{"product_id":"xnx-amav-nhic1-honeywell-universal-gas-transmitter","title":"XNX-AMAV-NHIC1 Honeywell Universal Gas Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eXNX-AMAV-NHIC1 — Honeywell Universal Gas Transmitter for Reliable CO2 Detection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eXNX-AMAV-NHIC1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e XNX Universal Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 to 5 percent volume carbon dioxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e 3 Hz update rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 0.05 percent volume shift detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±0.3 percent deviation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.01 percent volume\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -40°C to +65°C (sensor dependent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 20 to 90 percent RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e NEMA 4X IP66 rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference Immunity:\u003c\/strong\u003e High ambient light rejection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e4-20 mA with HART protocol\u003c\/span\u003e as standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 18 to 32 VDC (IR units)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 9.7 watts (point IR sensor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Accuracy:\u003c\/strong\u003e ±1 percent full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e LM25 aluminum with marine-grade paint\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entries:\u003c\/strong\u003e Three M25 threaded ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Interface:\u003c\/strong\u003e Built-in HART connection port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Ratings:\u003c\/strong\u003e ATEX, IECEx, and INMETRO certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat gas does this model detect?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eXNX-AMAV-NHIC1\u003c\/strong\u003e measures carbon dioxide from 0 to 5 percent volume using an infrared sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this transmitter explosion-proof?\u003c\/strong\u003e\u003cbr\u003eYes, it carries ATEX and IECEx certifications for hazardous area installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat output signal does it provide?\u003c\/strong\u003e\u003cbr\u003eIt delivers a 4-20 mA signal with HART protocol for integration with control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eThe transmitter operates from -40°C to +65°C, depending on the connected sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I configure the transmitter?\u003c\/strong\u003e\u003cbr\u003eYou can use the built-in HART port with a handheld configurator or the magnetic wand interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the power requirement?\u003c\/strong\u003e\u003cbr\u003eIR units need 18 to 32 VDC and consume approximately 9.7 watts during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this unit come with certifications?\u003c\/strong\u003e\u003cbr\u003eYes, it includes ATEX, IECEx, and INMETRO approvals for hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the device in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we carry this model as brand new original stock ready for immediate dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 12px; color: #666;\"\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48539324154114,"sku":"XNX-AMAV-NHIC1","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-AMAV-NHIC1.jpg?v=1790046104","url":"https:\/\/www.nex-auto.com\/products\/xnx-amav-nhic1-honeywell-universal-gas-transmitter","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}