Moog D662-4978 Servo Valve
Specification Details Rated Flow 150 to 250 l/min (39.6 to 66 gpm) at Δp 5 bar (75 psi) per land Maximum Flow 600 l/min (158 gpm) Pressure Rating - Ports P, A, B 350 bar (5,000 psi) Pressure Rating - Port T (External Y)... -
Vendor: More Brands
MTL - MTL5040 Transmitter Power Supply
MTL5040 Dual-Channel 4-20mA Isolator & Transmitter Power Supply Core Function: Powers hazardous-area transmitters (Channel 1) and replicates signals to safe-area (Channel 2) with full electrical isolation. Technical Specifications Channel 1 (Transmitter Power): • Output: 16.5V @20mA to transmitter • Input Range: 0-24mA (4-20mA nominal)... -
Vendor: More Brands
MTL 4073 Eaton MTL 100% Genuine New Signal Converter
Product Introduction The MTL-4073 is a sophisticated temperature transmitter designed for hazardous area applications. It converts signals from thermocouples or RTDs into a stable 4-20mA output with configurable parameters for precise process monitoring. Key Features Supports 8 thermocouple types and 2/3/4-wire RTD configurations Software-configurable... -
Vendor: More Brands
MTL Fieldbus Networks Multiplexer Receiver MTL838C
MTL838C Modbus Interface for Hazardous Area Monitoring Core Functionality Converts signals from 32 hazardous area inputs to Modbus protocol. Works as Modbus slave device for safe area integration. Technical Details Input capacity: 32 analog channels Modbus version: RTU protocol Address range: 1-247 (programmable) Operating... -
Vendor: More Brands
MTL Instruments - MTL5516C Proximity Switch Interface
MTL5516C NAMUR Proximity Switch Interface (Replaces MTL3013) Core Specifications Channels: 2 galvanically isolated NAMUR inputs Input type: NAMUR proximity sensors (EN 60947-5-6) Output type: Relay contacts (NO/NC configurable) Supply voltage: 20-35V DC (loop-powered) Safety limits: 10.5V/14mA max (ATEX/IECEx compliant) Temperature range: -20°C to +60°C... -
Vendor: More Brands
MTL Instruments | Analog Transmitter MTL831C
MTL831C Analog Transmitter for Hazardous Areas Key Features Monitor 16 inputs in Zone 0 hazardous locations. Works with THC, millivolt, RTD, and potentiometer signals. Intrinsically safe design. Technical Specifications Input types: 16 channels for THC (0-50mV) or millivolt (-10mV to +100mV) RTD support: 2/3/4-wire... -
Vendor: More Brands
MTL Instruments | Digital Isolator | MTL3052
Product Introduction The MTL3052 is an intrinsically safe (IS) interface barrier designed for digital signal transmission in hazardous areas. It operates at higher frequencies than the MTL3042, making it ideal for MTL800 Series multiplexer systems. The unit ensures safe data highway and transmitter communication... -
Vendor: More Brands
MTL Instruments | Isolating Driver MTL4546Y
MTL4546Y Hazardous Area 4-20mA to I/P Converter with HART Support Core Specifications Parameter Specification Input Signal 4-20mA (1-24mA under/over-range) Output Capacity 800Ω max load (16V @ 20mA) HART Bandwidth 500Hz - 10kHz Accuracy @20°C ±20μA Response Time 100ms to ±200μA Safety & Protection Features... -
Vendor: More Brands
MTL Instruments | MTL Pulse Isolator - MTL5522
MTL5522 Solenoid/Alarm Driver for Hazardous Areas Essential Protection Loop-powered driver for Zone 0/Div.1 hazardous locations. Controls IS loads from safe areas. Key Specifications • Input Voltage: 20-35V DC • Output Voltage: 10.7V (min) to 24V (max) • Current Limit: 70mA minimum • Response Time:... -
Vendor: More Brands
MTL Instruments | MTL5018AC Relay Interface
MTL5018AC Dual-Channel Relay Interface (AC Powered) Key Features AC-Powered - 85-265V AC operation Two 2A relays with changeover contacts Independent phase reversal per channel Visual line fault diagnostics Technical Specifications Input Characteristics Type: NAMUR/DIN 19234 compliant Voltage: 7-9V via 1kΩ ±10% ON Threshold: >2.1mA... -
Vendor: More Brands
MTL Instruments | MTL5053 Fieldbus Isolator
MTL5053 Fieldbus Isolator for Hazardous Areas Extends 31.25kbit/s H1 fieldbus networks into Zone 0 with integrated power supply Key Features Certification Zone 0, IIC, T4-T6 certified Power Supply 18.4V ±2% (80mA max) Communication 31.25kbit/s H1 fieldbus Installation DIN rail with 10mm spacing Technical Specifications... -
Vendor: More Brands
MTL Instruments | MTL5582B RTD Resistance Isolator
MTL5582B RTD Resistance Isolator for Hazardous Zones Core Technical Specifications Input RTD type: 2/3/4-wire (switch-selectable, factory-set for 3-wire) Resistance range: 10Ω to 400Ω (supports Pt100, DIN 43760) Excitation current: 200µA (prevents RTD self-heating) Output range: 10Ω to 400Ω (100µA to 5mA source) Accuracy drift:... -
Vendor: More Brands
MTL Instruments | Temperature Converter MTL4575
MTL4575 Hazardous Area Temperature Transmitter Key Features Converts temperature signals to 4-20mA for safe area use. Works with all major thermocouples and RTDs. PC-configurable with alarm output. Technical Specifications Input Range: -75mV to +75mV or 0-1000Ω Output Signal: 4-20mA into 600Ω max Accuracy: ±0.05%... -
Vendor: More Brands
MTL Switch/Proximity Detector Interface Isolator MTL4016
MTL4016 Dual-Channel Relay Isolator with Dual Outputs Dual-Channel, Dual-Output Design • 2 hazardous area inputs control 4 safe-area relays • Independent phase reversal per channel • Line fault detection for both channels • Earth fault monitoring (with MTL4220) Key Specifications Input Voltage: 7-9V DC... -
Vendor: More Brands
MTL | Repeater Power Supply | MTL3041
Product Introduction The MTL3041 provides a fully-floating DC supply for 2-wire 4-20mA transmitters in hazardous areas. Its 17.5V output (at 20mA) powers most transmitter loops while maintaining complete electrical isolation. This barrier accurately replicates current in a separate floating circuit for safe-area loads. The... -
Vendor: More Brands
MTL3011 Eaton MTL Hazardous Area Switch Interface
Hazardous Area Switch Interface The MTL3011 safely connects hazardous-area proximity detectors or switches to safe-area control systems. Featuring a relay output and intelligent fault detection, it provides reliable operation in critical safety applications. Key Features Built-in line-fault detection for broken/short-circuited wiring Configurable phase-reverse control... -
Vendor: More Brands
MTL3045 Isolating Driver - Eaton MTL
MTL3045 Signal Isolator for Hazardous Areas The MTL3045 provides precision isolation for 4-20mA/0-20mA control signals to hazardous-area devices. With 16V output capability and minimal voltage drop, it's ideal for driving I/P converters, actuators, and other loads up to 800Ω. Key Features Maintains ±20μA accuracy... -
Vendor: More Brands
MTL3046B Repeater Power Supply | MTL
Product Introduction The MTL3046B barrier safely interfaces smart transmitters in hazardous areas with control systems. This advanced unit supports both 4-20mA analog signals and digital communications simultaneously. It replaces the MTL3046 while offering enhanced compatibility with most modern smart transmitters. Engineers can calibrate and... -
Vendor: More Brands
MTL4015 Detector Interface Unit Eaton MTL
Product Introduction The MTL4015 is a single-channel interface that connects hazardous-area sensors to two independent safe-area systems. Ideal for critical applications requiring dual signaling (e.g., control + shutdown systems). Key Features Dual relay outputs for redundant system integration Phase-reversal switch for alarm state configuration... -
Vendor: More Brands
MTL4017 Detector Interface MTL Instruments
Product Introduction The MTL4017 is a two-channel switch/proximity detector interface designed for hazardous areas. It safely controls loads through relays while monitoring for line faults. This robust solution works with both switches and proximity detectors in explosive environments. Key Features Two isolated channels for...