{"product_id":"tc-pob041-honeywell-4-point-digital-output-module","title":"TC-POB041 Honeywell 4-Point Digital Output Module","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell TC-POB041 4-Point Digital Output Module Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Capacity:\u003c\/strong\u003e 4 output channels share a single supply reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety:\u003c\/strong\u003e Europe: II (1) 2G EEx ia\/ib IIB\/IIC T4 (CENELEC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Functional Data:\u003c\/strong\u003e Delivers 11V at 45mA per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFailure State:\u003c\/strong\u003e Defaults to a de-energized state upon fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Offers a 1ms delay for all 4 channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e Supports up to 10kHz operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Circuit Values (Uo\/Io):\u003c\/strong\u003e Uo = 27.4V, Io = 110mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductance (Lo):\u003c\/strong\u003e 8mH max for EEx ia IIB, 2mH max for EEx ia IIC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance (Co):\u003c\/strong\u003e 677nF max for EEx ia IIB, 87nF max for EEx ia IIC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e Uses one power supply unit load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e Maximum 5W power dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Detection:\u003c\/strong\u003e Detects lead breakage and short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Indication:\u003c\/strong\u003e Sends an alarm via backplane Bus and flashes red LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLatch Mode:\u003c\/strong\u003e Configurable latch mode applies to all channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Isolates output from backplane bus and power supply per DIN EN 50020.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Physical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e Operates from –20°C to 70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e Withstands –20°C to 100°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e Handles 95% relative humidity, non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Gas Test:\u003c\/strong\u003e Meets Test Level G3 per ISA-S71.04-1985.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Test:\u003c\/strong\u003e Withstands 15g peak for 11ms duration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Test:\u003c\/strong\u003e Endures 2g @ 10Hz to 500Hz per IEC 68-2-6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 (requires IP54 housing for field installation).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Lightweight at 0.282 kg (0.62 lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (HxWxD):\u003c\/strong\u003e 76 x 94 x 46 mm (3.0 x 3.7 x 1.8 inches).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyswitch Position:\u003c\/strong\u003e Position 7 for easy configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission:\u003c\/strong\u003e Uses a Vendor Specific Bus for intrinsically safe input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e Receives intrinsically safe power through the Terminal Base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e Conforms to DIN EN 50014:1992, DIN EN 50020:1994, and DIN EN 50284:1997.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClimatic Conditions:\u003c\/strong\u003e Designed per DIN IEC 721 specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Compatibility:\u003c\/strong\u003e Meets DIN EN 50081-2, DIN EN 50082-2, and NAMUR NE 21.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Conformity:\u003c\/strong\u003e Requires shielded multicore cable for EMC protection class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Certification:\u003c\/strong\u003e Holds CENELEC DMT 99 ATEX E 026 classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage and Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Ships in original factory packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e 100% brand new and original stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e We ship within 5 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e We use FedEx, UPS, and DHL for delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e We support a 30-day return policy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the Honeywell TC-POB041 a new original module?\u003c\/strong\u003e Yes, we supply 100% brand new and original \u003cstrong\u003eTC-POB041\u003c\/strong\u003e modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the response time of the TC-POB041?\u003c\/strong\u003e The module offers a fast 1ms input\/output delay for all four channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes the TC-POB041 support fault detection?\u003c\/strong\u003e Yes, it detects lead breakage and short circuits with a configurable delay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum switching frequency?\u003c\/strong\u003e The \u003cstrong\u003eTC-POB041\u003c\/strong\u003e supports a switching frequency of up to 10kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the field circuit output values?\u003c\/strong\u003e The Uo is 27.4V and Io is 110mA for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo you have the TC-POB041 in stock?\u003c\/strong\u003e Yes, we maintain the \u003cstrong\u003eTC-POB041\u003c\/strong\u003e in stock for prompt shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the shipping time for orders?\u003c\/strong\u003e We dispatch all orders within 5 business days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich couriers do you use for shipping?\u003c\/strong\u003e We ship using FedEx, UPS, or DHL for reliable delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved. \u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48264926396674,"sku":"TC-POB041","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/TC-POB041.jpg?v=1786960341","url":"https:\/\/www.nex-auto.com\/products\/tc-pob041-honeywell-4-point-digital-output-module","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}