{"product_id":"xnx-utse-nnnnn-honeywell-transmitter-stainless-steel-ul-csa","title":"XNX-UTSE-NNNNN Honeywell Transmitter Stainless Steel UL\/CSA","description":"\u003ch2\u003e\u003cstrong\u003eXNX-UTSE-NNNNN Honeywell Stainless Steel Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNX-UTSE-NNNNN\u003c\/strong\u003e – XNX Series Stainless Steel Transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4-20mA analog with HART® digital communication overlay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e Configured for Honeywell XNX toxic and oxygen sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Material:\u003c\/strong\u003e Rugged stainless steel for superior corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Entries:\u003c\/strong\u003e Four 3\/4\" NPT conduit openings for easy field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL\/CSA certified for North American hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Depends on the installed XNX sensor (0-100% LEL, ppm, or %VOL).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e T90 response time typically under 30 seconds for most gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e High sensitivity down to 1 ppm for many toxic gas types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ±2% of full scale across the entire measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1 ppm or 0.1% LEL depending on sensor configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -40°C to +70°C for reliable outdoor and indoor use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e IP66\/IP67 rated against dust and water ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e Excellent resistance to RFI\/EMI interference per EN 61000-6-2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this transmitter compatible with my existing XNX sensors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNX-UTSE-NNNNN\u003c\/strong\u003e works with all Honeywell XNX toxic and oxygen sensor heads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum cable distance for the 4-20mA loop?\u003c\/strong\u003e\u003cbr\u003eA: You can run up to 1000 meters using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this transmitter in a Zone 1 hazardous area?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the UL\/CSA certification covers Class I, Division 1 groups B, C, D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the unit support HART® multivariable data?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the HART® protocol provides digital process variable and diagnostic data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I perform a zero calibration?\u003c\/strong\u003e\u003cbr\u003eA: Apply zero gas (nitrogen or clean air) and use the magnetic switch or HART®.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the warranty period for this product?\u003c\/strong\u003e\u003cbr\u003eA: We offer a 30-day return policy and full manufacturer's warranty coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is there a display option for local reading?\u003c\/strong\u003e\u003cbr\u003eA: This model does not include a display; it relies on the 4-20mA\/HART® output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I clean the stainless steel housing?\u003c\/strong\u003e\u003cbr\u003eA: Use a soft cloth with mild detergent; avoid abrasive or acidic cleaners.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/861539249628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48375122690306,"sku":"XNX-UTSE-NNNNN","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNX-UTSE-NNNNN.jpg?v=1787624173","url":"https:\/\/www.nex-auto.com\/products\/xnx-utse-nnnnn-honeywell-transmitter-stainless-steel-ul-csa","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}