GE IS215UCVDH7AM Mark VI Input Module Board
Bulk Orders & Fast Shipping
Instant 10% Discount On Winter Banks Credit/Debit Cards EMI and CreditCard
Fast & Reliable Worldwide Shipping – Ready to Dispatch from Stock
- Fast shipping
- Return Policy
- Lowest Price
- Help Center 24/7
-
Vendor:
General Electric
-
Type:
Terminal Board
- Tags Terminal board
About the Product
Core Specifications: GE IS215UCVDH7AM
- Brand & Model: General Electric IS215UCVDH7AM — authentic Mark VI Speedtronic series board.
- Manufacturer: GE Industrial Systems (Salem, Virginia USA).
- Product Type: Input Module Board. Functional acronym UCVD.
- Series: Mark VI Speedtronic Turbine Control System.
- PCB Protection: Full conformal coating. Thin chemically applied layer protects all components.
- Functional Revisions: Dual revisions — 1A and 2M. Modified version of parent IS215UCVDH7 board.
- Group: Group 7 Mark VI Series classification.
Diagnostic LED Indicators
- Front Faceplate LEDs: Six status indicators for controller and communication health.
- ACTIVE: Board operational status.
- BMAS: Backup master status.
- SLOT1: Slot identification indicator.
- ENET: Ethernet link status.
- SYS: System health monitor.
- BSLV: Backup slave status.
- Runtime Error Codes: Ten H/L LEDs. Display specific runtime error codes during operation.
- Diagnostic Value: Technicians read these LEDs instantly. No software needed for basic fault identification.
Connectivity & Communication Ports
- Monitor Port: GE-designated port. Factory use only.
- Mouse Port: GE-designated port. Not for field peripheral connection.
- Keyboard Port: GE-designated port. Reserved for manufacturer access.
- COM1: RS-232C serial port. Use for initial controller setup.
- COM2: RS-232C serial port. Handles serial communications during operation.
- Ethernet Port: Supports UDH (Unit Data Highway) communications. Primary data link.
- ISBus Drive LAN Ports: Physically present. Unused in standard Mark VI configurations.
Hardware Protection & PCB Coating
- Conformal Coating: Factory-applied thin chemical layer. Covers entire board surface.
- Protection Scope: Shields LEDs, ports, ICs, and passive components.
- Environmental Resistance: Guards against moisture, dust, vibration, and conductive contaminants.
- Inspection: Coating is transparent. All component labels and LEDs remain visible.
- Durability: Extends PCB service life in turbine control environments.
Functional Revision & Product Lineage
- Parent Board: Derived from IS215UCVDH7. The AM variant includes two functional revisions.
- Revision 1A: Base functional revision.
- Revision 2M: Secondary functional revision. Modifies parent board behavior.
- Modification Benefit: Offers enhanced compatibility or corrected errata from original H7 design.
- Documentation: Original GE factory manuals available. Functional description remains Input Module Board.
Mechanical & Physical Characteristics
- Form Factor: Mark VI standard module size. Fits dedicated UCVD slot.
- Faceplate: Front panel with cutouts for all LEDs and ports.
- Mounting: Rack-mounted within Mark VI control cabinet.
- PCB Layering: Multi-layer surface mount design.
- Country of Origin: United States. GE Industrial Systems, Salem VA.
Shipping & Availability
- Stock Status: In stock and ready to ship.
- Carriers: FedEx, UPS, DHL.
- Packaging: Anti-static ESD bag. Foam-lined industrial box.
- What You Receive: 1x GE IS215UCVDH7AM Input Module Board. No cables or mounting hardware included.
Frequently Asked Questions (FAQ)
1. What is the difference between IS215UCVDH7 and IS215UCVDH7AM?
The AM variant carries two functional revisions: 1A and 2M. The parent H7 board typically carries a single revision. The AM version also includes specific component updates verified during Salem production.
2. Can I use the mouse, keyboard, and monitor ports?
No. GE designates these ports for factory use only. They do not function as standard peripheral interfaces in the field. Use COM1 and COM2 for setup and serial tasks.
3. What do the ten H/L runtime LEDs tell me?
They display numeric error codes. Each H/L combination represents a specific runtime fault. Refer to GEH-6721 manual series for code translation.
4. Is the ISBus Drive LAN port required for operation?
No. Original GE documentation states these ports remain unused. You do not need to connect them. The ethernet port handles all UDH communications.
5. How do I verify conformal coating integrity?
Perform a visual inspection under bright light. The coating should appear uniform and glossy. No bare pads or lifted areas. No flaking or peeling at connector edges.
6. Buying advice: Should I choose the H7AM revision over older UCVD boards?
Yes. The IS215UCVDH7AM includes both revision A and M updates. It is the most current UCVD variant for Mark VI systems. It resolves known issues from early H7 production runs. Always verify your system group compatibility, but this board suits most Mark VI turbine retrofit projects.
Quick Quotes & Info
- Quick Quotes: Receive pricing and availability fast from our dedicated customer service team.
- Delivery: Expedited, freight, and international shipping available worldwide.
- Warranty: NexAuto offers a 12-month warranty on all parts purchased from us, in addition to any manufacturer coverage.
- Returns: 30-day return policy for defective or mismatched parts, ensuring peace of mind.
- Payment: Flexible options including major credit cards, PayPal, and bank transfers.
- Custom Calibration: Provide your specifications, and we’ll handle the rest with precision.

Industrial Electrical Solutions
Comprehensive Automation Equipment for Every Facility
PLCs, HMIs, Servo Drives, Sensors, and Cables for reliable operations.
BENTLEY NEVADA
Condition Monitoring Solutions
Proximity probes, sensors, and monitoring systems to protect critical machinery.
ALLEN-BRADLEY
Industrial Automation Components
High-quality PLCs, HMIs, and I/O modules for reliable control systems.
HONEYWELL
Controllers, I/O & Interface Modules
New parts to support DCS platforms and PLC installations.
Blog posts
-
Smart Factory Automation & Industrial Integration Services
Professional industrial integration enhances OEE, reduces waste, and future-proofs your production with scalable automation.
-
Industrial Automation 2026: Process Control & Plant Management
2026 process control & plant management systems drive efficiency, cut downtime, and boost safety. Expert...
-
Ab Plc Production Line Upgrade Boosts Oee And Cuts Downtime
Upgrade Legacy Lines To Ab Plc Control. Improve Oee, Reduce Downtime, And Scale Faster With...