{"product_id":"temperature-monitor-bently-nevada-3500-61-01-02","title":"Temperature Monitor Bently Nevada 3500\/61-01-02","description":"\u003ch2\u003e\n\u003cstrong\u003eBently Nevada 3500\/61-01-02\u003c\/strong\u003e Temperature Monitor with Recorder Outputs\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cspan style=\"color: #cc0000;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong\u003e3500\/61-01-02\u003c\/strong\u003e temperature monitor\u003c\/span\u003e for 3500 series monitoring systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Temperature monitor with recorder outputs. I\/O Type: RTD\/TC non-isolated with internal terminations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e 02 = ATEX, IECEx, CSA (Class I, Zone 2).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 9 watts nominal for 3500\/61 model.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e 10 MOhms for each lead input.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNumber of inputs:\u003c\/strong\u003e Accepts 1 to 6 RTD or TC transducer signals.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecorder outputs:\u003c\/strong\u003e 4 to 20 mA proportional to full scale. Load range 0 to 600 Ohms.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.3662 microamps per bit. Accuracy ±0.15% at room temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eThermocouple (TC) Input Ranges\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType E:\u003c\/strong\u003e -100 to +1000 degrees Celsius (-148 to +1832 degrees Fahrenheit).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType J:\u003c\/strong\u003e -18 to +760 degrees Celsius (0 to +1400 degrees Fahrenheit).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType K:\u003c\/strong\u003e -18 to +1370 degrees Celsius (0 to +2498 degrees Fahrenheit).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType T:\u003c\/strong\u003e -160 to +400 degrees Celsius (-256 to +752 degrees Fahrenheit).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType E restriction:\u003c\/strong\u003e Above +35°C ambient, range reduces to -60 to +1000°C. Do not configure below -60°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRTD Input Ranges\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePlatinum RTD (alpha 0.00385):\u003c\/strong\u003e -200 to +850°C (-328 to +1562°F). Worldwide industrial standard. Recommended for all applications.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePlatinum RTD (alpha 0.00392):\u003c\/strong\u003e -200 to +700°C (-328 to +1292°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNickel RTD (120 Ohm):\u003c\/strong\u003e -80 to +260°C (-112 to +500°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCopper RTD (10 Ohm):\u003c\/strong\u003e -100 to +260°C (-148 to +500°F). Resolution 1°C. Accuracy ±3°C at 25°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eI\/O Module Details\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eI\/O Type:\u003c\/strong\u003e 01 = RTD\/TC non-isolated I\/O module with internal terminations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem isolation:\u003c\/strong\u003e 500 Vdc. Channel to channel isolation: 250 Vdc.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRTD current source:\u003c\/strong\u003e 925 ±15 microamps at 25°C per transducer.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecorder voltage compliance:\u003c\/strong\u003e 0 to +12 Vdc across load.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShort circuit protection:\u003c\/strong\u003e Monitor operation unaffected by recorder output shorts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAccuracy Specifications\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInternal termination non-isolated:\u003c\/strong\u003e ±3°C at 25°C (±5.4°F at 77°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExternal termination non-isolated (standard rack):\u003c\/strong\u003e ±1°C at 25°C (±1.8°F at 77°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInternal termination isolated (standard rack):\u003c\/strong\u003e ±3°C at 25°C (±5.4°F at 77°F).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExternal termination isolated (bulkhead or standard rack):\u003c\/strong\u003e ±1°C at 25°C (±1.8°F at 77°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFront Panel Indicators\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOK LED:\u003c\/strong\u003e Indicates when temperature monitor operates properly.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTX\/RX LED:\u003c\/strong\u003e Indicates communication with other rack modules.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBypass LED:\u003c\/strong\u003e Indicates when monitor is in bypass mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEnvironmental Limits\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating with internal\/external termination:\u003c\/strong\u003e -30 to +65 degrees Celsius (-22 to +150 degrees Fahrenheit).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating with internal barrier I\/O:\u003c\/strong\u003e 0 to +65 degrees Celsius (32 to +150 degrees Fahrenheit).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40 to +85 degrees Celsius (-40 to +185 degrees Fahrenheit).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePhysical Dimensions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMonitor module:\u003c\/strong\u003e 241.3 x 24.4 x 241.8 mm, 0.91 kg. One full-height front slot.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eI\/O module (standard):\u003c\/strong\u003e 241.3 x 24.4 x 99.1 mm, 0.45 kg. One full-height rear slot.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eI\/O module (internal barrier):\u003c\/strong\u003e 241.3 x 24.4 x 163.1 mm, 0.46 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHazardous Area Approvals\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for European explosive atmospheres.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e International certification for worldwide use.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I, Zone 2 certified for North America.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Refineries, chemical plants, gas pipelines, offshore platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e3500\/61-01-02 temperature monitor module.\u003c\/li\u003e\n    \u003cli\u003eRTD\/TC non-isolated I\/O module with internal terminations.\u003c\/li\u003e\n    \u003cli\u003eDocumentation and installation guide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping Information\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 1.36 kg (3.0 lb) combined.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Factory sealed boxes.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL (2 to 5 business days).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between 3500\/60 and 3500\/61?\u003c\/strong\u003e\u003cbr\u003e\n    A: 3500\/60 consumes 7 watts nominal. 3500\/61 consumes 9 watts nominal. Both accept 1 to 6 RTD or TC inputs. The 3500\/61 includes recorder outputs (4 to 20 mA).\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What does non-isolated I\/O module mean?\u003c\/strong\u003e\u003cbr\u003e\n    A: Non-isolated I\/O modules do not provide channel to channel isolation. Isolated modules (options -03 or -04) provide 250 Vdc channel isolation. Isolation only matters during fault scenarios.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What is the accuracy for copper RTD?\u003c\/strong\u003e\u003cbr\u003e\n    A: Copper RTD has 1°C resolution with ±3°C accuracy at 25°C. For higher accuracy applications, use platinum RTD (alpha 0.00385) which provides better performance.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: Can I use Type E thermocouples in high ambient temperatures?\u003c\/strong\u003e\u003cbr\u003e\n    A: Above +35°C ambient, the range reduces to -60 to +1000°C. The software allows configuration down to -100°C, but the system will not function properly. Do not configure below -60°C.\u003c\/li\u003e\n    \n    \u003cli\u003e\n\u003cstrong\u003eQ: What rack space does this monitor require?\u003c\/strong\u003e\u003cbr\u003e\n    A: Monitor module needs one full-height front slot. I\/O module needs one full-height rear slot. For internal barrier I\/O modules, depth is 163.1 mm vs standard 99.1 mm.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47635650576642,"sku":"3500\/61-01-02","price":321.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500_61-01-02.jpg?v=1775714959","url":"https:\/\/www.nex-auto.com\/products\/temperature-monitor-bently-nevada-3500-61-01-02","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}