Honeywell XNXXSG1SS Electrochemical Sensor Assembly

  • Brand & Manufacturer: Honeywell
  • Model Number: XNXXSG1SS
  • Product Type: Electrochemical (EC) Smart Sensor Assembly
  • Target Gas: Hydrogen (H₂) – Low range
  • Detection Range: 0 to 1,000 ppm (fixed, non-selectable)
  • Default Calibration Point: 500 ppm
  • Calibration Gas Range: 30 to 70% of full scale (300–700 ppm)
  • Lower Detectable Limit (LDL): 30 ppm
  • Response Time (T50): < 60 seconds
  • Response Time (T90): < 90 seconds
  • Accuracy: < ±8 ppm
  • Operating Temperature: -20°C to 55°C (-4°F to 131°F)
  • Housing Material: Stainless Steel
  • Shipping Weight: Approx. 4 kg

Key Features & Smart Design

  • Pre-configured smart sensor for immediate use with XNX and Series 3000 transmitters.
  • Hot-swappable – replace the XNXXSG1SS without removing system power.
  • Stainless steel construction withstands harsh industrial conditions.
  • Continuous toxic and oxygen monitoring for worker safety.
  • Fixed 0–1000 ppm range with reliable electrochemical response.

Technical Performance Details

  • Selectable Full Scale: Not applicable (fixed at 1000 ppm).
  • Default Range: 1000 ppm (Hydrogen, low range).
  • Calibration Gas Range: 30–70% of selected full scale (300–700 ppm).
  • Default Cal Point: 500 ppm for easy setup.
  • Response T50: Under 60 seconds – fast initial alarm.
  • Response T90: Under 90 seconds – full stabilization.
  • Accuracy: ±8 ppm ensures precise readings.
  • Lower Detectable Limit: 30 ppm – reliable at low concentrations.
  • Operating Temperature Range: -20°C to 55°C for versatile deployment.
  • Housing: Stainless steel (SS) for corrosion resistance.

Installation & Compatibility

  • Compatible with Honeywell XNX Universal Transmitter.
  • Also works with Series 3000 MkII and MkIII gas detector transmitters.
  • Smart sensor assembly installs directly into the transmitter cradle.
  • No special tools required – plug-and-play replacement.
  • Always power off the system if hot-swap is not preferred.
  • Refer to the transmitter manual for step-by-step sensor change.

Package Contents

  • 1 x Honeywell XNXXSG1SS Electrochemical Sensor Assembly
  • Pre-installed smart electronics with factory calibration
  • Protective shipping cap (remove before installation)
  • Instruction sheet (quick start guide)
  • No additional mounting hardware required

Shipping & Logistics

  • Shipping weight: approximately 4 kg per unit.
  • We ship via FedEx, UPS, or DHL – tracking provided.
  • Orders dispatch within 5 business days.
  • Stock availability: New, original, and in stock.
  • Returns accepted within 30 days of delivery (conditions apply).

Frequently Asked Questions (FAQ)

  • Is the XNXXSG1SS brand new and original?
    Yes, we supply 100% new, original Honeywell sensors with full factory specifications.
  • Can I use this sensor with my Series 3000 MkII transmitter?
    Absolutely. The XNXXSG1SS is fully compatible with XNX, Series 3000 MkII, and MkIII systems.
  • What is the default calibration gas value?
    The default cal point is 500 ppm, and you can use 30–70% of full scale for adjustment.
  • How long does shipping take?
    We dispatch within 5 business days via FedEx, UPS, or DHL. Delivery times vary by destination.
  • What is the response time for hydrogen detection?
    T50 is under 60 sec, and T90 is under 90 sec – fast and reliable.
  • Can I return the sensor if it doesn't fit?
    Yes, we accept returns within 30 days, provided the sensor is unused and in original packaging.
  • Is hot-swapping really safe?
    Yes, the smart design allows hot-swap, but always follow your site safety procedures.
  • What is the lower detectable limit for H₂?
    The LDL is 30 ppm, ensuring sensitivity at low hydrogen concentrations.

© 2026 NexAuto Technology Limited. All rights reserved.
Original Source: https://www.nex-auto.com/
Contact: sales@nex-auto.com | Phone: +86 153 9242 9628

  • Quick Quotes: Receive pricing and availability fast from our dedicated customer service team.
  • Delivery: Expedited, freight, and international shipping available worldwide.
  • Warranty: NexAuto offers a 12-month warranty on all parts purchased from us, in addition to any manufacturer coverage.
  • Returns: 30-day return policy for defective or mismatched parts, ensuring peace of mind.
  • Payment: Flexible options including major credit cards, PayPal, and bank transfers.
  • Custom Calibration: Provide your specifications, and we’ll handle the rest with precision.
View Product Details