Vendor: More Brands
MTL5025 | Safe Interface | MTL Instruments
MTL5025 Intrinsically Safe Interface for Hazardous Areas Key Technical Parameters Output voltage range: 8.6V to 24V Maximum output current: 45mA Input voltage range: 20V to 35V DC Power consumption: 1.6W at 24V Operating temperature: -20°C to +60°C Response time: under 100ms Load resistance: up... -
Vendor: More Brands
MTL5031 | Vibration Signal Repeater | MTL
MTL5031 Hazardous Area Vibration Signal Repeater Core Technical Specifications Input Impedance: 10kΩ ±1%/+2% Output Impedance: <20Ω Frequency Range: 0Hz-20kHz (-3dB at 43kHz) DC Accuracy: ±100mV at 20°C AC Accuracy: ±1% (0Hz-1kHz), -5%/+1% (1kHz-10kHz) Transducer Supply: -20V to -0.5V Phase Lag: <14μs (equivalent to -1°... -
Vendor: More Brands
MTL5032 | Hazardous Area Pulse Isolator for Switch
MTL5032 Hazardous Area Pulse Isolator for Switch & Sensor Signals Key Technical Parameters Input voltage range: 20-35V DC Frequency response: 0-50kHz Pulse width handling: 10μs minimum Operating temperature: -20°C to +60°C Isolation voltage: 1500V AC Response time: <1ms Housing material: Flame-retardant polycarbonate Weight: 120g... -
Vendor: More Brands
MTL5041 MTL - Repeater Power Supply
MTL5041 Intrinsically Safe 4-20mA Isolator for Zone 0 Core Specifications Channels: 1-channel 4-20mA loop repeater Input: 0-24mA (hazardous area) Output: 4-20mA (safe area, 0-24mA over-range) Accuracy: ±20µA (±0.1% FS) at 20°C Response Time: 250µs to 90% final value Load Capacity: 0-1kΩ safe-area load Certifications... -
Vendor: More Brands
MTL5042 | MTL - Hazardous Area Signal Repeater
MTL5042 Hazardous Area Signal Repeater with HART Support Key Technical Specifications Input current range: 0-24mA Output current range: 4-20mA (0-24mA over-range) Transfer accuracy: ±10μA at 20°C Temperature stability: ±0.5μA/°C Transmitter supply voltage: 16.5V at 20mA Response time: 40μs to 90% value Digital bandwidth: 10Hz-12kHz... -
Vendor: More Brands
MTL5044 Power Supply | Eaton MTL
MTL5044 Dual-Channel Transmitter Power Supply & Signal Isolator ⚡ Core Function: Powers two 2-wire 4-20mA transmitters in hazardous areas while isolating and replicating signals to safe-area loads. Key Specifications Hazardous Area (Input): • Transmitter Voltage: 16.5V @20mA • Signal Range: 0-24mA • Certification: Zone... -
Vendor: More Brands
MTL5046 Isolating Driver | MTL Instruments
MTL5046 Isolating Driver Hazardous Area Signal Conditioner with 4-20mA Isolation Key Feature: Safe signal transmission between Zone 0 hazardous areas and safe areas with 500Hz-10kHz bandwidth Technical Specifications Manufacturer MTL Instruments Channels 1 channel isolated Input Range 4-20mA (1-24mA overrange) Bandwidth 500Hz to 10kHz... -
Vendor: More Brands
MTL5049 MTL Instruments - Isolating Driver
MTL5049 Dual-Channel 4-20mA Isolator for Hazardous Areas Core Specifications Channels: 2 isolated 4-20mA Input Range: 0-24mA (4-20mA nominal) Output Load: ≤550Ω (11V@20mA) Accuracy: ±20μA @20°C Response Time: 250μs to 90% value Isolation: 28V, 300Ω, 93mA (Um=250V) Wiring Configuration Terminal Function 1, 2 Channel 1... -
Vendor: More Brands
MTL5061 Detector Interface | MTL Instruments
MTL5061 Dual-Channel Fire/Smoke Detector Interface Loop-powered interface for hazardous area detectors Key Features Safety • Reverse polarity protection• Optional earth fault detection• Zone 0, IIC, T4-T6 certified Performance • 1-40mA current range• 30ms response time• ±400μA accuracy Technical Specifications Parameter Value Output Voltage 28V... -
Vendor: More Brands
MTL5081 MTL Instruments | Thermocouple Isolator
MTL5081 Thermocouple Isolator for Hazardous Areas Key Specifications • Input/Output Range: 0 to ±50mV (±55mV overrange) • Accuracy: ±5µV or 0.05% (whichever is greater) • Temp Drift: ±(2µV + 0.002%/°C) • Response Time: 150µs to 90% value • Bandwidth: DC to 4kHz • Output... -
Vendor: More Brands
MTL5511 Switch/Proximity Detector Interface
MTL5511 Switch/Proximity Detector Interface Overview The MTL5511 safely connects hazardous-area sensors to control systems. This interface module works with NAMUR-compliant devices in explosive environments. It provides reliable signal conversion between Zone 0 and safe areas. Key Features Approved for use in hazardous locations Compact... -
Vendor: More Brands
MTL5514D Safe Industrial Switching for Hazardous Areas
MTL5514D - Safe Industrial Switching for Hazardous Areas Reliable Sensor Interface The MTL5514D connects hazardous area sensors to control systems. It works with switches and proximity detectors in explosive environments. Two relay outputs provide safe area control. Key Technical Specs Input channels: 1 (NAMUR... -
Vendor: More Brands
MTL5521 Solenoid/Alarm Driver | MTL Instruments
MTL5521 Solenoid/Alarm Driver Hazardous Area Control Solution Galvanic barrier for safe operation of solenoids and alarms in explosive environments. ATEX certified for hazardous locations. Technical Specifications • Power Supply: 20-35V DC • Safety Output: 10.5V max, 108mA max • Signal Type: Loop powered digital... -
Vendor: More Brands
MTL5524 - Hazardous Area On/Off Control Module
MTL5524 Hazardous Area On/Off Control Module Key Features Safe control of Zone 0 devices using simple safe-area signals. Drives solenoids, alarms, and low-power devices with phase reversal option. Technical Specifications Output Voltage: 13.6V (min) to 24V (max)Current Limit: 48mA minimumOff-State Leakage: <4VResponse Time: <100msInput... -
Vendor: More Brands
MTL5532 Pulse Isolator | MTL Instruments
MTL5532 Pulse Isolator for Hazardous Areas Core Protection Features Single-channel isolator for Zone 0/Div.1 hazardous locations. Compliant with NAMUR/BS EN 60947-5-6:2001 standards. Technical Specifications Channels: 1 fully floating Sensor Compatibility: Switch/proximity detector (2-3 wire) Hazardous Rating: Zone 0, IIC, T6 (Switch) Alarm Output: Relay... -
Vendor: More Brands
MTL5541 Repeater Power Supply for Hazardous Areas
MTL5541 Repeater Power Supply for Hazardous Areas Essential Protection The MTL5541 safely transfers signals from Zone 0 hazardous areas. It provides clean power to transmitters while maintaining signal integrity. Precision Performance Transfer accuracy: ±15μA at 20°C Temperature stability: <0.8μA/°C drift Fast response: 50μs to... -
Vendor: More Brands
MTL5541S Repeater Power Supply Isolator
MTL5541S Repeater Power Supply Isolator Core Functionality DIN-rail mounted isolator for precise signal transfer in hazardous areas. Provides safe power to transmitters with minimal signal distortion. Key Specifications • Input/Output: 1 channel analog (0-24mA) • Ripple: <50µA peak-to-peak • Accuracy: ±15µA at 20°C •... -
Vendor: More Brands
MTL5544D Repeater Power Supply MTL Instruments
MTL5544D Repeater Power Supply with HART Support Dual Output Signal Repeater Provides isolated power for hazardous area transmitters while repeating the 4-20mA signal to two safe area loads. Maintains HART communication capability. Key Specifications Input: 1 channel 4-20mA (2/3-wire transmitters) Outputs: 2 isolated 4-20mA... -
Vendor: More Brands
MTL5573 MTL - Temperature Transmitter
MTL5573 Temperature Transmitter for Hazardous Areas Core Specifications Input Channels 1 channel (Zone 0, IIC, Div.1 Groups A-D) Sensor Types Thermocouples & RTDs Output Signal 4-20mA into 600Ω max Technical Parameters RTD Excitation 200μA nominal CJC Accuracy ≤1.0°C error Noise Rejection 120dB CMRR /... -
Vendor: More Brands
MTL5575 Temperature Converter MTL Instruments
MTL5575 Temperature Converter for Hazardous Areas Core Functionality Primary Function Converts hazardous-area temperature signals to 4-20mA output Sensor Compatibility All thermocouple types + 2/3/4-wire RTDs Technical Specifications Input Types Thermocouples (with CJC compensation) RTDs (Pt100, Ni100, etc.) Output Signal 4-20mA current loop Alarm Output...