all items in stock and ship within 5 business days. We use DHL, FedEx, and UPS for fast delivery. We accept returns within 30 days of receipt.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/wa.me\/861539249628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48264908931330,"sku":"TC-PIL081","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/TC-PIL081.jpg?v=1786959592","url":"https:\/\/www.nex-auto.com\/products\/tc-pil081-honeywell-8-channel-temperature-input-module","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}