Skip to content
Thousands of OEM Automation Parts In Stock
Fast Global Delivery with Reliable Logistics
Skip to product information
1 of 3

P3403893-0351 Bently Nevada Vibration Transmitter

Bulk Orders & Fast Shipping

Instant 10% Discount On Winter Banks Credit/Debit Cards EMI and CreditCard

Fast & Reliable Worldwide Shipping – Ready to Dispatch from Stock

In stock (17 units), ready to be shipped
  • Fast shipping
  • Return Policy
  • Lowest Price
  • Help Center 24/7

About the Product

Bently Nevada P3403893-0351 2 Wire Vibration Transmitter

Key Technical Specifications

  • Manufacturer & Model: Bently Nevada P3403893-0351 – 2 Wire Vibration Transmitter.
  • Output Signal: Provides a standard 4-20 mA current loop output for seamless PLC or DCS integration.
  • Power Supply: Loop-powered design accepts 12 to 35 VDC input voltage.
  • Frequency Response: Covers a range from 5 Hz to 6,000 Hz (+0, 3 dB) for comprehensive vibration monitoring.
  • Prox Out Linear Range: 1.4 mm (55 mils), beginning approximately 0.25 mm (10 mils) from the target surface.
  • Incremental Scale Factor: 7.87 mV/µm (200 mV/mil) ±6.5% typical; worst case ±10% over the linear range.
  • Temperature Stability: Scale factor remains within ±10% of 7.87 mV/µm across 0°C to +70°C (+32°F to +158°F).
  • Output Impedance: Prox Out offers a 10 kΩ output impedance, calibrated for a 10 MΩ load.
  • Minimum Target Size: Requires a target of at least 9.5 mm (0.375 inches) in diameter.
  • Leadwire Length: Maximum cable distance from the Proximitor Sensor output (BNC connector) is 3 meters (10 feet).

Installation and Mounting Guidance

  • Secure Mounting: Mount the transmitter casing directly to a rigid structural surface on the bearing housing. Use the proper mounting studs to ensure accurate vibration transmission.
  • Surface Preparation: Ensure the mounting interface is free of paint, scale, or debris to maintain a clear mechanical impedance path.
  • Cable Routing: Route the 2-wire shielded cable through grounded metallic conduit. Keep it away from high-voltage AC lines and variable frequency drives to avoid interference.
  • Shield Grounding: Connect the cable shield to the instrumentation earth ground at the monitoring panel end only. Leave the shield ungrounded at the transmitter to prevent ground loops.
  • Loop Voltage Check: Verify that the loop supply voltage remains between 12 VDC and 35 VDC at the transmitter terminals under maximum current load (20 mA).

Package Contents

  • Bently Nevada P3403893-0351 Vibration Transmitter unit (factory-sealed, brand new).
  • Standard transmitter housing with industrial-grade stainless steel casing.
  • Mounting stud for direct machine casing installation.
  • User manual with installation and wiring instructions.
  • Note: This package does not include calibration certificates or a printed 12-month warranty card.

Shipping and Delivery Information

  • Shipping Carriers: We ship this item via FedEx, UPS, or DHL for reliable global delivery.
  • Dispatch Time: We dispatch all orders within 5 business days after order confirmation.
  • Stock Status: We keep the Bently Nevada P3403893-0351 in stock and ready for immediate shipment.
  • Returns Policy: You may return this product within 30 days of receipt for a full refund.

Frequently Asked Questions (FAQ)

  • Q: What is the power supply range for the P3403893-0351?
    A: This loop-powered transmitter accepts 12 to 35 VDC. Always verify the voltage at the terminals under load.
  • Q: Does this transmitter work with standard PLC analog input cards?
    A: Yes, the 4-20 mA current loop interfaces directly with standard single-ended or differential analog input channels.
  • Q: What is the maximum cable length for the Proximitor output?
    A: The maximum cable distance from the Proximitor Sensor output (BNC connector) is 3 meters (10 feet).
  • Q: Is this unit suitable for hazardous area locations?
    A: Yes, it is approved for Non-Hazardous, Zone 2, or Div 2 hazardous area locations. The power supply requirement is 28 V.
  • Q: How should I ground the cable shield?
    A: Connect the shield to earth ground at the monitoring panel end only, leaving the transmitter end ungrounded to prevent ground loops.
  • Q: Do I need to recalibrate the transmitter after installation?
    A: No, each unit is factory-calibrated. The Bently Nevada P3403893-0351 is ready for immediate deployment.
  • Quick Quotes: Receive pricing and availability fast from our dedicated customer service team.
  • Delivery: Expedited, freight, and international shipping available worldwide.
  • Warranty: NexAuto offers a 12-month warranty on all parts purchased from us, in addition to any manufacturer coverage.
  • Returns: 30-day return policy for defective or mismatched parts, ensuring peace of mind.
  • Payment: Flexible options including major credit cards, PayPal, and bank transfers.
  • Custom Calibration: Provide your specifications, and we’ll handle the rest with precision.
View Product Details