{"product_id":"v18345-1027420001-abb-tzidc-positioner-double-acting-ex-ib","title":"V18345-1027420001 ABB TZIDC Positioner Double Acting Ex ib","description":"\u003ch2\u003e\u003cstrong\u003eABB V18345-1027420001 TZIDC Electro-Pneumatic Valve Positioner\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eV18345-1027420001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e TZIDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Electro-Pneumatic Positioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase \/ Mounting:\u003c\/strong\u003e Aluminium, varnished, IP 65 (NEMA 4X); linear per DIN\/IEC 534 \/ NAMUR, rotary per VDI\/VDE 3845, ready for integral mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput \/ Communication:\u003c\/strong\u003e 4...20 mA, two-wire with connector plug for LKS adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion Protection:\u003c\/strong\u003e GOST Russia Ex II 2 G EEx ib II C T6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput \/ Safe Position:\u003c\/strong\u003e Double acting, fail safe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Cable thread 1\/2-14 NPT; air pipe thread 1\/4-18 NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption Modules:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Kit:\u003c\/strong\u003e Without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign:\u003c\/strong\u003e Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (D x W x H):\u003c\/strong\u003e 16.85 cm x 9.29 cm x 8.95 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.70 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Two-wire technology, nominal range 4...20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit Range:\u003c\/strong\u003e Configurable between 20 % and 100 % of the nominal range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Rating:\u003c\/strong\u003e 25 mA \/ 30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Current:\u003c\/strong\u003e 3.4 mA without analog position feedback; 3.5 mA with analog position feedback\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart Value:\u003c\/strong\u003e Starts from 3.8 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Voltage at 20 mA:\u003c\/strong\u003e 8.7 V DC without explosion protection; 9.7 V DC for intrinsically safe device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance at 20 mA:\u003c\/strong\u003e 435 ohms without explosion protection; 485 ohms for intrinsically safe device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Input:\u003c\/strong\u003e Control voltage 24 V DC (12...30 V DC); logical \"0\" at 0...10 V DC; logical \"1\" at 12...30 V DC; current max. 4 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e Control circuit to DIN 19234 \/ NAMUR, supply voltage 5...11 V DC; current \u0026lt; 1.0 mA for logical \"0\"; current \u0026gt; 2.0 mA for logical \"1\"; effective direction configurable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e 0...6 bar (0...90 psi)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Capacity at 1.4 bar (20 psi):\u003c\/strong\u003e 5.0 kg\/h = 3.9 Nm³\/h = 2.3 scfm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Capacity at 6 bar (90 psi):\u003c\/strong\u003e 13 kg\/h = 10 Nm³\/h = 6.0 scfm (booster on request)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Function:\u003c\/strong\u003e For single or double acting actuators; air vents from the actuator or the actuator blocks in case of electrical power failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut-Off Values:\u003c\/strong\u003e End position 0 % = 0...45 %; end position 100 % = 55...100 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTravel and Positioning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAngle of Rotation:\u003c\/strong\u003e 25...120 ° for rotary actuators, optionally 270 °; 25...60 ° for linear actuators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTravel Limit:\u003c\/strong\u003e Min. and max. limits freely configurable within 0...100 % of total travel, min. range above 20 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTravel Time Prolongation:\u003c\/strong\u003e Range of 0...200 seconds, separately for each direction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning Time Limit:\u003c\/strong\u003e Range 0...200 seconds, monitoring parameter for control until the deviation reaches the tolerance band\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the actuator type first. Use DIN\/IEC 534 or NAMUR for linear actuators.\u003c\/li\u003e\n\u003cli\u003eUse VDI\/VDE 3845 for rotary actuators. Confirm the mounting kit fits your actuator.\u003c\/li\u003e\n\u003cli\u003eConnect the air pipe to the 1\/4-18 NPT port. Keep supply air clean and dry.\u003c\/li\u003e\n\u003cli\u003eConnect the cable through the 1\/2-14 NPT entry. Use shielded cable for the 4...20 mA loop.\u003c\/li\u003e\n\u003cli\u003eVerify the double-acting fail-safe output before pressurizing the system.\u003c\/li\u003e\n\u003cli\u003eRespect the explosion protection requirements in the hazardous area.\u003c\/li\u003e\n\u003cli\u003eConfigure the split range, travel limits, and travel time after calibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × ABB \u003cstrong\u003eV18345-1027420001\u003c\/strong\u003e TZIDC Electro-Pneumatic Positioner\u003c\/li\u003e\n\u003cli\u003e1 × Mounting hardware set for linear, rotary, or integral mounting\u003c\/li\u003e\n\u003cli\u003e1 × Quick installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship with FedEx, UPS, and DHL. Choose the carrier that fits your schedule.\u003c\/li\u003e\n\u003cli\u003eWe keep this model in stock and dispatch within 5 days after order confirmation.\u003c\/li\u003e\n\u003cli\u003eWe accept returns within 30 days. The unit must remain in its original condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the ABB V18345-1027420001 brand new and original?\u003c\/strong\u003e\u003cbr\u003eYes. We supply brand new original units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the safe position when power fails?\u003c\/strong\u003e\u003cbr\u003eThis version uses a double-acting output with fail safe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this positioner carry explosion protection?\u003c\/strong\u003e\u003cbr\u003eYes. It carries GOST Russia Ex II 2 G EEx ib II C T6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this version include analog position feedback?\u003c\/strong\u003e\u003cbr\u003eNo. This version ships without option modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I mount it on a rotary actuator?\u003c\/strong\u003e\u003cbr\u003eYes. It follows VDI\/VDE 3845 for rotary actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the angle of rotation range?\u003c\/strong\u003e\u003cbr\u003eIt is 25...120 ° for rotary actuators, optionally 270 °. For linear actuators, it is 25...60 °.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the supply pressure range?\u003c\/strong\u003e\u003cbr\u003eThe output range is 0...6 bar (0...90 psi).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the air and cable connection threads?\u003c\/strong\u003e\u003cbr\u003eAir pipe thread is 1\/4-18 NPT. Cable thread is 1\/2-14 NPT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow much does the unit weigh?\u003c\/strong\u003e\u003cbr\u003eThe unit weighs 1.70 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the unit dimensions?\u003c\/strong\u003e\u003cbr\u003eThe dimensions are 16.85 cm x 9.29 cm x 8.95 cm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved. Original Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e Contact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48475731165442,"sku":"V18345-1027420001","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/V18345-1027420001.jpg?v=1789093007","url":"https:\/\/www.nex-auto.com\/products\/v18345-1027420001-abb-tzidc-positioner-double-acting-ex-ib","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}