{"product_id":"xnxr1ss-honeywell-sensor-hcl-0-10ppm-replacement","title":"XNXR1SS Honeywell Sensor HCl 0-10ppm Replacement","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXR1SS Replacement Sensor Cell\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Honeywell \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e Replacement Sensor Cell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Category:\u003c\/strong\u003e Electrochemical Gas Sensor Replacement Cell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Gas:\u003c\/strong\u003e Hydrogen Chloride (HCl)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 to 10 ppm (standard operating range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Setpoint Range:\u003c\/strong\u003e 10.0 to 20.0 ppm (adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 1.0 ppm for precise low-level detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for Honeywell XNX universal transmitter series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type:\u003c\/strong\u003e Electrochemical cell for selective HCl response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 3 Kg (includes protective packaging)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Replacement Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis sensor cell directly replaces the existing cell in your XNX transmitter housing.\u003c\/li\u003e\n\u003cli\u003eTurn off power to the transmitter before performing any sensor replacement.\u003c\/li\u003e\n\u003cli\u003eRemove the old sensor cell carefully from its socket inside the XNX enclosure.\u003c\/li\u003e\n\u003cli\u003eInsert the new \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e cell into the same socket with proper orientation.\u003c\/li\u003e\n\u003cli\u003eRecalibrate the transmitter after installation following Honeywell standard procedures.\u003c\/li\u003e\n\u003cli\u003eAllow sufficient warm-up time for the new sensor to stabilize before use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e replacement electrochemical sensor cell\u003c\/li\u003e\n\u003cli\u003eProtective shipping container with desiccant pack\u003c\/li\u003e\n\u003cli\u003eInstallation instruction sheet\u003c\/li\u003e\n\u003cli\u003eCalibration certificate (stored separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which transmitter does this sensor work with?\u003c\/strong\u003e\u003cbr\u003eA: This sensor cell is compatible with the Honeywell XNX series universal transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the detection range for this sensor?\u003c\/strong\u003e\u003cbr\u003eA: It detects Hydrogen Chloride from 0 to 10 ppm, with alarm settings from 10.0 to 20.0 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this sensor a direct replacement for my existing one?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eXNXR1SS\u003c\/strong\u003e is a direct drop-in replacement for the XNX series sensor cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Do you have this item in stock?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we maintain stock of this sensor. We ship within 5 business days after order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a brand new and original Honeywell product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we guarantee all products are brand new and original from Honeywell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which carriers do you use for shipping?\u003c\/strong\u003e\u003cbr\u003eA: We ship globally via major international couriers such as DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is your return policy?\u003c\/strong\u003e\u003cbr\u003eA: We accept returns within 30 days of receipt, provided the product remains unused and in original condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 NexAuto Technology Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.nex-auto.com\/\"\u003ehttps:\/\/www.nex-auto.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@nex-auto.com\"\u003esales@nex-auto.com\u003c\/a\u003e\u003cbr\u003ePhone: \u003ca href=\"https:\/\/wa.me\/8615392429628\"\u003e+86 153 9242 9628\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48381655449858,"sku":"XNXR1SS","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/XNXR1SS.jpg?v=1787713064","url":"https:\/\/www.nex-auto.com\/products\/xnxr1ss-honeywell-sensor-hcl-0-10ppm-replacement","provider":"NexAuto Technology Limited","version":"1.0","type":"link"}